-
1
-
-
34247866264
-
Evaluation of four point-of-care meters for rapid determination of blood lactate concentrations in dogs
-
Acierno M., and Mitchell M. Evaluation of four point-of-care meters for rapid determination of blood lactate concentrations in dogs. Journal of the American Veterinary Medical Association 230 (2007) 1315-1318
-
(2007)
Journal of the American Veterinary Medical Association
, vol.230
, pp. 1315-1318
-
-
Acierno, M.1
Mitchell, M.2
-
2
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
4
-
-
0035153310
-
Point-of-care (poc) testing of lactate in the intensive care patient. Accuracy, reliability, and costs of different measurement systems
-
Boldt J., Kumle B., Suttner S., and Haisch G. Point-of-care (poc) testing of lactate in the intensive care patient. Accuracy, reliability, and costs of different measurement systems. Acta Anaesthesiologia Scandavia 45 (2001) 194-199
-
(2001)
Acta Anaesthesiologia Scandavia
, vol.45
, pp. 194-199
-
-
Boldt, J.1
Kumle, B.2
Suttner, S.3
Haisch, G.4
-
5
-
-
0033160591
-
Plasma lactate concentration as a predictor of gastric necrosis and survival among dogs with gastric dilatation-volvulus: 102 cases (1995-1998)
-
de Papp E., Drobatz K.J., and Hughes D. Plasma lactate concentration as a predictor of gastric necrosis and survival among dogs with gastric dilatation-volvulus: 102 cases (1995-1998). Journal of the American Veterinary Medical Association 215 (1999) 49-52
-
(1999)
Journal of the American Veterinary Medical Association
, vol.215
, pp. 49-52
-
-
de Papp, E.1
Drobatz, K.J.2
Hughes, D.3
-
7
-
-
0035036967
-
The value of blood lactate measurements in icu: an evaluation of the role in the management of patients on haemofiltration
-
Holloway P., Benham S., and St John A. The value of blood lactate measurements in icu: an evaluation of the role in the management of patients on haemofiltration. Clinica Chimica Acta 307 (2001) 9-13
-
(2001)
Clinica Chimica Acta
, vol.307
, pp. 9-13
-
-
Holloway, P.1
Benham, S.2
St John, A.3
-
8
-
-
0002544448
-
Lactate measurement: diagnostic, therapeutic, and prognostic implications
-
Bonagura J. (Ed), WB Saunders, Philadelphia
-
Hughes D. Lactate measurement: diagnostic, therapeutic, and prognostic implications. In: Bonagura J. (Ed). Kirk's Current Veterinary Therapy xiii (1999), WB Saunders, Philadelphia 112-116
-
(1999)
Kirk's Current Veterinary Therapy xiii
, pp. 112-116
-
-
Hughes, D.1
-
9
-
-
0037408227
-
Serum lactate and base deficit as predictors of mortality and morbidity
-
Husain F.A., Martin M.J., Mullenix P.S., Steele S.R., and Elliott D.C. Serum lactate and base deficit as predictors of mortality and morbidity. American Journal of Surgery 185 (2003) 485-491
-
(2003)
American Journal of Surgery
, vol.185
, pp. 485-491
-
-
Husain, F.A.1
Martin, M.J.2
Mullenix, P.S.3
Steele, S.R.4
Elliott, D.C.5
-
10
-
-
0033533116
-
Lactate is an unreliable indicator of tissue hypoxia in injury or sepsis
-
James J.H., Luchette F.A., McCarter F.D., and Fischer J.E. Lactate is an unreliable indicator of tissue hypoxia in injury or sepsis. Lancet 354 (1999) 505-508
-
(1999)
Lancet
, vol.354
, pp. 505-508
-
-
James, J.H.1
Luchette, F.A.2
McCarter, F.D.3
Fischer, J.E.4
-
11
-
-
0034761984
-
Serial measurement of arterial lactate concentrations as a prognostic indicator in relation to the incidence of disseminated intravascular coagulation in patients with systemic inflammatory response syndrome
-
Kobayashi S., Gando S., Morimoto Y., Nanzaki S., and Kemmotsu O. Serial measurement of arterial lactate concentrations as a prognostic indicator in relation to the incidence of disseminated intravascular coagulation in patients with systemic inflammatory response syndrome. Surgery Today 31 (2001) 853-859
-
(2001)
Surgery Today
, vol.31
, pp. 853-859
-
-
Kobayashi, S.1
Gando, S.2
Morimoto, Y.3
Nanzaki, S.4
Kemmotsu, O.5
-
15
-
-
0030939027
-
Dangerous curves. A perspective on exercise, lactate, and the anaerobic threshold
-
Myers J., and Ashley E. Dangerous curves. A perspective on exercise, lactate, and the anaerobic threshold. Chest 111 (1997) 787-795
-
(1997)
Chest
, vol.111
, pp. 787-795
-
-
Myers, J.1
Ashley, E.2
-
17
-
-
4243091690
-
Prognostic value of blood lactate, blood glucose, and hematocrit in canine babesiosis
-
Nel M., Lobetti R.G., Keller N., and Thompson P.N. Prognostic value of blood lactate, blood glucose, and hematocrit in canine babesiosis. Journal of Veterinary Internal Medicine 18 (2004) 471-476
-
(2004)
Journal of Veterinary Internal Medicine
, vol.18
, pp. 471-476
-
-
Nel, M.1
Lobetti, R.G.2
Keller, N.3
Thompson, P.N.4
-
18
-
-
3943052086
-
Early lactate clearance is associated with improved outcome in severe sepsis and septic shock
-
Nguyen H.B., Rivers E.P., Knoblich B.P., Jacobsen G., Muzzin A., Ressler J.A., and Tomlanovich M.C. Early lactate clearance is associated with improved outcome in severe sepsis and septic shock. Critical Care Medicine 32 (2004) 1637-1642
-
(2004)
Critical Care Medicine
, vol.32
, pp. 1637-1642
-
-
Nguyen, H.B.1
Rivers, E.P.2
Knoblich, B.P.3
Jacobsen, G.4
Muzzin, A.5
Ressler, J.A.6
Tomlanovich, M.C.7
-
19
-
-
0004551137
-
Comparing several methods of measuring the same quality
-
Seed P. Comparing several methods of measuring the same quality. Stata Technical Bulletin 10 (2000) 2-9
-
(2000)
Stata Technical Bulletin
, vol.10
, pp. 2-9
-
-
Seed, P.1
-
20
-
-
0024453396
-
Test-strip method for measuring lactate in whole blood
-
Shimojo N., Naka K., Nakajima C., Yoshikawa C., Okuda K., and Okada K. Test-strip method for measuring lactate in whole blood. Clinical Chemistry 35 (1989) 1992-1994
-
(1989)
Clinical Chemistry
, vol.35
, pp. 1992-1994
-
-
Shimojo, N.1
Naka, K.2
Nakajima, C.3
Yoshikawa, C.4
Okuda, K.5
Okada, K.6
-
21
-
-
0027503862
-
Electrochemical assay system with single-use electrode strip for measuring lactate in whole blood
-
Shimojo N., Naka K., Uenoyama H., Hamamoto K., Yoshioka K., and Okuda K. Electrochemical assay system with single-use electrode strip for measuring lactate in whole blood. Clinical Chemistry 39 (1993) 2312-2314
-
(1993)
Clinical Chemistry
, vol.39
, pp. 2312-2314
-
-
Shimojo, N.1
Naka, K.2
Uenoyama, H.3
Hamamoto, K.4
Yoshioka, K.5
Okuda, K.6
-
22
-
-
0031688136
-
Validation of a hand-held lactate device in determination of blood lactate in critically injured patients
-
Slomovitz B.M., Lavery R.F., Tortella B.J., Siegel J.H., Bachl B.L., and Ciccone A. Validation of a hand-held lactate device in determination of blood lactate in critically injured patients. Critical Care Medicine 26 (1998) 1523-1528
-
(1998)
Critical Care Medicine
, vol.26
, pp. 1523-1528
-
-
Slomovitz, B.M.1
Lavery, R.F.2
Tortella, B.J.3
Siegel, J.H.4
Bachl, B.L.5
Ciccone, A.6
-
23
-
-
0014794257
-
Experimental and clinical studies on lactate and pyruvate as indicators of the severity of acute circulatory failure (shock)
-
Weil M.H., and Afifi A.A. Experimental and clinical studies on lactate and pyruvate as indicators of the severity of acute circulatory failure (shock). Circulation 41 (1970) 989-1001
-
(1970)
Circulation
, vol.41
, pp. 989-1001
-
-
Weil, M.H.1
Afifi, A.A.2
|