메뉴 건너뛰기




Volumn 40, Issue 1, 2008, Pages 65-67

Use of a new implantable adjustable pulmonary artery banding device: A report of two patients

Author keywords

Banding; Mechanical device; Palliation; Pulmonary artery

Indexed keywords

ARTERIAL PRESSURE; ARTERY BLOOD FLOW; ARTICLE; CASE REPORT; DENMARK; HEART LEFT RIGHT SHUNT; HEART VENTRICLE SEPTUM DEFECT; HUMAN; IMPLANTATION; LUNG ARTERY BANDING; MALE; NEWBORN; PULMONARY ARTERY BANDING DEVICE; RISK REDUCTION; SURGICAL EQUIPMENT; SURGICAL RISK;

EID: 41949086930     PISSN: 00221058     EISSN: 29698960     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (5)
  • 1
    • 0001132256 scopus 로고
    • The treatment of certain congenital malformations of the heart by the creation of pulmonic stenosis to reduce pulmonary hypertension and excessive pulmonary blood flow
    • Muller WH, Dammann JF Jr. The treatment of certain congenital malformations of the heart by the creation of pulmonic stenosis to reduce pulmonary hypertension and excessive pulmonary blood flow. Surg Gynecol Obstet. 1952;95:213-9.
    • (1952) Surg Gynecol Obstet , vol.95 , pp. 213-219
    • Muller, W.H.1    Dammann Jr., J.F.2
  • 2
    • 0018879151 scopus 로고
    • The changing role of palliative procedures in the treatment of infants with congenital heart disease
    • Turley K, Tucker WY, Ebert PA. The changing role of palliative procedures in the treatment of infants with congenital heart disease. J Thorac Cardiovasc Surg. 1980;79:194-210.
    • (1980) J Thorac Cardiovasc Surg , vol.79 , pp. 194-210
    • Turley, K.1    Tucker, W.Y.2    Ebert, P.A.3
  • 3
    • 0015009926 scopus 로고
    • An adjustable pulmonary artery band
    • Fishman NH, Roe BB. An adjustable pulmonary artery band. Arch Surg. 1971;102:143.
    • (1971) Arch Surg , vol.102 , pp. 143
    • Fishman, N.H.1    Roe, B.B.2
  • 4
    • 85160884993 scopus 로고    scopus 로고
    • Bonnet D, Corno AF, Sidi D, et al. Early clinical results of the telemetric adjustable pulmonary artery banding FloWatch-PAB. Circulation. 2004;110:II-158-63.
    • Bonnet D, Corno AF, Sidi D, et al. Early clinical results of the telemetric adjustable pulmonary artery banding FloWatch-PAB. Circulation. 2004;110:II-158-63.
  • 5
    • 24644503652 scopus 로고    scopus 로고
    • Pseudoaneurysm of the pulmonary trunk after the placement of an adjustable pulmonary artery banding device (FloWatch-PAB) in a patient with muscular ventricular septal defect
    • Michael-Behnke I, Akintuerk H, Valeske K, Thule J, Mueller M, Schranz D. Pseudoaneurysm of the pulmonary trunk after the placement of an adjustable pulmonary artery banding device (FloWatch-PAB) in a patient with muscular ventricular septal defect. J Thorac Cardiovasc Surg. 2005;130:894-5.
    • (2005) J Thorac Cardiovasc Surg , vol.130 , pp. 894-895
    • Michael-Behnke, I.1    Akintuerk, H.2    Valeske, K.3    Thule, J.4    Mueller, M.5    Schranz, D.6