메뉴 건너뛰기




Volumn 48, Issue 5, 2008, Pages 680-686

Association between pig activity and environmental factors in pig confinement buildings

Author keywords

Airborne bacteria; Airborne fungi; Ammonia; Dust; Hydrogen sulfide

Indexed keywords

AIR QUALITY; AIR SAMPLING; ATMOSPHERIC POLLUTION; BIOACTIVITY; BUILDING; DUST; ENVIRONMENTAL FACTOR; HYDROGEN SULFIDE; PIG; RELATIVE HUMIDITY; TEMPERATURE EFFECT;

EID: 41849092171     PISSN: 08161089     EISSN: None     Source Type: Journal    
DOI: 10.1071/EA06110     Document Type: Article
Times cited : (19)

References (26)
  • 2
    • 15744376299 scopus 로고    scopus 로고
    • The impact of different housing systems on health and welfare of grower and finisher pigs in Switzerland
    • doi:10.1016/j.prevetmed. 2005.01.004
    • Cagienard A, Regula G, Danuser J (2005) The impact of different housing systems on health and welfare of grower and finisher pigs in Switzerland. Preventive Veterinary Medicine 68, 49-61. doi:10.1016/j.prevetmed. 2005.01.004
    • (2005) Preventive Veterinary Medicine , vol.68 , pp. 49-61
    • Cagienard, A.1    Regula, G.2    Danuser, J.3
  • 5
  • 6
    • 0037160318 scopus 로고    scopus 로고
    • The separate and interactive effects of handling and environmental enrichment on the behaviour and welfare of growing pigs
    • doi:10.1016/S0168-1591(01)00199-X
    • Day JEL, Spooler HAM, Burfoot A, Chamberlain HL, Edwards SA (2002) The separate and interactive effects of handling and environmental enrichment on the behaviour and welfare of growing pigs. Applied Animal Behaviour Science 75, 177-192. doi:10.1016/S0168-1591(01)00199-X
    • (2002) Applied Animal Behaviour Science , vol.75 , pp. 177-192
    • Day, J.E.L.1    Spooler, H.A.M.2    Burfoot, A.3    Chamberlain, H.L.4    Edwards, S.A.5
  • 7
    • 0002919999 scopus 로고    scopus 로고
    • Setting maximum dust exposure levels for people and animals in livestock facilities. In 'Dust control in animal production facilities
    • Denmark, pp, Danish Institute of Agricultural Sciences, Dept of Agricultural Engineering: Horsens, Denmark
    • Donham KJ, Cumro D (1999) Setting maximum dust exposure levels for people and animals in livestock facilities. In 'Dust control in animal production facilities. Proceedings of a congress in Aarhus, Denmark'. pp. 93-110. (Danish Institute of Agricultural Sciences, Dept of Agricultural Engineering: Horsens, Denmark)
    • (1999) Proceedings of a congress in Aarhus , pp. 93-110
    • Donham, K.J.1    Cumro, D.2
  • 8
    • 0021215425 scopus 로고
    • Acute effects of the work environment on pulmonary functions of swine confinement workers
    • doi:10.1002/ajim. 4700050505
    • Donham KJ, Zavala DC, Merchant JA (1984) Acute effects of the work environment on pulmonary functions of swine confinement workers. American Journal of Industrial Medicine 5, 367-375. doi:10.1002/ajim. 4700050505
    • (1984) American Journal of Industrial Medicine , vol.5 , pp. 367-375
    • Donham, K.J.1    Zavala, D.C.2    Merchant, J.A.3
  • 10
    • 41849094866 scopus 로고    scopus 로고
    • Galbraith H, Robertson AM (1971) 'Effect of ventilation on the gas concentration in a part-stalled piggery.' R & D Studies 1, Scottish Farm Buildings Investigation Unit. pp. 17-28. (Agriculture Extension Publications: Deanston, Scotland)
    • Galbraith H, Robertson AM (1971) 'Effect of ventilation on the gas concentration in a part-stalled piggery.' R & D Studies 1, Scottish Farm Buildings Investigation Unit. pp. 17-28. (Agriculture Extension Publications: Deanston, Scotland)
  • 11
    • 0346903327 scopus 로고    scopus 로고
    • Factors affecting the release and concentration of dust in pig houses
    • doi:10.1006/jaer.1999.0476
    • Gustafsson G (1999) Factors affecting the release and concentration of dust in pig houses. Journal of Agricultural Engineering Research 74, 379-390. doi:10.1006/jaer.1999.0476
    • (1999) Journal of Agricultural Engineering Research , vol.74 , pp. 379-390
    • Gustafsson, G.1
  • 12
    • 25644460036 scopus 로고    scopus 로고
    • Temporal and spatial distributions of aerial contaminants in an enclosed pig building in winter
    • doi:10.1016/j.envres.2004.10. 004
    • Kim KY, Ko HJ, Lee KJ, Park JB, Kim CN (2005) Temporal and spatial distributions of aerial contaminants in an enclosed pig building in winter. Environmental Research 99, 150-157. doi:10.1016/j.envres.2004.10. 004
    • (2005) Environmental Research , vol.99 , pp. 150-157
    • Kim, K.Y.1    Ko, H.J.2    Lee, K.J.3    Park, J.B.4    Kim, C.N.5
  • 14
    • 41849139736 scopus 로고    scopus 로고
    • Morrison WD, Pirie PD, Perkins S, Braithwaite LA, Smith JH, Waterfall D, Doucett CM (1993) Gases and respirable dust in confinement buildings and the response of animals to such airborne contaminants. In 'Proceedings of International Livestock Environment Symposium IV, Warwick, England, 6-9 July'. pp. 735-746. (ASAE)
    • Morrison WD, Pirie PD, Perkins S, Braithwaite LA, Smith JH, Waterfall D, Doucett CM (1993) Gases and respirable dust in confinement buildings and the response of animals to such airborne contaminants. In 'Proceedings of International Livestock Environment Symposium IV, Warwick, England, 6-9 July'. pp. 735-746. (ASAE)
  • 15
    • 41849102793 scopus 로고    scopus 로고
    • Sampling and characterization of bioaerosols
    • National Institute for Occupational Safety and Health (, Eds AJ Paul, MP Schafer) pp, NIOSH Publications: Cincinnati, OH
    • National Institute for Occupational Safety and Health (1998) Sampling and characterization of bioaerosols. In 'Manual of analytical method'. (Eds AJ Paul, MP Schafer) pp. 254-255. (NIOSH Publications: Cincinnati, OH)
    • (1998) Manual of analytical method , pp. 254-255
  • 16
    • 41849124980 scopus 로고    scopus 로고
    • Nicks B, Marlier D, Canart B (1993) Air pollution levels in pig houses. In 'Proceedings of International Livestock Environment Symposium IV, Warwick, England, 6-9 July'. pp. 635-641. (ASAE)
    • Nicks B, Marlier D, Canart B (1993) Air pollution levels in pig houses. In 'Proceedings of International Livestock Environment Symposium IV, Warwick, England, 6-9 July'. pp. 635-641. (ASAE)
  • 18
    • 0034313238 scopus 로고    scopus 로고
    • Comparison between low-end discrete and high-end continuous measurements of air quality in swine buildings
    • Parbst KE, Keener KM, Heber AJ, Ni JQ (2000) Comparison between low-end discrete and high-end continuous measurements of air quality in swine buildings. Applied Engineering in Agriculture 16, 693-699.
    • (2000) Applied Engineering in Agriculture , vol.16 , pp. 693-699
    • Parbst, K.E.1    Keener, K.M.2    Heber, A.J.3    Ni, J.Q.4
  • 19
    • 41849083145 scopus 로고    scopus 로고
    • Pederson S (1993) Time based variation in airborne dust in respect to animal activity. In 'Proceedings of International Livestock Environment Symposium IV, Warwick, England, 6-9 July'. pp. 718-726. (ASAE)
    • Pederson S (1993) Time based variation in airborne dust in respect to animal activity. In 'Proceedings of International Livestock Environment Symposium IV, Warwick, England, 6-9 July'. pp. 718-726. (ASAE)
  • 21
    • 0020165069 scopus 로고
    • Microbial validation of ven filters
    • doi:10.1002/bit. 260260803
    • Robertson JH, Frieben WR (1984) Microbial validation of ven filters. Biotechnology and Bioengineering 26, 828-835. doi:10.1002/bit. 260260803
    • (1984) Biotechnology and Bioengineering , vol.26 , pp. 828-835
    • Robertson, J.H.1    Frieben, W.R.2
  • 22
    • 0004282518 scopus 로고    scopus 로고
    • SAS , Rel. 6.03, SAS Institute Inc, Cary, NC
    • SAS (2002) 'SAS/STAT user's guide.' Rel. 6.03. (SAS Institute Inc.: Cary, NC)
    • (2002) SAS/STAT user's guide
  • 23
    • 0034038160 scopus 로고    scopus 로고
    • Legislative methods for specifying stocking density and consequences for the welfare of finishing pigs
    • doi:10.1016/S0301- 6226(99)00152-9
    • Spoolder HAM, Edwards SA, Corning S (2000) Legislative methods for specifying stocking density and consequences for the welfare of finishing pigs. Livestock Production Science 64, 167-173. doi:10.1016/S0301- 6226(99)00152-9
    • (2000) Livestock Production Science , vol.64 , pp. 167-173
    • Spoolder, H.A.M.1    Edwards, S.A.2    Corning, S.3
  • 26
    • 0036276639 scopus 로고    scopus 로고
    • Measurement and analysis of dust spatial distribution in a mechanically ventilated pig building
    • doi:10.1006/bioe.2001.0014
    • Wang X, Zhang Y, Riskowski GL, Ellis M (2002) Measurement and analysis of dust spatial distribution in a mechanically ventilated pig building. Biosystems Engineering 81, 225-236. doi:10.1006/bioe.2001.0014
    • (2002) Biosystems Engineering , vol.81 , pp. 225-236
    • Wang, X.1    Zhang, Y.2    Riskowski, G.L.3    Ellis, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.