메뉴 건너뛰기




Volumn 87, Issue 1, 2008, Pages 65-73

Defining the margins in the radical radiotherapy of non-small cell lung cancer (NSCLC) with active breathing control (ABC) and the effect on physical lung parameters

Author keywords

Active breathing control; Non small cell lung cancer; Treatment margins

Indexed keywords

ADULT; AGED; ARTICLE; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DEVICE; ESOPHAGUS; FLUOROSCOPY; HUMAN; IMMOBILIZATION; INSPIRATORY CAPACITY; LUNG NON SMALL CELL CANCER; PHYSICAL PARAMETERS; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE FRACTIONATION; RESPIRATION CONTROL; THERAPY EFFECT;

EID: 41849089355     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2007.12.012     Document Type: Article
Times cited : (77)

References (35)
  • 2
    • 0033179899 scopus 로고    scopus 로고
    • Continuous, hyperfractionated, accelerated radiotherapy (CHART) versus conventional radiotherapy in non-small cell lung cancer: mature data from the randomised multicentre trial. CHART Steering committee
    • Saunders M., Dische S., Barrett A., Harvey A., Griffiths G., and Palmar M. Continuous, hyperfractionated, accelerated radiotherapy (CHART) versus conventional radiotherapy in non-small cell lung cancer: mature data from the randomised multicentre trial. CHART Steering committee. Radiother Oncol 52 (1999) 137-148
    • (1999) Radiother Oncol , vol.52 , pp. 137-148
    • Saunders, M.1    Dische, S.2    Barrett, A.3    Harvey, A.4    Griffiths, G.5    Palmar, M.6
  • 3
    • 0031688620 scopus 로고    scopus 로고
    • Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients
    • Kwa S.L., Lebesque J.V., Theuws J.C., et al. Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients. Int J Radiat Oncol Biol Phys 42 (1998) 1-9
    • (1998) Int J Radiat Oncol Biol Phys , vol.42 , pp. 1-9
    • Kwa, S.L.1    Lebesque, J.V.2    Theuws, J.C.3
  • 4
    • 0032840324 scopus 로고    scopus 로고
    • Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)
    • Graham M.V., Purdy J.A., Emami B., et al. Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC). Int J Radiat Oncol Biol Phys 45 (1999) 323-329
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 323-329
    • Graham, M.V.1    Purdy, J.A.2    Emami, B.3
  • 5
    • 0345269968 scopus 로고    scopus 로고
    • The relationship between local dose and loss of function for irradiated lung
    • Gopal R., Tucker S.L., Komaki R., et al. The relationship between local dose and loss of function for irradiated lung. Int J Radiat Oncol Biol Phys 56 (2003) 106-113
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 106-113
    • Gopal, R.1    Tucker, S.L.2    Komaki, R.3
  • 6
    • 0028843552 scopus 로고
    • Chemotherapy in non-small cell lung cancer: a meta-analysis using updated data on individual patients from 52 randomised clinical trials
    • Non-small Cell Lung Cancer Collaborative Group
    • Non-small Cell Lung Cancer Collaborative Group. Chemotherapy in non-small cell lung cancer: a meta-analysis using updated data on individual patients from 52 randomised clinical trials. BMJ 311 (1995) 899-909
    • (1995) BMJ , vol.311 , pp. 899-909
  • 7
    • 16644385726 scopus 로고    scopus 로고
    • Rowell NP, O'Rourke N P. Concurrent chemoradiotherapy in non-small cell lung cancer. Cochrane Database Syst Rev 2004;CD002140.
    • Rowell NP, O'Rourke N P. Concurrent chemoradiotherapy in non-small cell lung cancer. Cochrane Database Syst Rev 2004;CD002140.
  • 8
    • 0032858243 scopus 로고    scopus 로고
    • Phase III study of concurrent versus sequential thoracic radiotherapy in combination with mitomycin, vindesine, and cisplatin in unresectable stage III non-small-cell lung cancer
    • Furuse K., Fukuoka M., Kawahara M., et al. Phase III study of concurrent versus sequential thoracic radiotherapy in combination with mitomycin, vindesine, and cisplatin in unresectable stage III non-small-cell lung cancer. J Clin Oncol 17 (1999) 2692-2699
    • (1999) J Clin Oncol , vol.17 , pp. 2692-2699
    • Furuse, K.1    Fukuoka, M.2    Kawahara, M.3
  • 9
    • 0032823488 scopus 로고    scopus 로고
    • Chemoradiation for locally advanced, unresectable standard of care, emerging strategies
    • [discussion 1088, 1091-1074]
    • Gordon G.S., and Vokes E.E. Chemoradiation for locally advanced, unresectable standard of care, emerging strategies. Oncology (Williston Park) 13 (1999) 1075-1088 [discussion 1088, 1091-1074]
    • (1999) Oncology (Williston Park) , vol.13 , pp. 1075-1088
    • Gordon, G.S.1    Vokes, E.E.2
  • 10
    • 4444293137 scopus 로고    scopus 로고
    • Concurrent versus sequential chemoradiotherapy with cisplatin and vinorelbine in locally advanced non-small cell lung cancer: a randomized study
    • Zatloukal P., Petruzelka L., Zemanova M., et al. Concurrent versus sequential chemoradiotherapy with cisplatin and vinorelbine in locally advanced non-small cell lung cancer: a randomized study. Lung Cancer 46 (2004) 87-98
    • (2004) Lung Cancer , vol.46 , pp. 87-98
    • Zatloukal, P.1    Petruzelka, L.2    Zemanova, M.3
  • 11
    • 4143113551 scopus 로고    scopus 로고
    • Combined modality trials of the Cancer and Leukemia Group B in stage III non-small-cell lung cancer: analysis of factors influencing survival and toxicity
    • Socinski M.A., Zhang C., Herndon II J.E., et al. Combined modality trials of the Cancer and Leukemia Group B in stage III non-small-cell lung cancer: analysis of factors influencing survival and toxicity. Ann Oncol 15 (2004) 1033-1041
    • (2004) Ann Oncol , vol.15 , pp. 1033-1041
    • Socinski, M.A.1    Zhang, C.2    Herndon II, J.E.3
  • 12
    • 41849095762 scopus 로고    scopus 로고
    • ICRU. ICRU Report 50. Prescribing, recording and reporting photon beam therapy. Bethesda, MD: International Commission on Radiation Units and Measurements; 1993.
    • ICRU. ICRU Report 50. Prescribing, recording and reporting photon beam therapy. Bethesda, MD: International Commission on Radiation Units and Measurements; 1993.
  • 13
    • 41849119619 scopus 로고    scopus 로고
    • ICRU. ICRU Report 62 (Supplement to ICRU Report 50). Prescribing, recording and reporting photon beam therapy. Bethesda MD: International Commission on Radiation Units and Measurements; 1993.
    • ICRU. ICRU Report 62 (Supplement to ICRU Report 50). Prescribing, recording and reporting photon beam therapy. Bethesda MD: International Commission on Radiation Units and Measurements; 1993.
  • 14
    • 0033013520 scopus 로고    scopus 로고
    • The use of active breathing control (ABC) to reduce margin for breathing motion
    • Wong J.W., Sharpe M.B., Jaffray D.A., et al. The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys 44 (1999) 911-919
    • (1999) Int J Radiat Oncol Biol Phys , vol.44 , pp. 911-919
    • Wong, J.W.1    Sharpe, M.B.2    Jaffray, D.A.3
  • 15
    • 0344394980 scopus 로고    scopus 로고
    • Reproducibility of lung tumor position and reduction of lung mass within the planning target volume using active breathing control (ABC)
    • Cheung P.C., Sixel K.E., Tirona R., and Ung Y.C. Reproducibility of lung tumor position and reduction of lung mass within the planning target volume using active breathing control (ABC). Int J Radiat Oncol Biol Phys 57 (2003) 1437-1442
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1437-1442
    • Cheung, P.C.1    Sixel, K.E.2    Tirona, R.3    Ung, Y.C.4
  • 16
    • 0141504127 scopus 로고    scopus 로고
    • Validation of active breathing control in patients with non-small-cell lung cancer to be treated with CHARTWEL
    • Wilson E.M., Williams F.J., Lyn B.E., Wong J.W., and Aird E.G. Validation of active breathing control in patients with non-small-cell lung cancer to be treated with CHARTWEL. Int J Radiat Oncol Biol Phys 57 (2003) 864-874
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 864-874
    • Wilson, E.M.1    Williams, F.J.2    Lyn, B.E.3    Wong, J.W.4    Aird, E.G.5
  • 17
    • 12844278157 scopus 로고    scopus 로고
    • Nonrigid registration method to assess reproducibility of breath-holding with ABC in lung cancer
    • Sarrut D., Boldea V., Ayadi M., et al. Nonrigid registration method to assess reproducibility of breath-holding with ABC in lung cancer. Int J Radiat Oncol Biol Phys 61 (2005) 594-607
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 594-607
    • Sarrut, D.1    Boldea, V.2    Ayadi, M.3
  • 18
    • 0346364988 scopus 로고    scopus 로고
    • Application of the spirometer in respiratory gated radiotherapy
    • Zhang T., Keller H., O'Brien M.J., Mackie T.R., and Paliwal B. Application of the spirometer in respiratory gated radiotherapy. Med Phys 30 (2003) 3165-3171
    • (2003) Med Phys , vol.30 , pp. 3165-3171
    • Zhang, T.1    Keller, H.2    O'Brien, M.J.3    Mackie, T.R.4    Paliwal, B.5
  • 19
    • 0842306297 scopus 로고    scopus 로고
    • Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment
    • Mageras G.S., and Yorke E. Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment. Semin Radiat Oncol 14 (2004) 65-75
    • (2004) Semin Radiat Oncol , vol.14 , pp. 65-75
    • Mageras, G.S.1    Yorke, E.2
  • 20
    • 7244242297 scopus 로고    scopus 로고
    • Respiration tracking in radiosurgery
    • Schweikard A., Shiomi H., and Adler J. Respiration tracking in radiosurgery. Med Phys 31 (2004) 2738-2741
    • (2004) Med Phys , vol.31 , pp. 2738-2741
    • Schweikard, A.1    Shiomi, H.2    Adler, J.3
  • 21
    • 0842306308 scopus 로고    scopus 로고
    • Errors and margins in radiotherapy
    • van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol 14 (2004) 52-64
    • (2004) Semin Radiat Oncol , vol.14 , pp. 52-64
    • van Herk, M.1
  • 22
    • 33748536386 scopus 로고    scopus 로고
    • Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients
    • Wolthaus J.W.H., Schneider C., Sonke J.-J., et al. Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. Int J Radiat Oncol Biol Phys 65 (2006) 1560-1571
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 1560-1571
    • Wolthaus, J.W.H.1    Schneider, C.2    Sonke, J.-J.3
  • 23
    • 29144442021 scopus 로고    scopus 로고
    • Effects of averaging over motion and the resulting systematic errors in radiation therapy
    • Evans P.M., Coolens C., and Nioutsikou E. Effects of averaging over motion and the resulting systematic errors in radiation therapy. Phys Med Biol 51 (2006) N1-N7
    • (2006) Phys Med Biol , vol.51
    • Evans, P.M.1    Coolens, C.2    Nioutsikou, E.3
  • 24
    • 41849124329 scopus 로고    scopus 로고
    • BIR. Geometric uncertainties in radiotherapy: defining the planning target volume. London: The British Institute of Radiology Working Party; 2003.
    • BIR. Geometric uncertainties in radiotherapy: defining the planning target volume. London: The British Institute of Radiology Working Party; 2003.
  • 25
    • 0036534905 scopus 로고    scopus 로고
    • Inclusion of geometric uncertainties in treatment plan evaluation
    • van Herk M., Remeijer P., and Lebesque J.V. Inclusion of geometric uncertainties in treatment plan evaluation. Int J Radiat Oncol Biol Phys 52 (2002) 1407-1422
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 1407-1422
    • van Herk, M.1    Remeijer, P.2    Lebesque, J.V.3
  • 26
    • 0036229217 scopus 로고    scopus 로고
    • Margins for geometric uncertainty around organs at risk in radiotherapy
    • McKenzie A., van Herk M., and Mijnheer B. Margins for geometric uncertainty around organs at risk in radiotherapy. Radiother Oncol 62 (2002) 299-307
    • (2002) Radiother Oncol , vol.62 , pp. 299-307
    • McKenzie, A.1    van Herk, M.2    Mijnheer, B.3
  • 27
    • 0037249948 scopus 로고    scopus 로고
    • Portal imaging to assess set-up errors, tumour motion and tumour shrinkage during conformal radiotherapy of non-small cell lung cancer
    • Erridge S.C., Seppenwoolde Y., Muller S.H., et al. Portal imaging to assess set-up errors, tumour motion and tumour shrinkage during conformal radiotherapy of non-small cell lung cancer. Radiother Oncol 66 (2003) 75-85
    • (2003) Radiother Oncol , vol.66 , pp. 75-85
    • Erridge, S.C.1    Seppenwoolde, Y.2    Muller, S.H.3
  • 28
    • 0037100122 scopus 로고    scopus 로고
    • Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
    • Seppenwoolde Y., Shirato H., Kitamura K., et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 53 (2002) 822-834
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 822-834
    • Seppenwoolde, Y.1    Shirato, H.2    Kitamura, K.3
  • 29
    • 0031895830 scopus 로고    scopus 로고
    • Electronic portal imaging with on-line correction of setup error in thoracic irradiation: clinical evaluation
    • van de Steene J., van den Heuvel F., Bel A., et al. Electronic portal imaging with on-line correction of setup error in thoracic irradiation: clinical evaluation. Int J Radiat Oncol Biol Phys 40 (1998) 967-976
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 967-976
    • van de Steene, J.1    van den Heuvel, F.2    Bel, A.3
  • 30
    • 0032899184 scopus 로고    scopus 로고
    • Setup reproducibility in radiation therapy for lung cancer: a comparison between T-bar and expanded foam immobilization devices
    • Halperin R., Roa W., Field M., Hanson J., and Murray B. Setup reproducibility in radiation therapy for lung cancer: a comparison between T-bar and expanded foam immobilization devices. Int J Radiat Oncol Biol Phys 43 (1999) 211-216
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 211-216
    • Halperin, R.1    Roa, W.2    Field, M.3    Hanson, J.4    Murray, B.5
  • 31
    • 0345435973 scopus 로고    scopus 로고
    • An analysis of anatomic landmark mobility and setup deviations in radiotherapy for lung cancer
    • Samson M.J., van Sornsen de Koste J.R., de Boer H.C., et al. An analysis of anatomic landmark mobility and setup deviations in radiotherapy for lung cancer. Int J Radiat Oncol Biol Phys 43 (1999) 827-832
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 827-832
    • Samson, M.J.1    van Sornsen de Koste, J.R.2    de Boer, H.C.3
  • 32
    • 0035252342 scopus 로고    scopus 로고
    • Set-up verification using portal imaging: review of current clinical practice
    • Hurkmans C.W., Remeijer P., Lebesque J.V., and Mijnheer B.J. Set-up verification using portal imaging: review of current clinical practice. Radiother Oncol 58 (2001) 105-120
    • (2001) Radiother Oncol , vol.58 , pp. 105-120
    • Hurkmans, C.W.1    Remeijer, P.2    Lebesque, J.V.3    Mijnheer, B.J.4
  • 33
    • 0347624514 scopus 로고    scopus 로고
    • Comparison of the efficacy and acute toxicity of weekly versus daily chemoradiotherapy for non-small-cell lung cancer: a meta-analysis
    • Rakovitch E., Tsao M., Ung Y., Pignol J.P., Cheung P., and Chow E. Comparison of the efficacy and acute toxicity of weekly versus daily chemoradiotherapy for non-small-cell lung cancer: a meta-analysis. Int J Radiat Oncol Biol Phys 58 (2004) 196-203
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , pp. 196-203
    • Rakovitch, E.1    Tsao, M.2    Ung, Y.3    Pignol, J.P.4    Cheung, P.5    Chow, E.6
  • 34
    • 33644666024 scopus 로고    scopus 로고
    • Concomitant radio-chemotherapy based on platin compounds in patients with locally advanced non-small cell lung cancer (NSCLC): a meta-analysis of individual data from 1764 patients
    • Auperin A., Le Pechoux C., Pignon J.P., et al. Concomitant radio-chemotherapy based on platin compounds in patients with locally advanced non-small cell lung cancer (NSCLC): a meta-analysis of individual data from 1764 patients. Ann Oncol 3 (2006) 473-483
    • (2006) Ann Oncol , vol.3 , pp. 473-483
    • Auperin, A.1    Le Pechoux, C.2    Pignon, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.