메뉴 건너뛰기




Volumn 138, Issue 5, 2008, Pages 576-580

Utility of spiral and cine CT scans in pediatric patients suspected of aspirating radiolucent foreign bodies

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ASPIRATION; BRONCHOSCOPE; BRONCHOSCOPY; BRONCHUS; CHILD; CHILD CARE; CINERADIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FALSE POSITIVE RESULT; FEMALE; FOREIGN BODY; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; SENSITIVITY AND SPECIFICITY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; THORAX RADIOGRAPHY;

EID: 42249104526     PISSN: 01945998     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.otohns.2007.12.039     Document Type: Article
Times cited : (67)

References (15)
  • 1
    • 0033937075 scopus 로고    scopus 로고
    • Bronchoscopy for foreign body removal in children. A review and analysis of 210 cases
    • Skoulakis C.E., Doxas P.G., Papadakis C.E., et al. Bronchoscopy for foreign body removal in children. A review and analysis of 210 cases. Int J Pediatr Otorhinolaryngol 53 (2000) 143-148
    • (2000) Int J Pediatr Otorhinolaryngol , vol.53 , pp. 143-148
    • Skoulakis, C.E.1    Doxas, P.G.2    Papadakis, C.E.3
  • 2
    • 0032855432 scopus 로고    scopus 로고
    • Eight years' experience with foreign-body aspiration in children: what is really important for a timely diagnosis?
    • Metrangelo S., Monetti C., Meneghini L., et al. Eight years' experience with foreign-body aspiration in children: what is really important for a timely diagnosis?. J Pediatr Surg 34 (1999) 1229-1231
    • (1999) J Pediatr Surg , vol.34 , pp. 1229-1231
    • Metrangelo, S.1    Monetti, C.2    Meneghini, L.3
  • 3
    • 0024407816 scopus 로고
    • How accurate is chest radiography in the diagnosis of tracheobronchial foreign bodies in children?
    • Svedstrom E., Puhakka H., and Kero P. How accurate is chest radiography in the diagnosis of tracheobronchial foreign bodies in children?. Pediatr Radiol 19 (1989) 520-522
    • (1989) Pediatr Radiol , vol.19 , pp. 520-522
    • Svedstrom, E.1    Puhakka, H.2    Kero, P.3
  • 4
    • 0031740053 scopus 로고    scopus 로고
    • Foreign body aspiration in children: value of radiography and complications of bronchoscopy
    • Zerella J.T., Dimler M., McGill L.C., et al. Foreign body aspiration in children: value of radiography and complications of bronchoscopy. J Pediatr Surg 33 (1998) 1651-1654
    • (1998) J Pediatr Surg , vol.33 , pp. 1651-1654
    • Zerella, J.T.1    Dimler, M.2    McGill, L.C.3
  • 5
    • 0025732562 scopus 로고
    • Detection of a radiolucent bronchial foreign body by computed tomography
    • Gupta A.K., and Berry M. Detection of a radiolucent bronchial foreign body by computed tomography. Pediatr Radiol 21 (1991) 307-308
    • (1991) Pediatr Radiol , vol.21 , pp. 307-308
    • Gupta, A.K.1    Berry, M.2
  • 6
    • 0028855021 scopus 로고
    • Retained bronchial foreign bodies: is there a role for high-resolution computed tomography scan?
    • Malis D.J., and Hayes D.K. Retained bronchial foreign bodies: is there a role for high-resolution computed tomography scan?. Otolaryngol Head Neck Surg 112 (1995) 341-346
    • (1995) Otolaryngol Head Neck Surg , vol.112 , pp. 341-346
    • Malis, D.J.1    Hayes, D.K.2
  • 7
    • 0242721346 scopus 로고    scopus 로고
    • CT virtual bronchoscopy in the evaluation of children with suspected foreign body aspiration
    • Haliloglu M., Ciftci A.O., Oto A., et al. CT virtual bronchoscopy in the evaluation of children with suspected foreign body aspiration. Eur J Radiol 48 (2003) 188-192
    • (2003) Eur J Radiol , vol.48 , pp. 188-192
    • Haliloglu, M.1    Ciftci, A.O.2    Oto, A.3
  • 8
    • 16644365026 scopus 로고    scopus 로고
    • Low-dose MDCT and virtual bronchoscopy in pediatric patients with foreign body aspiration
    • Kosucu P., Ahmetoglu A., Koramaz I., et al. Low-dose MDCT and virtual bronchoscopy in pediatric patients with foreign body aspiration. AJR Am J Roentgenol 183 (2004) 1771-1777
    • (2004) AJR Am J Roentgenol , vol.183 , pp. 1771-1777
    • Kosucu, P.1    Ahmetoglu, A.2    Koramaz, I.3
  • 9
    • 33748483829 scopus 로고    scopus 로고
    • Thin-section axial multidetector computed tomography and multiplanar reformatted imaging of children with suspected foreign-body aspiration: is virtual bronchoscopy overemphasized?
    • Kocaoglu M., Bulakbasi N., Soylu K., et al. Thin-section axial multidetector computed tomography and multiplanar reformatted imaging of children with suspected foreign-body aspiration: is virtual bronchoscopy overemphasized?. Acta Radiol 47 (2006) 746-751
    • (2006) Acta Radiol , vol.47 , pp. 746-751
    • Kocaoglu, M.1    Bulakbasi, N.2    Soylu, K.3
  • 10
    • 33751565990 scopus 로고    scopus 로고
    • Utilization of low-dose multidetector CT and virtual bronchoscopy in children with suspected foreign body aspiration
    • Adaletli I., Kurugoglu S., Ulus S., et al. Utilization of low-dose multidetector CT and virtual bronchoscopy in children with suspected foreign body aspiration. Pediatr Radiol 37 (2007) 33-40
    • (2007) Pediatr Radiol , vol.37 , pp. 33-40
    • Adaletli, I.1    Kurugoglu, S.2    Ulus, S.3
  • 11
    • 0031930163 scopus 로고    scopus 로고
    • Air trapping in children: evaluation with dynamic lung densitometry with spiral CT
    • Johnson J.L., Kramer S.S., and Mahboubi S. Air trapping in children: evaluation with dynamic lung densitometry with spiral CT. Radiology 206 (1998) 95-101
    • (1998) Radiology , vol.206 , pp. 95-101
    • Johnson, J.L.1    Kramer, S.S.2    Mahboubi, S.3
  • 12
    • 33749040214 scopus 로고    scopus 로고
    • Detection of air trapping on inspiratory and expiratory phase images obtained by 0.3-second cine CT in the lungs of free-breathing young children
    • Goo H.W., and Kim H.J. Detection of air trapping on inspiratory and expiratory phase images obtained by 0.3-second cine CT in the lungs of free-breathing young children. AJR Am J Roentgenol 187 (2006) 1019-1023
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 1019-1023
    • Goo, H.W.1    Kim, H.J.2
  • 13
    • 0035199422 scopus 로고    scopus 로고
    • Spiral CT scanning technique in the detection of aspiration of LEGO foreign bodies
    • Applegate K.E., Dardinger J.T., Lieber M.L., et al. Spiral CT scanning technique in the detection of aspiration of LEGO foreign bodies. Pediatr Radiol 31 (2001) 836-840
    • (2001) Pediatr Radiol , vol.31 , pp. 836-840
    • Applegate, K.E.1    Dardinger, J.T.2    Lieber, M.L.3
  • 14
    • 0018923193 scopus 로고
    • Computed tomography and the occult tracheobronchial foreign body
    • Berger P.E., Kuhn J.P., and Kuhns L.R. Computed tomography and the occult tracheobronchial foreign body. Radiology 134 (1980) 133-135
    • (1980) Radiology , vol.134 , pp. 133-135
    • Berger, P.E.1    Kuhn, J.P.2    Kuhns, L.R.3
  • 15
    • 0036584766 scopus 로고    scopus 로고
    • New frontiers in CT imaging of airway disease
    • Grenier P.A., Beigelman-Aubry C., Fetita C., et al. New frontiers in CT imaging of airway disease. Eur Radiol 12 (2002) 1022-1044
    • (2002) Eur Radiol , vol.12 , pp. 1022-1044
    • Grenier, P.A.1    Beigelman-Aubry, C.2    Fetita, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.