메뉴 건너뛰기




Volumn 7, Issue 2, 2008, Pages 125-132

Development of a novel post-processing treatment planning platform for 4D radiotherapy

Author keywords

4D radiotherapy; Deformable registration; Organ motion; Treatment planning

Indexed keywords

ABDOMINAL CANCER; ARTICLE; AUTOMATION; CANCER RADIOTHERAPY; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC IMAGING; DOSIMETRY; FOUR DIMENSIONAL IMAGING; HISTOGRAM; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; KIDNEY; LIVER; LUNG CANCER; RADIATION DOSE DISTRIBUTION; TREATMENT PLANNING;

EID: 42349104312     PISSN: 15330346     EISSN: None     Source Type: Journal    
DOI: 10.1177/153303460800700205     Document Type: Article
Times cited : (9)

References (40)
  • 1
    • 0003418877 scopus 로고    scopus 로고
    • Prescribing, recording and reporting photon beam therapy (supplement to ICRU report 50)
    • ICRU, 62
    • ICRU. Prescribing, recording and reporting photon beam therapy (supplement to ICRU report 50). ICRU report 62 (1999).
    • (1999) ICRU report
  • 3
  • 5
    • 0038497901 scopus 로고    scopus 로고
    • An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments
    • Jiang, S. B., C. Pope, K. M. Al Jarrah, J. H. Kung, T. Bortfeld, and G. T. Chen. An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments. Phys Med Biol 48, 1773-1784 (2003).
    • (2003) Phys Med Biol , vol.48 , pp. 1773-1784
    • Jiang, S.B.1    Pope, C.2    Al Jarrah, K.M.3    Kung, J.H.4    Bortfeld, T.5    Chen, G.T.6
  • 6
    • 0038033835 scopus 로고    scopus 로고
    • The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator
    • Chui, C. S., E. Yorke, and L. Hong. The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator. Med Phys 30, 1736-1746 (2003).
    • (2003) Med Phys , vol.30 , pp. 1736-1746
    • Chui, C.S.1    Yorke, E.2    Hong, L.3
  • 7
    • 17844371743 scopus 로고    scopus 로고
    • Four-dimensional computed tomography: Image formation and clinical protocol
    • Rietzel, E., T. Pan, and G. T. Chen. Four-dimensional computed tomography: image formation and clinical protocol. Med Phys 32, 874-889 (2005).
    • (2005) Med Phys , vol.32 , pp. 874-889
    • Rietzel, E.1    Pan, T.2    Chen, G.T.3
  • 8
    • 0842327786 scopus 로고    scopus 로고
    • Artifacts in computed tomography scanning of moving objects
    • Chen, G. T., J. H. Kung, and K. P. Beaudette. Artifacts in computed tomography scanning of moving objects. Semin Radiat Oncol 14, 19-26 (2004).
    • (2004) Semin Radiat Oncol , vol.14 , pp. 19-26
    • Chen, G.T.1    Kung, J.H.2    Beaudette, K.P.3
  • 9
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • van Herk, M., P. Remeijer, C. Rasch, and J. V. Lebesque. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys 47, 1121-1135 (2000).
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1121-1135
    • van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4
  • 12
    • 0031892627 scopus 로고    scopus 로고
    • The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation
    • Yu, C. X., D. A. Jaffray, and J. W. Wong. The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation. Phys Med Biol 43, 91-104 (1998).
    • (1998) Phys Med Biol , vol.43 , pp. 91-104
    • Yu, C.X.1    Jaffray, D.A.2    Wong, J.W.3
  • 13
    • 0032704370 scopus 로고    scopus 로고
    • A comparison of beam characteristics for gated and nongated clinical x-ray beams
    • Ramsey, C. R., I. L. Cordrey, and A. L. Oliver. A comparison of beam characteristics for gated and nongated clinical x-ray beams. Med Phys 26, 2086-2091 (1999).
    • (1999) Med Phys , vol.26 , pp. 2086-2091
    • Ramsey, C.R.1    Cordrey, I.L.2    Oliver, A.L.3
  • 14
    • 0037036516 scopus 로고    scopus 로고
    • Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation
    • Bortfeld, T., K. Jokivarsi, M. Goitein, J. Kung, and S. B. Jiang. Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. Phys Med Biol 47, 2203-2220 (2002).
    • (2002) Phys Med Biol , vol.47 , pp. 2203-2220
    • Bortfeld, T.1    Jokivarsi, K.2    Goitein, M.3    Kung, J.4    Jiang, S.B.5
  • 16
    • 16344366951 scopus 로고    scopus 로고
    • Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion
    • Rietzel, E., G. T. Chen, N. C. Choi, and C. G. Willet. Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. Int J Radiat Oncol Biol Phys 61, 1535-1550 (2005).
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 1535-1550
    • Rietzel, E.1    Chen, G.T.2    Choi, N.C.3    Willet, C.G.4
  • 17
    • 17844385102 scopus 로고    scopus 로고
    • Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking
    • Keall, P. J., S. Joshi, S. S. Vedam, J. V. Siebers, V. R. Kini, and R. Mohan. Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. Med Phys 32, 942-951 (2005).
    • (2005) Med Phys , vol.32 , pp. 942-951
    • Keall, P.J.1    Joshi, S.2    Vedam, S.S.3    Siebers, J.V.4    Kini, V.R.5    Mohan, R.6
  • 18
    • 33745071905 scopus 로고    scopus 로고
    • A novel four-dimensional radiotherapy method for lung cancer: Imaging, treatment planning and delivery
    • Alasti, H., Y. B. Cho, A. D. Vandermeer, A. Abbas, B. Norrlinger, S. Shubbar, and A. Bezjak. A novel four-dimensional radiotherapy method for lung cancer: imaging, treatment planning and delivery. Phys Med Biol 51, 3251-3267 (2006).
    • (2006) Phys Med Biol , vol.51 , pp. 3251-3267
    • Alasti, H.1    Cho, Y.B.2    Vandermeer, A.D.3    Abbas, A.4    Norrlinger, B.5    Shubbar, S.6    Bezjak, A.7
  • 21
    • 0031803931 scopus 로고    scopus 로고
    • Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging
    • Balter, J. M., K. L. Lam, C. J. McGinn, T. S. Lawrence, and R. K. Ten Haken. Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. Int J Radiat Oncol Biol Phys 41, 939-943 (1998).
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 939-943
    • Balter, J.M.1    Lam, K.L.2    McGinn, C.J.3    Lawrence, T.S.4    Ten Haken, R.K.5
  • 22
    • 0032153006 scopus 로고    scopus 로고
    • Image matching as a diffusion process: An analogy with Maxwell's demons
    • Thirion, J. P. Image matching as a diffusion process: an analogy with Maxwell's demons. Medical image analysis 2, 243-260 (1998).
    • (1998) Medical image analysis , vol.2 , pp. 243-260
    • Thirion, J.P.1
  • 23
    • 31844442905 scopus 로고    scopus 로고
    • Improving retrospective sorting of 4D computed tomography data
    • Rietzel, E. and G. T. Chen. Improving retrospective sorting of 4D computed tomography data. Med Phys 33, 377-379 (2006).
    • (2006) Med Phys , vol.33 , pp. 377-379
    • Rietzel, E.1    Chen, G.T.2
  • 26
    • 4344692365 scopus 로고    scopus 로고
    • Fast free-form deformable registration via calculus of variations
    • Lu, W., M. L. Chen, G. H. Olivera, K. J. Ruchala, and T. R. Mackie. Fast free-form deformable registration via calculus of variations. Phys Med Biol 49, 3067-3087 (2004).
    • (2004) Phys Med Biol , vol.49 , pp. 3067-3087
    • Lu, W.1    Chen, M.L.2    Olivera, G.H.3    Ruchala, K.J.4    Mackie, T.R.5
  • 27
    • 1642280997 scopus 로고    scopus 로고
    • Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images
    • Rohlfing, T., C. R. Maurer, Jr., W. G. O'Dell, and J. Zhong. Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images. Med Phys 31, 427-432 (2004).
    • (2004) Med Phys , vol.31 , pp. 427-432
    • Rohlfing, T.1    Maurer Jr., C.R.2    O'Dell, W.G.3    Zhong, J.4
  • 28
    • 21144441919 scopus 로고    scopus 로고
    • Accuracy of finite element model-based multi-organ deformable image registration
    • Brock, K. K., M. B. Sharpe, L. A. Dawson, S. M. Kim, and D. A. Jaffray. Accuracy of finite element model-based multi-organ deformable image registration. Med Phys 32, 1647-1659 (2005).
    • (2005) Med Phys , vol.32 , pp. 1647-1659
    • Brock, K.K.1    Sharpe, M.B.2    Dawson, L.A.3    Kim, S.M.4    Jaffray, D.A.5
  • 29
    • 33644549665 scopus 로고    scopus 로고
    • Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue
    • Brock, K. K., L. A. Dawson, M. B. Sharpe, D. J. Moseley, and D. A. Jaffray. Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue. Int J Radiat Oncol Biol Phys 64, 1245-1254 (2006).
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 1245-1254
    • Brock, K.K.1    Dawson, L.A.2    Sharpe, M.B.3    Moseley, D.J.4    Jaffray, D.A.5
  • 30
    • 31844438709 scopus 로고    scopus 로고
    • A material sensitivity study on the accuracy of deformable organ registration using linear biomechanical models
    • Chi, Y., J. Liang, and D. Yan. A material sensitivity study on the accuracy of deformable organ registration using linear biomechanical models. Med Phys 33, 421-433 (2006).
    • (2006) Med Phys , vol.33 , pp. 421-433
    • Chi, Y.1    Liang, J.2    Yan, D.3
  • 31
    • 0037701298 scopus 로고    scopus 로고
    • Automated generation of a four-dimensional model of the liver using warping and mutual information
    • Brock, K. M., J. M. Balter, L. A. Dawson, M. L. Kessler, and C. R. Meyer. Automated generation of a four-dimensional model of the liver using warping and mutual information. Med Phys 30, 1128-1133 (2003).
    • (2003) Med Phys , vol.30 , pp. 1128-1133
    • Brock, K.M.1    Balter, J.M.2    Dawson, L.A.3    Kessler, M.L.4    Meyer, C.R.5
  • 32
    • 33750537455 scopus 로고    scopus 로고
    • Deformable registration of 4D computed tomography data
    • Rietzel, E. and G. T. Chen. Deformable registration of 4D computed tomography data. Med Phys 33, 4423-4430 (2006).
    • (2006) Med Phys , vol.33 , pp. 4423-4430
    • Rietzel, E.1    Chen, G.T.2
  • 33
    • 0032008619 scopus 로고    scopus 로고
    • A survey of medical image registration
    • Maintz, J. B. and M. A. Viergever. A survey of medical image registration. Med Image Anal 2, 1-36 (1998).
    • (1998) Med Image Anal , vol.2 , pp. 1-36
    • Maintz, J.B.1    Viergever, M.A.2
  • 34
    • 22544437829 scopus 로고    scopus 로고
    • Semiautomated four-dimensional computed tomography segmentation using deformable models
    • Ragan, D., G. Starkschall, T. McNutt, M. Kaus, T. Guerrero, and C. W. Stevens. Semiautomated four-dimensional computed tomography segmentation using deformable models. Med Phys 32, 2254-2261 (2005).
    • (2005) Med Phys , vol.32 , pp. 2254-2261
    • Ragan, D.1    Starkschall, G.2    McNutt, T.3    Kaus, M.4    Guerrero, T.5    Stevens, C.W.6
  • 37
    • 4043153403 scopus 로고    scopus 로고
    • Performance-based classifier combination in atlas-based image segmentation using expectation-maximization parameter estimation
    • Rohlfing, T., D. B. Russakoff, and C. R. Maurer, Jr. Performance-based classifier combination in atlas-based image segmentation using expectation-maximization parameter estimation. IEEE Trans Med Imaging 23, 983-994 (2004).
    • (2004) IEEE Trans Med Imaging , vol.23 , pp. 983-994
    • Rohlfing, T.1    Russakoff, D.B.2    Maurer Jr., C.R.3
  • 38
    • 0038530967 scopus 로고    scopus 로고
    • The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery
    • Papiez, L. The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery. Math Compta Model 37, 735-745 (2003).
    • (2003) Math Compta Model , vol.37 , pp. 735-745
    • Papiez, L.1
  • 40
    • 33748537791 scopus 로고    scopus 로고
    • IMRT delivery to a moving target by dynamic MLC tracking: Delivery for targets moving in two dimensions in the beam's eye view
    • McQuaid, D. and S. Webb. IMRT delivery to a moving target by dynamic MLC tracking: delivery for targets moving in two dimensions in the beam's eye view. Phys Med Biol 51, 4819-4839 (2006).
    • (2006) Phys Med Biol , vol.51 , pp. 4819-4839
    • McQuaid, D.1    Webb, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.