메뉴 건너뛰기




Volumn 15, Issue 7, 2008, Pages 981-988

Failure analysis of uncemented total hip stem due to microstructure and neck stress riser

Author keywords

Corrosion fatigue; Failure analysis; THA

Indexed keywords

COMPUTER SIMULATION; CORROSION; FAILURE ANALYSIS; FRACTURE; MICROSTRUCTURE; STRESSES;

EID: 41849097799     PISSN: 13506307     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.engfailanal.2007.10.012     Document Type: Article
Times cited : (27)

References (16)
  • 1
    • 0036714484 scopus 로고    scopus 로고
    • Charnley low-friction arthroplasty-a worldwide retrospective review at 15 to 20 years
    • Older J. Charnley low-friction arthroplasty-a worldwide retrospective review at 15 to 20 years. Journal of Arthroplasty 17 6 (2002) 675-680
    • (2002) Journal of Arthroplasty , vol.17 , Issue.6 , pp. 675-680
    • Older, J.1
  • 2
    • 0036258759 scopus 로고    scopus 로고
    • Charnley low-frictional torque arthroplasty in patients under the age of 51 years. Follow-up to 33 years
    • Wroblewski B.M., Siney P.D., and Fleming P.A. Charnley low-frictional torque arthroplasty in patients under the age of 51 years. Follow-up to 33 years. J Bone Joint Surg Br 84 4 (2002) 540-543
    • (2002) J Bone Joint Surg Br , vol.84 , Issue.4 , pp. 540-543
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3
  • 4
    • 0025956699 scopus 로고
    • Fatigue failure of noncemented porous-coated implants a retrieval study
    • Cook S.D., and Thomas K.A. Fatigue failure of noncemented porous-coated implants a retrieval study. J Bone Joint Surg Br 73-B (1991) 20-24
    • (1991) J Bone Joint Surg Br , vol.73 -B , pp. 20-24
    • Cook, S.D.1    Thomas, K.A.2
  • 5
    • 0019811096 scopus 로고
    • Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases
    • Chao E.Y., and Coventry M.B. Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases. J Bone Joint Surg Am 63 (1981) 1078-1094
    • (1981) J Bone Joint Surg Am , vol.63 , pp. 1078-1094
    • Chao, E.Y.1    Coventry, M.B.2
  • 6
    • 0035116654 scopus 로고    scopus 로고
    • Early fatigue failures of cemented, forged, cobalt-chromium femoral stems at the neck-shoulder junction
    • Lee E.W., and Kim H.T. Early fatigue failures of cemented, forged, cobalt-chromium femoral stems at the neck-shoulder junction. J Arthroplast 16 2 (2001)
    • (2001) J Arthroplast , vol.16 , Issue.2
    • Lee, E.W.1    Kim, H.T.2
  • 7
    • 0029955673 scopus 로고    scopus 로고
    • Outcome of revision for mechanical stem failure using the cemented Charnley's stem A study of 399 cases
    • Raut V.V., Siney P.D., and Wroblewski B.M. Outcome of revision for mechanical stem failure using the cemented Charnley's stem A study of 399 cases. J Arthroplast 11 4 (1996)
    • (1996) J Arthroplast , vol.11 , Issue.4
    • Raut, V.V.1    Siney, P.D.2    Wroblewski, B.M.3
  • 8
    • 0033857197 scopus 로고    scopus 로고
    • A stem design change to reduce peak cement strains at the tip of cemented total hip arthroplasty
    • Estok D.M., and Harris W.H. A stem design change to reduce peak cement strains at the tip of cemented total hip arthroplasty. J Arthroplast 15 5 (2000) 584-589
    • (2000) J Arthroplast , vol.15 , Issue.5 , pp. 584-589
    • Estok, D.M.1    Harris, W.H.2
  • 9
    • 0030560956 scopus 로고    scopus 로고
    • A method for shape optimization of a hip prosthesis to maximize the fatigue life of the cement
    • Hedia H.S., Barton D.C., Fisher J., and Elmidany T.T. A method for shape optimization of a hip prosthesis to maximize the fatigue life of the cement. Med Eng Phys 18 (1996) 647-654
    • (1996) Med Eng Phys , vol.18 , pp. 647-654
    • Hedia, H.S.1    Barton, D.C.2    Fisher, J.3    Elmidany, T.T.4
  • 10
    • 0024947002 scopus 로고
    • Mathematical shape optimization of hip prosthesis design
    • Huiskes R., and Boeklagen R. Mathematical shape optimization of hip prosthesis design. J Biomechan 22 8/9 (1989) 793-804
    • (1989) J Biomechan , vol.22 , Issue.8-9 , pp. 793-804
    • Huiskes, R.1    Boeklagen, R.2
  • 11
    • 33947267578 scopus 로고    scopus 로고
    • Fatigue characteristics of metallic biomaterials
    • Niinomi M. Fatigue characteristics of metallic biomaterials. Int J Fatigue 29 (2007) 992-1000
    • (2007) Int J Fatigue , vol.29 , pp. 992-1000
    • Niinomi, M.1
  • 12
    • 0034317060 scopus 로고    scopus 로고
    • Fatigue of biomaterials: a review
    • Teoh S.H. Fatigue of biomaterials: a review. Int J Fatigue 22 (2000) 825-837
    • (2000) Int J Fatigue , vol.22 , pp. 825-837
    • Teoh, S.H.1
  • 13
    • 0004274342 scopus 로고    scopus 로고
    • Fatigue of materials
    • Cambridge University Press
    • Suresh S. Fatigue of materials. 2nd ed. (1998), Cambridge University Press
    • (1998) 2nd ed.
    • Suresh, S.1
  • 14
    • 0015569382 scopus 로고
    • Wear of solid phase formed HDPE in relation to the life of artificial hips and knees
    • Seedhom B.B., Dowson D., and Wright V. Wear of solid phase formed HDPE in relation to the life of artificial hips and knees. Wear 24 (1973) 35-51
    • (1973) Wear , vol.24 , pp. 35-51
    • Seedhom, B.B.1    Dowson, D.2    Wright, V.3
  • 15
    • 0019596362 scopus 로고
    • Wear of artificial joint materials. I. Friction and wear studies: vality of wear-screening protocols
    • Clarke I.C. Wear of artificial joint materials. I. Friction and wear studies: vality of wear-screening protocols. Eng Med 10 (1981) 115-122
    • (1981) Eng Med , vol.10 , pp. 115-122
    • Clarke, I.C.1
  • 16
    • 0345581246 scopus 로고    scopus 로고
    • Finite element simulation of anisotropic damage accumulation and creep in acrylic bone cement
    • Stolk J., Verdonschot N., Murphy B.P., Prendergast P.J., and Huiskes R. Finite element simulation of anisotropic damage accumulation and creep in acrylic bone cement. Eng Fract Mechan 71 (2004) 513-528
    • (2004) Eng Fract Mechan , vol.71 , pp. 513-528
    • Stolk, J.1    Verdonschot, N.2    Murphy, B.P.3    Prendergast, P.J.4    Huiskes, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.