메뉴 건너뛰기




Volumn 61, Issue 4, 2008, Pages 419-425

What is a significant difference between sequential laboratory results?

Author keywords

[No Author keywords available]

Indexed keywords

CHEMICAL ANALYSIS; CLINICAL PRACTICE; HUMAN; LABORATORY TEST; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; REVIEW; SEQUENTIAL ANALYSIS;

EID: 42049115869     PISSN: 00219746     EISSN: None     Source Type: Journal    
DOI: 10.1136/jcp.2007.047175     Document Type: Review
Times cited : (29)

References (45)
  • 1
    • 30844441744 scopus 로고    scopus 로고
    • Renal Association, UK Guidelines for Identification, Management and Referral, accessed 25 June 2007
    • Renal Association. Chronic kidney disease in adults: UK Guidelines for Identification, Management and Referral. http://www.renal.org/CKDguide/ full/UKCKDfull.pdf (accessed 25 June 2007).
    • Chronic kidney disease in adults
  • 2
    • 42049118032 scopus 로고    scopus 로고
    • Royal College of Physicians of Edinburgh, Royal College of Physicians of Edinburgh
    • Royal College of Physicians of Edinburgh. UK consensus conference on early chronic kidney disease. Royal College of Physicians of Edinburgh, 2007.
    • (2007) UK consensus conference on early chronic kidney disease
  • 4
    • 0016321204 scopus 로고
    • Effects of intra and interindividual variation on the appropriate use of normal intervals
    • Harris EK. Effects of intra and interindividual variation on the appropriate use of normal intervals. Clin Chem 1974;20:1535-42.
    • (1974) Clin Chem , vol.20 , pp. 1535-1542
    • Harris, E.K.1
  • 5
    • 4344570957 scopus 로고    scopus 로고
    • Inherent biological variation and reference values
    • Fraser CG. Inherent biological variation and reference values. Clin Chem Lab Med 2004;42:758-64.
    • (2004) Clin Chem Lab Med , vol.42 , pp. 758-764
    • Fraser, C.G.1
  • 6
    • 0023943816 scopus 로고
    • Proposed goals for analytical precision and accuracy in single point diagnostic testing
    • Harris EK. Proposed goals for analytical precision and accuracy in single point diagnostic testing. Arch Pathol Lab Med 1988;112:416-20.
    • (1988) Arch Pathol Lab Med , vol.112 , pp. 416-420
    • Harris, E.K.1
  • 7
    • 0027942080 scopus 로고
    • Allowable imprecision for laboratory tests based on clinical and analytical test outcome criteria
    • Westgard JO, Seehafer JJ, Barry PL. Allowable imprecision for laboratory tests based on clinical and analytical test outcome criteria. Clin Chem 1994;40:1909-14.
    • (1994) Clin Chem , vol.40 , pp. 1909-1914
    • Westgard, J.O.1    Seehafer, J.J.2    Barry, P.L.3
  • 8
    • 0027457005 scopus 로고
    • Quality goals in external quality assessment are best based on biology
    • Fraser CG, Hyltoft Petersen P. Quality goals in external quality assessment are best based on biology. Scand J Clin Lab Invest 1993;212(Suppl 53):8-9.
    • (1993) Scand J Clin Lab Invest , vol.212 , Issue.SUPPL. 53 , pp. 8-9
    • Fraser, C.G.1    Hyltoft Petersen, P.2
  • 9
    • 42049116517 scopus 로고    scopus 로고
    • Various preanalytical variables and their effects on the quality of laboratory results
    • Cvitkovic L, Mesic R. Various preanalytical variables and their effects on the quality of laboratory results. Diabetologia Croatica 1999:28-2.
    • (1999) Diabetologia Croatica , pp. 28-32
    • Cvitkovic, L.1    Mesic, R.2
  • 10
    • 1642586766 scopus 로고    scopus 로고
    • Management problems: Pitfalls in the interpretation of common biochemical tests
    • Ayling RM. Management problems: pitfalls in the interpretation of common biochemical tests. Postgrad Med J 2000;76:129-32.
    • (2000) Postgrad Med J , vol.76 , pp. 129-132
    • Ayling, R.M.1
  • 11
    • 0001918547 scopus 로고
    • Specimen collection and processing: Sources of biological variation
    • Teitz NW, ed, Philadelphia: WB Saunders
    • Young DS, Bermes EW. Specimen collection and processing: sources of biological variation. In: Teitz NW, ed. Textbook of clinical chemistry. Philadelphia: WB Saunders, 1987:58-101.
    • (1987) Textbook of clinical chemistry , pp. 58-101
    • Young, D.S.1    Bermes, E.W.2
  • 12
    • 0024591868 scopus 로고
    • Diurnal variations in serum biochemical and haematological measurements
    • Pocock SJ, Ashby D, Shaper AG, et al. Diurnal variations in serum biochemical and haematological measurements. J Clin Pathol 1989;42:172-9.
    • (1989) J Clin Pathol , vol.42 , pp. 172-179
    • Pocock, S.J.1    Ashby, D.2    Shaper, A.G.3
  • 13
    • 0024515570 scopus 로고
    • Circadian and seasonal variations of electrolytes in aging humans
    • Touituo Y, Touituo C, Bogdan A, et al. Circadian and seasonal variations of electrolytes in aging humans. Clin Chem Acta 1989;180:245-54.
    • (1989) Clin Chem Acta , vol.180 , pp. 245-254
    • Touituo, Y.1    Touituo, C.2    Bogdan, A.3
  • 14
    • 0009214388 scopus 로고
    • Influence of food intake on biological parameters
    • Siest G, ed, Basle: Karger
    • Steinmetz J, Panek E, Sourieau F, et al. Influence of food intake on biological parameters. In: Siest G, ed. Reference values in human chemistry. Basle: Karger, 1973:195-200.
    • (1973) Reference values in human chemistry , pp. 195-200
    • Steinmetz, J.1    Panek, E.2    Sourieau, F.3
  • 15
    • 0020678727 scopus 로고
    • The influence of a cooked meal on creatinine plasma concentration and creatinine clearance
    • Mayersohn M, Conrad KA, Achari R. The influence of a cooked meal on creatinine plasma concentration and creatinine clearance. Br J Pharmacol 1983;15:227-30.
    • (1983) Br J Pharmacol , vol.15 , pp. 227-230
    • Mayersohn, M.1    Conrad, K.A.2    Achari, R.3
  • 16
    • 0036727202 scopus 로고    scopus 로고
    • Biochemical measures in a population-based study: Effect of fasting duration and time of day
    • Emberson JR, Whincup PH, Walker M, et al. Biochemical measures in a population-based study: effect of fasting duration and time of day. Ann Clin Biochem 2002;39:493-501.
    • (2002) Ann Clin Biochem , vol.39 , pp. 493-501
    • Emberson, J.R.1    Whincup, P.H.2    Walker, M.3
  • 17
    • 0019158778 scopus 로고
    • Effects of posture on concentrations of blood constituents in healthy adults: Practical application of blood specimen collection procedures recommended by the Scandinavian Committee on Reference Values
    • Felding P, Tryding N, Hyltoft Petersen P. Effects of posture on concentrations of blood constituents in healthy adults: practical application of blood specimen collection procedures recommended by the Scandinavian Committee on Reference Values. Scand J Clin Lab Invest 1980;40:615-21.
    • (1980) Scand J Clin Lab Invest , vol.40 , pp. 615-621
    • Felding, P.1    Tryding, N.2    Hyltoft Petersen, P.3
  • 18
    • 0016336085 scopus 로고
    • Factors contributing to intraindividual variation of serum constituents. 4. Effects of posture and tourniquet application on variation of serum constituents in health subjects
    • Statland BE, Bokelund H, Winkel P. Factors contributing to intraindividual variation of serum constituents. 4. Effects of posture and tourniquet application on variation of serum constituents in health subjects. Clin Chem 1974;20:1513-9.
    • (1974) Clin Chem , vol.20 , pp. 1513-1519
    • Statland, B.E.1    Bokelund, H.2    Winkel, P.3
  • 19
    • 0034039258 scopus 로고    scopus 로고
    • Seasonal and biological variation of blood concentrations of total cholesterol, dehydroepiandrosterone sulphate, haemoglobin A1c, IgA, prolactin, and free testosterone in healthy women
    • Garde AH, Hansen AM, Skovgaard LT, et al. Seasonal and biological variation of blood concentrations of total cholesterol, dehydroepiandrosterone sulphate, haemoglobin A1c, IgA, prolactin, and free testosterone in healthy women. Clin Chem 2000;46:551-9.
    • (2000) Clin Chem , vol.46 , pp. 551-559
    • Garde, A.H.1    Hansen, A.M.2    Skovgaard, L.T.3
  • 20
    • 11144355236 scopus 로고    scopus 로고
    • Seasonal variation in serum cholesterol levels. Treatment implications and possible mechanisms
    • Ockene IS, Chiriboga DE, Stanek EJ, et al. Seasonal variation in serum cholesterol levels. Treatment implications and possible mechanisms. Arch Intern Med 2004;164:863-70.
    • (2004) Arch Intern Med , vol.164 , pp. 863-870
    • Ockene, I.S.1    Chiriboga, D.E.2    Stanek, E.J.3
  • 21
    • 0036707887 scopus 로고    scopus 로고
    • Seasonal variations in clinical and laboratory variables among chronic haemodialysis patients
    • Cheung AK, Yan G, Greene T, et al. Seasonal variations in clinical and laboratory variables among chronic haemodialysis patients. J Am Soc Nephrol 2002;13:2345-52.
    • (2002) J Am Soc Nephrol , vol.13 , pp. 2345-2352
    • Cheung, A.K.1    Yan, G.2    Greene, T.3
  • 22
    • 0026059306 scopus 로고
    • Biochemical consequence of exercise
    • Stansbie D, Begley JP. Biochemical consequence of exercise. J IFCC 1991;3:87-91.
    • (1991) J IFCC , vol.3 , pp. 87-91
    • Stansbie, D.1    Begley, J.P.2
  • 24
    • 0023633099 scopus 로고
    • Intra-individual variation of some analytes in serum of patients with chronic renal failure
    • Holzel WGE. Intra-individual variation of some analytes in serum of patients with chronic renal failure. Clin Chem 1987;33:670-3.
    • (1987) Clin Chem , vol.33 , pp. 670-673
    • Holzel, W.G.E.1
  • 25
    • 0020676495 scopus 로고
    • Short term biological variation of plasma analytes in renal disease
    • Fraser CG, Williams P. Short term biological variation of plasma analytes in renal disease. Clin Chem 1983;29:508-10.
    • (1983) Clin Chem , vol.29 , pp. 508-510
    • Fraser, C.G.1    Williams, P.2
  • 26
    • 0032813935 scopus 로고    scopus 로고
    • Transport and temperature effects on measurement of serum and plasma potassium
    • Seamark D, Backhouse S, Barber P, et al. Transport and temperature effects on measurement of serum and plasma potassium. J R Soc Med 1999;92:339-41.
    • (1999) J R Soc Med , vol.92 , pp. 339-341
    • Seamark, D.1    Backhouse, S.2    Barber, P.3
  • 27
    • 0029899397 scopus 로고    scopus 로고
    • High ambient temperature: A spurious cause of hypokalaemia
    • Masters PW, Lawson N, Marenah CB, et al. High ambient temperature: a spurious cause of hypokalaemia. BMJ 1996;312:1652- 53.
    • (1996) BMJ , vol.312 , pp. 1652-1653
    • Masters, P.W.1    Lawson, N.2    Marenah, C.B.3
  • 28
    • 0035315904 scopus 로고    scopus 로고
    • Screening and treating adults for lipid disorders
    • Pignone MP, Philips CJ, et al. Screening and treating adults for lipid disorders. Am J Prev Med 2001;20(3S):77-89.
    • (2001) Am J Prev Med , vol.20 , Issue.3 S , pp. 77-89
    • Pignone, M.P.1    Philips, C.J.2
  • 31
    • 12944289664 scopus 로고    scopus 로고
    • Estimate of biological variation of laboratory analytes based on third National Health and Nutrition Examination Survey
    • Lacher DA, Hughes JP, Carroll MD. Estimate of biological variation of laboratory analytes based on third National Health and Nutrition Examination Survey. Clin Chem 2005;51:450-2.
    • (2005) Clin Chem , vol.51 , pp. 450-452
    • Lacher, D.A.1    Hughes, J.P.2    Carroll, M.D.3
  • 35
    • 0022378262 scopus 로고
    • Intra-individual variation: Significant changes in parameters of lipid and carbohydrate metabolism in the individual and intra-individual variation in different test populations
    • Godsland I. Intra-individual variation: significant changes in parameters of lipid and carbohydrate metabolism in the individual and intra-individual variation in different test populations. Ann Clin Biochem 1985;22:618-24.
    • (1985) Ann Clin Biochem , vol.22 , pp. 618-624
    • Godsland, I.1
  • 36
    • 0031912493 scopus 로고    scopus 로고
    • Biological variation of glycated haemoglobin: Implications for diabetic screening and treatment
    • Kilpatrick ES, Maylor PW, Keevil BG, et al. Biological variation of glycated haemoglobin: implications for diabetic screening and treatment. Clin Chem 1998;21:261-4.
    • (1998) Clin Chem , vol.21 , pp. 261-264
    • Kilpatrick, E.S.1    Maylor, P.W.2    Keevil, B.G.3
  • 37
    • 0027963224 scopus 로고
    • Intensive diabetes management requires very precise testing of glycohemoglobin
    • Kolatkar NS, Cembrowski GS, Callahan PL, et al. Intensive diabetes management requires very precise testing of glycohemoglobin. Clin Chem 1994;40:1608-10.
    • (1994) Clin Chem , vol.40 , pp. 1608-1610
    • Kolatkar, N.S.1    Cembrowski, G.S.2    Callahan, P.L.3
  • 38
    • 0002066015 scopus 로고
    • Prerequisites for the maintenance of a certain state of health by biochemical monitoring
    • Harris EK, Yasala T. eds, North Holland: Elsevier
    • Hyltoft Petersen P, Lytken Larsen M, Horder M. Prerequisites for the maintenance of a certain state of health by biochemical monitoring. In: Harris EK, Yasala T. eds. Maintaining a healthy state within the individual. North Holland: Elsevier, 1987:147-51.
    • (1987) Maintaining a healthy state within the individual , pp. 147-151
    • Hyltoft Petersen, P.1    Lytken Larsen, M.2    Horder, M.3
  • 39
    • 0034825945 scopus 로고    scopus 로고
    • Components of total measurement for haemoglobin A1c
    • Phillipou G, Phillips P. Components of total measurement for haemoglobin A1c. Clin Chem 2001;47:1851-3.
    • (2001) Clin Chem , vol.47 , pp. 1851-1853
    • Phillipou, G.1    Phillips, P.2
  • 40
    • 0024835246 scopus 로고
    • Epidemiological features of glycated haemoglobin A1c-distribution in a health population. The Telecom Study
    • Simon D, Senan C, Garnie P, et al. Epidemiological features of glycated haemoglobin A1c-distribution in a health population. The Telecom Study. Diabetologia 1989;32:864-9.
    • (1989) Diabetologia , vol.32 , pp. 864-869
    • Simon, D.1    Senan, C.2    Garnie, P.3
  • 41
    • 0036089730 scopus 로고    scopus 로고
    • Biological variation of glycohemoglobin
    • Rohlfing C, Wiedmeyer H-M, Little R, et al. Biological variation of glycohemoglobin. Clin Chem 2002;48:1116-8.
    • (2002) Clin Chem , vol.48 , pp. 1116-1118
    • Rohlfing, C.1    Wiedmeyer, H.-M.2    Little, R.3
  • 42
    • 42049093981 scopus 로고    scopus 로고
    • Renal Association, accessed 25 June 2007
    • Renal Association. UK CKD eGFR calculator. http://www.renal.org/ eGFRcalc/GFR.pl (accessed 25 June 2007).
    • UK CKD eGFR calculator
  • 43
    • 33747040574 scopus 로고    scopus 로고
    • Best practice in primary care pathology. Review 3
    • Smellie WSA, Forth JO, Bareford D, et al. Best practice in primary care pathology. Review 3. J Clin Pathol 2006;59:781-9.
    • (2006) J Clin Pathol , vol.59 , pp. 781-789
    • Smellie, W.S.A.1    Forth, J.O.2    Bareford, D.3
  • 44
    • 84970857770 scopus 로고
    • Regression towards the mean
    • Bland JM, Altman DG. Regression towards the mean. BMJ 1994;308:1499.
    • (1994) BMJ , vol.308 , pp. 1499
    • Bland, J.M.1    Altman, D.G.2
  • 45
    • 0024577077 scopus 로고
    • How sensitive are immunometric assays for thyrotropin?
    • McConway MG, Chapman RS, Beastall GH, et al. How sensitive are immunometric assays for thyrotropin? Clin Chem 1989;35:289-91.
    • (1989) Clin Chem , vol.35 , pp. 289-291
    • McConway, M.G.1    Chapman, R.S.2    Beastall, G.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.