메뉴 건너뛰기




Volumn 32, Issue 4, 2004, Pages 423-431

On-line preconcentration system by coprecipitation with lanthanum hydroxide using packed-bed filter for the determination of tellurium in water by ICP-OES with USN

Author keywords

ICP OES; On line coprecipitation; Te in water; Tellurium determination

Indexed keywords

ADSORPTION; CALIBRATION; CONCENTRATION (PROCESS); INDUCTIVELY COUPLED PLASMA; LANTHANUM COMPOUNDS; ONLINE SYSTEMS; PHOTOELECTRICITY; PRECIPITATION (CHEMICAL); VULCANIZATION;

EID: 4243198258     PISSN: 10739149     EISSN: None     Source Type: Journal    
DOI: 10.1081/CI-120037674     Document Type: Article
Times cited : (11)

References (22)
  • 2
    • 84987453829 scopus 로고
    • Adsorptive stripping voltammetric determination of trace tellurium in the presence of oxine
    • Wang, J.; Lu, J. Adsorptive stripping voltammetric determination of trace tellurium in the presence of oxine. Electroanalysis 1994, 6, 405-408.
    • (1994) Electroanalysis , vol.6 , pp. 405-408
    • Wang, J.1    Lu, J.2
  • 3
    • 0032584268 scopus 로고    scopus 로고
    • Simultaneous determination of the speciation of selenium and tellurium in geological matrices by use of an iron(III)-modified chelating resin and cathodic stripping voltammetry
    • Ferri, T.; Rossi, S.; Sangiorgio, V. Simultaneous determination of the speciation of selenium and tellurium in geological matrices by use of an iron(III)-modified chelating resin and cathodic stripping voltammetry. Anal. Chim. Acta 1998, 361, 113-123.
    • (1998) Anal. Chim. Acta , vol.361 , pp. 113-123
    • Ferri, T.1    Rossi, S.2    Sangiorgio, V.3
  • 4
    • 0005227199 scopus 로고
    • Preconcentration of tellurium(IV) by a modified chelating resin
    • Baldelli, M.; Ferri, T.; Liberatori, A.; Petronio, V. Preconcentration of tellurium(IV) by a modified chelating resin. Analysis 1994, 22, 147-151.
    • (1994) Analysis , vol.22 , pp. 147-151
    • Baldelli, M.1    Ferri, T.2    Liberatori, A.3    Petronio, V.4
  • 5
    • 11544298356 scopus 로고
    • Determination of some hydride-forming elements in urine by resin complexation and inductively coupled plasma atomic spectroscopy
    • Fodor, P.; Barnes, R. Determination of some hydride-forming elements in urine by resin complexation and inductively coupled plasma atomic spectroscopy. Spectrochim. Acta Part B 1983, 388, 229-243.
    • (1983) Spectrochim. Acta Part B , vol.388 , pp. 229-243
    • Fodor, P.1    Barnes, R.2
  • 6
    • 0040395735 scopus 로고
    • Simultaneous determination, by hydride generation and inductively coupled plasma atomic emission spectrometry of arsenic, antimony, selenium and tellurium in silicate rocks containing the noble metals and sulphide ores
    • Halicz, L.; Russell, G. Simultaneous determination, by hydride generation and inductively coupled plasma atomic emission spectrometry of arsenic, antimony, selenium and tellurium in silicate rocks containing the noble metals and sulphide ores. Analyst 1986, 111, 15-18.
    • (1986) Analyst , vol.111 , pp. 15-18
    • Halicz, L.1    Russell, G.2
  • 7
    • 0000603745 scopus 로고
    • Application of flow injection inductively coupled plasma mass spectrometry to the simultaneous determination of arsenic, antimony, bismuth, selenium and tellurium in steels
    • Coedo, A.; Dorado, M. Application of flow injection inductively coupled plasma mass spectrometry to the simultaneous determination of arsenic, antimony, bismuth, selenium and tellurium in steels. J. Anal. Atomic Spectrom. 1994, 9, 1111-1115.
    • (1994) J. Anal. Atomic Spectrom. , vol.9 , pp. 1111-1115
    • Coedo, A.1    Dorado, M.2
  • 8
    • 0028773370 scopus 로고
    • Determination of tellurium in urine by isotope dilution gas chromatography/mass spectrometry using (4-fluorophenyl) magnesium bromide as a derivatizing agent and comparison with electrothermal atomic absorption spectrometry
    • Aggarwal, S.; Kinter, M.; Nicholson, J.; Herold, D. Determination of tellurium in urine by isotope dilution gas chromatography/mass spectrometry using (4-fluorophenyl) magnesium bromide as a derivatizing agent and comparison with electrothermal atomic absorption spectrometry. Anal. Chem. 1994, 66, 1316-1322.
    • (1994) Anal. Chem. , vol.66 , pp. 1316-1322
    • Aggarwal, S.1    Kinter, M.2    Nicholson, J.3    Herold, D.4
  • 9
    • 0042544842 scopus 로고
    • Electrothermal atomic absorption spectrometric determination of ultratrace amounts of tellurium using a palladium-coated L'Vov platform after separation and concentration by hydride generation and liquid anion exchange
    • Grotti, M.; Mazzucotelli, A. Electrothermal atomic absorption spectrometric determination of ultratrace amounts of tellurium using a palladium-coated L'Vov platform after separation and concentration by hydride generation and liquid anion exchange. J. Anal. Atomic Spectrom. 1995, 10, 325-327.
    • (1995) J. Anal. Atomic Spectrom. , vol.10 , pp. 325-327
    • Grotti, M.1    Mazzucotelli, A.2
  • 10
    • 0029504630 scopus 로고
    • Extraction-atomic absorption method for the determination of arsenic, selenium and tellurium in geological samples
    • Torgov, V.; Vail, G.; Demidova, M.; Yatsenko, V. Extraction-atomic absorption method for the determination of arsenic, selenium and tellurium in geological samples. Chem. Geol. 1995, 124, 101-107.
    • (1995) Chem. Geol. , vol.124 , pp. 101-107
    • Torgov, V.1    Vail, G.2    Demidova, M.3    Yatsenko, V.4
  • 11
    • 37049070477 scopus 로고
    • Determination of arsenic and tellurium by hydride generation atomic spectrometry: Minimizing interferences from nickel, cobalt and copper by using an alkaline sample solution
    • Wickstrom, T.; Lund, W.; Bye, V. Determination of arsenic and tellurium by hydride generation atomic spectrometry: minimizing interferences from nickel, cobalt and copper by using an alkaline sample solution. Analyst 1995, 120, 2695-2698.
    • (1995) Analyst , vol.120 , pp. 2695-2698
    • Wickstrom, T.1    Lund, W.2    Bye, V.3
  • 12
    • 0037417138 scopus 로고    scopus 로고
    • Hydride generation atomic fluorescence spectrometric determination of ultratraces of selenium and tellurium in cow milk
    • Cava-Montesinos, P.; Cervera, M.; Pastor, A.; De la Guardia, V. Hydride generation atomic fluorescence spectrometric determination of ultratraces of selenium and tellurium in cow milk. Anal. Chim. Acta 2003, 481, 291-300.
    • (2003) Anal. Chim. Acta , vol.481 , pp. 291-300
    • Cava-Montesinos, P.1    Cervera, M.2    Pastor, A.3    De La Guardia, V.4
  • 13
    • 0000207227 scopus 로고
    • Ultrasonic nebulization in inductively coupled atomic emission spectrometry
    • Gali, P.; Oddo, N. Ultrasonic nebulization in inductively coupled atomic emission spectrometry. Microchem. J. 1992, 46, 327-334.
    • (1992) Microchem. J. , vol.46 , pp. 327-334
    • Gali, P.1    Oddo, N.2
  • 14
    • 57249095533 scopus 로고    scopus 로고
    • Evaluation of various commercially available nebulization devices for inductively coupled plasma atomic emission spectrometry
    • Hoenig, M.; Baeten, H.; Vanhenternrijk, S.; Ploegaerts, V.; Bertholet, T. Evaluation of various commercially available nebulization devices for inductively coupled plasma atomic emission spectrometry. Analysis 1997, 25, 13-19.
    • (1997) Analysis , vol.25 , pp. 13-19
    • Hoenig, M.1    Baeten, H.2    Vanhenternrijk, S.3    Ploegaerts, V.4    Bertholet, T.5
  • 15
    • 0031168112 scopus 로고    scopus 로고
    • Microwave digestion and ultrasonic nebulization for determination of boron in animal tissues by inductively coupled plasma atomic emission spectrometry with internal standardization and addition of mannitol
    • Sun, D.; Waters, J.; Mawhinneg, T. Microwave digestion and ultrasonic nebulization for determination of boron in animal tissues by inductively coupled plasma atomic emission spectrometry with internal standardization and addition of mannitol. J. Anal. Atomic Spectrom. 1997, 12, 675.
    • (1997) J. Anal. Atomic Spectrom. , vol.12 , pp. 675
    • Sun, D.1    Waters, J.2    Mawhinneg, T.3
  • 16
    • 0346864471 scopus 로고
    • Determination of ultra-trace amounts of selenium(IV) by flow injection hydride generation atomic absorption spectrometry with on-line preconcentration by coprecipitation with lanthanum hydroxide
    • Tao, G.; Hansen, E. Determination of ultra-trace amounts of selenium(IV) by flow injection hydride generation atomic absorption spectrometry with on-line preconcentration by coprecipitation with lanthanum hydroxide. Analyst 1994, 119, 333-337.
    • (1994) Analyst , vol.119 , pp. 333-337
    • Tao, G.1    Hansen, E.2
  • 17
    • 0029879990 scopus 로고    scopus 로고
    • Determination of ultra-trace amounts of selenium (IV) by flow injection hydride generation atomic absorption spectrometry with online preconcentration by co-precipitation with lanthanum hydroxide. Part II. On-line addition of co-precipitating agent
    • Nielsen, S.; Sloth, J.; Hansen, E. Determination of ultra-trace amounts of selenium (IV) by flow injection hydride generation atomic absorption spectrometry with online preconcentration by co-precipitation with lanthanum hydroxide. Part II. On-line addition of co-precipitating agent. Analyst 1996, 121, 31-35.
    • (1996) Analyst , vol.121 , pp. 31-35
    • Nielsen, S.1    Sloth, J.2    Hansen, E.3
  • 19
    • 0026505837 scopus 로고
    • On line preconcentration system for inductively coupled plasma atomic emission spectrometry with quinolin-8-ol and Amberlite XAD-2-resin
    • Porta, V.; Sarzanini, C.; Mentasti, E.; Abollino, O. On line preconcentration system for inductively coupled plasma atomic emission spectrometry with quinolin-8-ol and Amberlite XAD-2-resin. Anal. Chim. Acta 1992, 255, 237-244.
    • (1992) Anal. Chim. Acta , vol.255 , pp. 237-244
    • Porta, V.1    Sarzanini, C.2    Mentasti, E.3    Abollino, O.4
  • 20
    • 0036360559 scopus 로고    scopus 로고
    • Determination of lead in drinking water by ICP-AES with ultrasonic nebulization and flow-injection on-line preconcentration using an amberlite XAD-16 resin
    • Wuilloud, R.; Acevedo, H.; Vazquez, F.; Martinez, L. Determination of lead in drinking water by ICP-AES with ultrasonic nebulization and flow-injection on-line preconcentration using an amberlite XAD-16 resin. Anal. Lett. 2002, 35, 1649-1665.
    • (2002) Anal. Lett. , vol.35 , pp. 1649-1665
    • Wuilloud, R.1    Acevedo, H.2    Vazquez, F.3    Martinez, L.4
  • 21
    • 0035848910 scopus 로고    scopus 로고
    • On-line preconcentration system for bismuth determination in urine by flow injection hydride generation inductively coupled plasma atomic emission spectrometry
    • Moyano, S.; Wuilloud, R.; Olsina, R.; Gásquez, J.; Martinez, L. On-line preconcentration system for bismuth determination in urine by flow injection hydride generation inductively coupled plasma atomic emission spectrometry. Talanta 2001, 54, 211-219.
    • (2001) Talanta , vol.54 , pp. 211-219
    • Moyano, S.1    Wuilloud, R.2    Olsina, R.3    Gásquez, J.4    Martinez, L.5
  • 22
    • 0035057784 scopus 로고    scopus 로고
    • On-line preconcentration system using a packed-bed filter for the determination of lead in tap water by inductively coupled plasma atomic emission spectrometry with ultrasonic nebulization
    • Wuilloud, R.; Salonia, J.; Gásquez, J.; Olsina, R.; Martinez, L. On-line preconcentration system using a packed-bed filter for the determination of lead in tap water by inductively coupled plasma atomic emission spectrometry with ultrasonic nebulization. Anal. Sci. 2001, 17, 457-459.
    • (2001) Anal. Sci. , vol.17 , pp. 457-459
    • Wuilloud, R.1    Salonia, J.2    Gásquez, J.3    Olsina, R.4    Martinez, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.