-
1
-
-
1942472701
-
Geomagnetic effects on power systems
-
Jul
-
R. J. Ringlee and J. R. Stewart, "Geomagnetic effects on power systems," IEEE Power Eng. Rev., vol. 9, pp. 6-9, Jul. 1989.
-
(1989)
IEEE Power Eng. Rev
, vol.9
, pp. 6-9
-
-
Ringlee, R.J.1
Stewart, J.R.2
-
2
-
-
0024087880
-
Evaluation of the voltage distribution around toroidal HVDC ground electrodes in N-layer soils
-
Oct
-
P. J. Lagace, J. L. Houle, Y. Gervais, and D. Mukhedkar, "Evaluation of the voltage distribution around toroidal HVDC ground electrodes in N-layer soils," IEEE Trans. Power Del., vol. 3, no. 4, pp. 1573-1579, Oct. 1988.
-
(1988)
IEEE Trans. Power Del
, vol.3
, Issue.4
, pp. 1573-1579
-
-
Lagace, P.J.1
Houle, J.L.2
Gervais, Y.3
Mukhedkar, D.4
-
3
-
-
0037817613
-
Soil heating around the ground electrode of an HVDC system by interaction of electrical, thermal, and electroosmotic phenomena
-
Jul
-
J. E. T. Villas and C. M. Portela, "Soil heating around the ground electrode of an HVDC system by interaction of electrical, thermal, and electroosmotic phenomena," IEEE Trans. Power Del., vol. 18, no. 3, pp. 874-881, Jul. 2003.
-
(2003)
IEEE Trans. Power Del
, vol.18
, Issue.3
, pp. 874-881
-
-
Villas, J.E.T.1
Portela, C.M.2
-
4
-
-
0038155356
-
Calculation of electric field and potential distributions into soil and air media for a ground electrode of a HVDC system
-
Jul
-
J. E. T. Villas and C. M. Portela, "Calculation of electric field and potential distributions into soil and air media for a ground electrode of a HVDC system," IEEE Trans. Power Del., vol. 18, no. 3, pp. 867-873, Jul. 2003.
-
(2003)
IEEE Trans. Power Del
, vol.18
, Issue.3
, pp. 867-873
-
-
Villas, J.E.T.1
Portela, C.M.2
-
5
-
-
22044435716
-
3-D nonlinear transient eddy current calculation of online power transformer under DC bias
-
May
-
Y. Yao, C. S. Koh, and G. Ni, "3-D nonlinear transient eddy current calculation of online power transformer under DC bias," IEEE Trans. Magn., vol. 41, no. 5, pp. 1840-1843, May 2005.
-
(2005)
IEEE Trans. Magn
, vol.41
, Issue.5
, pp. 1840-1843
-
-
Yao, Y.1
Koh, C.S.2
Ni, G.3
-
6
-
-
0033184244
-
Transformer design considerations for mitigating geomagnetic induced saturation
-
Sep
-
W. C. Viana, R. J. Micaleff, S. Young, F. P. Dawson, and E. P. Dick, "Transformer design considerations for mitigating geomagnetic induced saturation," IEEE Trans. Magn., vol. 35, no. 5, pt. 2, pp. 3532-3534, Sep. 1999.
-
(1999)
IEEE Trans. Magn
, vol.35
, Issue.5 PART. 2
, pp. 3532-3534
-
-
Viana, W.C.1
Micaleff, R.J.2
Young, S.3
Dawson, F.P.4
Dick, E.P.5
-
7
-
-
0033114893
-
Modeling and simulation, and their validation of three-phase transformers with three legs under DC bias
-
Apr
-
E. F. Fuchs, Y. You, and D. J. Roesler, "Modeling and simulation, and their validation of three-phase transformers with three legs under DC bias," IEEE Trans. Power Del., vol. 14, no. 2, pp. 443-449, Apr. 1999.
-
(1999)
IEEE Trans. Power Del
, vol.14
, Issue.2
, pp. 443-449
-
-
Fuchs, E.F.1
You, Y.2
Roesler, D.J.3
-
8
-
-
27644497582
-
-
J. Zhao and B. Zhang, Effect of transmission line's ground wire on the DC ground current flowing through the neutral point of the transformer, (in Chinese) Power Syst. Technol., 29, pp. 60-64, Oct. 2005.
-
J. Zhao and B. Zhang, "Effect of transmission line's ground wire on the DC ground current flowing through the neutral point of the transformer," (in Chinese) Power Syst. Technol., vol. 29, pp. 60-64, Oct. 2005.
-
-
-
-
9
-
-
0038155356
-
Calculation of electric field and potential distributions into soil and air media for a ground electrode of a HVDC system
-
Jul
-
J. E. T. Villas and C. M. Portela, "Calculation of electric field and potential distributions into soil and air media for a ground electrode of a HVDC system," IEEE Trans. Power Del., vol. 18, no. 3, pp. 867-873, Jul. 2003.
-
(2003)
IEEE Trans. Power Del
, vol.18
, Issue.3
, pp. 867-873
-
-
Villas, J.E.T.1
Portela, C.M.2
-
10
-
-
42249100989
-
EPRI EL-2020, project 1467-1
-
San Francisco, CA
-
"EPRI EL-2020, project 1467-1," in HVDC Ground Electrode Design, San Francisco, CA, 1981, pp. 4.1-4.6.
-
(1981)
HVDC Ground Electrode Design
-
-
-
12
-
-
0026135780
-
Calculation of earth resistivity for a deep-driven rod in a multi-layer earth structure
-
Apr
-
T. Takahashi and T. Kawase, "Calculation of earth resistivity for a deep-driven rod in a multi-layer earth structure," IEEE Trans. Power Del., vol. 6, no. 2, pp. 608-614, Apr. 1991.
-
(1991)
IEEE Trans. Power Del
, vol.6
, Issue.2
, pp. 608-614
-
-
Takahashi, T.1
Kawase, T.2
-
13
-
-
0000402053
-
Complex images of a ground electrode in layered soils
-
Jan
-
Y. L. Chow, J. J. Yang, and K. D. Srivastava, "Complex images of a ground electrode in layered soils," J. Appl. Phys., vol. 71, pp. 569-574, Jan. 1992.
-
(1992)
J. Appl. Phys
, vol.71
, pp. 569-574
-
-
Chow, Y.L.1
Yang, J.J.2
Srivastava, K.D.3
-
14
-
-
17744394916
-
Parameter estimation of horizontal multilayer earth by complex image method
-
Apr
-
B. Zhang, X. Cui, L. Li, and J. He, "Parameter estimation of horizontal multilayer earth by complex image method," IEEE Trans. Power Del. vol. 20, no. 2, pt. 2, pp. 1394-1401, Apr. 2005.
-
(2005)
IEEE Trans. Power Del
, vol.20
, Issue.2 PART. 2
, pp. 1394-1401
-
-
Zhang, B.1
Cui, X.2
Li, L.3
He, J.4
|