메뉴 건너뛰기




Volumn 72, Issue 2, 1992, Pages 261-270

A simple transmission X-ray microtomography instrument

Author keywords

[No Author keywords available]

Indexed keywords


EID: 4243743336     PISSN: 0168583X     EISSN: None     Source Type: Journal    
DOI: 10.1016/0168-583X(92)95242-J     Document Type: Article
Times cited : (11)

References (34)
  • 12
    • 84913443118 scopus 로고    scopus 로고
    • Rigaku X-ray diffractometer system, Geigerflex CN2029 D/Max IIA, Rigaku USA Inc., 3 Electronics Avenue, Massachusetts, MA 01923.
  • 15
    • 84913443117 scopus 로고    scopus 로고
    • The micrometer adjustable tantalum slits were manufactured by Sietronics Pty. Ltd. P.O. Box 84, Hawker, ACT 2614, Australia.
  • 16
    • 84913443116 scopus 로고    scopus 로고
    • Unislide Catalogue GB 86, Time and Precision Engineering Ltd., Stroudley Road, Daneshill East, Basingstoke RG24 0UG, England.
  • 18
    • 84913443114 scopus 로고    scopus 로고
    • A copy of the EPROM stage drive program is available from the authors on request.
  • 19
    • 84913443113 scopus 로고    scopus 로고
    • Mathematically, it is required that the linear attenuation coefficient μ(x,y) be continuous and finite within a circle of radius R, called the image circle Ω, and vanishes outside of Ω.
  • 31
    • 77951884825 scopus 로고
    • Some Aspects of Non-Destructive Testing Using Computerised Tomography
    • Chisholm Institute of Technology, unpublished
    • (1988) M. App. Sc. Thesis
    • Shadbolt1
  • 32
    • 84913468564 scopus 로고
    • Tables of Photon-Interaction Cross Sections Derived from the LLNL Evaluated Photon Data Library (EPDL), Z = 1 to 50
    • −1 was calculated from the mixture rule (see ref. [21]) using a log-log interpolation scheme to obtain the cross sections at 17.445 keV; see, Lawrence Livermore National Laboratory
    • (1989) UCRL-50400 , vol.6
    • Cullen1    Chen2    Hubbell3    Perkins4    Plechaty5    Rathkopf6    Scofield7
  • 33
    • 84913443112 scopus 로고    scopus 로고
    • The primary beam X-ray Siroflux system is manufactured by Sietronics Pty. Ltd. (see ref. [15]). It incorporates a channel-cut silicon monochromator that allows a high degree of monochromaticity, spectral brightness and collimation to be achieved with a laboratory X-ray source.
  • 34
    • 84913443111 scopus 로고    scopus 로고
    • 7 cps can be achieved with organic scintillation materials. See for example, the high speed X-ray detector available from Siemens Analytical X-Ray Instruments Inc., 6300 Enterprise Lane, Madison, WI 53719.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.