메뉴 건너뛰기




Volumn 58-59, Issue , 2001, Pages 707-712

Non destructive three dimensional analysis of the packing of a binary beryllium pebble bed

Author keywords

Computer aided microtomography; Infiltrated bed; Thermal mechanical behaviour

Indexed keywords

ATTENUATION; BERYLLIUM COMPOUNDS; COMPUTERIZED TOMOGRAPHY; MICROCRACKS; NEUTRONS; SYNCHROTRON RADIATION; THERMAL EFFECTS; X RAY ANALYSIS;

EID: 4243243773     PISSN: 09203796     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0920-3796(01)00539-7     Document Type: Article
Times cited : (11)

References (8)
  • 1
    • 0003522931 scopus 로고
    • Kernforschungszentrum Karlsruhe Report, KfK 5429, Karlsruhe, November
    • M. Dalle Donne et al., "European DEMO BOT Solid Breeder Blanket", Kernforschungszentrum Karlsruhe Report, KfK 5429, Karlsruhe, November 1994.
    • (1994) European DEMO BOT Solid Breeder Blanket
    • Dalle Donne, M.1
  • 2
    • 33847577479 scopus 로고    scopus 로고
    • Design Description Document WBS 1.6B, Tritium Breeding Blanket System ITER Document G 16 DDD 2 98-06-10 WO.4
    • K Ioki, M. Ferrari (Eds.). ITER Final Design Report, Design Description Document WBS 1.6B, Tritium Breeding Blanket System. ITER Document G 16 DDD 2 98-06-10 WO.4.
    • ITER Final Design Report
    • Ioki, K.1    Ferrari, M.2
  • 3
    • 33847588020 scopus 로고    scopus 로고
    • Mechanical behaviour of monosized and binary beryllium pebble beds
    • Karlsruhe, 15-17 September Forschungszentrum Karlsruhe Report FZKA 6462, April
    • J. Reimann, M. Behnke, Mechanical behaviour of monosized and binary beryllium pebble beds, in Proceedings of the 4th IEA International Workshop on Beryllium Technology for Fusion, Karlsruhe, 15-17 September 1999. Forschungszentrum Karlsruhe Report FZKA 6462, April 2000, p. 143-154.
    • (1999) Proceedings of the 4th IEA International Workshop on Beryllium Technology for Fusion , pp. 143-154
    • Reimann, J.1    Behnke, M.2
  • 6
    • 0036525889 scopus 로고    scopus 로고
    • Segmentation of cancellous bones from high resolution computed tomography images: Influence on trabecular bone measurements
    • A. Elmoutaouakkil, F. Peyrin, J. Elfaki, A.M. Laval-Jeantet, Segmentation of cancellous bones from high resolution computed tomography images: influence on trabecular bone measurements, submitted for publication in IEEE Trans. Med. Imag.
    • IEEE Trans. Med. Imag.
    • Elmoutaouakkil, A.1    Peyrin, F.2    Elfaki, J.3    Laval-Jeantet, A.M.4
  • 7
    • 0032706138 scopus 로고    scopus 로고
    • Description of a synchrotron radiation microtomography device for 3-D trabecular bone imaging
    • M. Salome-Pateyron, et al., Description of a synchrotron radiation microtomography device for 3-D trabecular bone imaging, Med. Phys. 26 (10) (1999) 2194-2204.
    • (1999) Med. Phys. , vol.26 , Issue.10 , pp. 2194-2204
    • Salome-Pateyron, M.1
  • 8
    • 0022808786 scopus 로고
    • A computational approach to edge detection
    • J.F. Canny, A computational approach to edge detection, IEEE Trans. PAMI 8 (10) (1986) 679-698.
    • (1986) IEEE Trans. PAMI , vol.8 , Issue.10 , pp. 679-698
    • Canny, J.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.