메뉴 건너뛰기




Volumn 17, Issue 3, 2007, Pages 219-223

Ultrasonographically checking the sectioning of the transverse carpal ligament during carpal tunnel surgery with limited uni skin incisions

Author keywords

Carpal tunnel surgery; Intraoperative ultrasonography; Uni skin incision

Indexed keywords

ARTICLE; CARPAL TUNNEL SYNDROME; CLINICAL ARTICLE; CONTROLLED STUDY; ECHOGRAPHY; FEMALE; HUMAN; INTRAOPERATIVE PERIOD; LIGAMENT SURGERY; MEDIAN NERVE; PREOPERATIVE EVALUATION; SKIN INCISION; SURGICAL TECHNIQUE; ULTRASOUND SCANNER; CLINICAL TRIAL; INSTRUMENTATION; LIGAMENT; METHODOLOGY; MINIMALLY INVASIVE SURGERY; PATIENT MONITORING;

EID: 41749103392     PISSN: 10195149     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (18)
  • 1
    • 0028884331 scopus 로고
    • Sequela of carpal tunnel surgery: Rationale for design of a surgical approach
    • Abdullah AF, Wolber PH, Ditto EW. Sequela of carpal tunnel surgery: rationale for design of a surgical approach. Neurosurgery 1995; 37: 931-36.
    • (1995) Neurosurgery , vol.37 , pp. 931-936
    • Abdullah, A.F.1    Wolber, P.H.2    Ditto, E.W.3
  • 2
    • 0027157213 scopus 로고
    • An open twin incision technique of carpal tunnel decompression with reduced incidence of scar tenderness
    • Biyani A, Downes EM. An open twin incision technique of carpal tunnel decompression with reduced incidence of scar tenderness. J Hand Surg 1993; 18: 331-34.
    • (1993) J Hand Surg , vol.18 , pp. 331-334
    • Biyani, A.1    Downes, E.M.2
  • 3
    • 0027958111 scopus 로고
    • Minimal incision open carpal tunnel decompression
    • Bromley GS. Minimal incision open carpal tunnel decompression. J Hand Surg 1994; 19: 119-20.
    • (1994) J Hand Surg , vol.19 , pp. 119-120
    • Bromley, G.S.1
  • 4
    • 0025758424 scopus 로고
    • Symptoms may return after carpal tunnel surgery
    • Cotton P. Symptoms may return after carpal tunnel surgery. JAMA 1991; 265: 1922-25.
    • (1991) JAMA , vol.265 , pp. 1922-1925
    • Cotton, P.1
  • 5
    • 0034151862 scopus 로고    scopus 로고
    • Endoscopic treatment of the carpal tunnel syndrome: Review of the recent literature
    • Delaere O, Bouffioux N, Hoang P. Endoscopic treatment of the carpal tunnel syndrome: review of the recent literature. Acta Chir Belg 2000; 100: 54-7.
    • (2000) Acta Chir Belg , vol.100 , pp. 54-57
    • Delaere, O.1    Bouffioux, N.2    Hoang, P.3
  • 6
    • 0030226268 scopus 로고    scopus 로고
    • Two stitch carpal tunnel surgery. A mini-incision technique
    • Frank CE. "Two stitch" carpal tunnel surgery. A mini-incision technique. Am J Orthop 1996; 25: 650.
    • (1996) Am J Orthop , vol.25 , pp. 650
    • Frank, C.E.1
  • 7
    • 33847008026 scopus 로고    scopus 로고
    • Minimally invasive carpal tunnel decompression using the knifelight
    • Hwang Py, Ho CL. Minimally invasive carpal tunnel decompression using the knifelight. Neurosurgery 2007; 60: 162-9.
    • (2007) Neurosurgery , vol.60 , pp. 162-169
    • Hwang, P.1    Ho, C.L.2
  • 8
    • 33646749120 scopus 로고    scopus 로고
    • Microsurgical open mini uniskin incision technique in the surgical treatment of carpal tunnel syndrome
    • Keramettin A, Cengiz C, Nilgun C, Ayhan B. Microsurgical open mini uniskin incision technique in the surgical treatment of carpal tunnel syndrome. Neurol India 2006; 54(1):64-7.
    • (2006) Neurol India , vol.54 , Issue.1 , pp. 64-67
    • Keramettin, A.1    Cengiz, C.2    Nilgun, C.3    Ayhan, B.4
  • 9
    • 0031930792 scopus 로고    scopus 로고
    • Safe carpal tunnel release via a limited palmar incision
    • Lee WP, Strickland JW. Safe carpal tunnel release via a limited palmar incision. Plast Reconstr Surg 1998; 101: 418-24.
    • (1998) Plast Reconstr Surg , vol.101 , pp. 418-424
    • Lee, W.P.1    Strickland, J.W.2
  • 10
    • 0030885916 scopus 로고    scopus 로고
    • Ultrasonographically assisted carpal tunnel release
    • Nakamichi K, Tachibana S. Ultrasonographically assisted carpal tunnel release. J Hand Surg (Am) 1997, 22 (5): 853-62.
    • (1997) J Hand Surg (Am) , vol.22 , Issue.5 , pp. 853-862
    • Nakamichi, K.1    Tachibana, S.2
  • 11
    • 0031116764 scopus 로고    scopus 로고
    • Carpal tunnel release using minimally invazive technique
    • Nathan PA. Carpal tunnel release using minimally invazive technique. Plast Reconstr Surg 1997; 99: 1195-6.
    • (1997) Plast Reconstr Surg , vol.99 , pp. 1195-1196
    • Nathan, P.A.1
  • 12
    • 0026326686 scopus 로고
    • Carpal tunnel syndrome: Surgical treatment using the Paine retinaculatome
    • Pagnanelli DM, Barrer SJ. Carpal tunnel syndrome: surgical treatment using the Paine retinaculatome. J Neurosurg 1991; 75: 77-81.
    • (1991) J Neurosurg , vol.75 , pp. 77-81
    • Pagnanelli, D.M.1    Barrer, S.J.2
  • 13
    • 0141926040 scopus 로고
    • Entrapment neuropathies
    • Wilkins R, Rengachary S eds, New York, McGraw-Hill Book Co, pp
    • Rengachary S. Entrapment neuropathies, in Wilkins R, Rengachary S (eds): Neurosurgery. New York, McGraw-Hill Book Co., pp 1771-1776, 1985.
    • (1985) Neurosurgery , pp. 1771-1776
    • Rengachary, S.1
  • 14
    • 0033655372 scopus 로고    scopus 로고
    • Results of different incisions in treatment of carpal tunnel syndrome
    • Schmidt W, Gruber AA, Hammer R. Results of different incisions in treatment of carpal tunnel syndrome. Handchir Mikrochir Plast Chir 2000; 32: 67-9.
    • (2000) Handchir Mikrochir Plast Chir , vol.32 , pp. 67-69
    • Schmidt, W.1    Gruber, A.A.2    Hammer, R.3
  • 15
    • 0029061565 scopus 로고
    • Microsurgical carpal tunnel release. Technique and application
    • Scott S. Microsurgical carpal tunnel release. Technique and application. Neurosurgery 1995; 37: 66-70.
    • (1995) Neurosurgery , vol.37 , pp. 66-70
    • Scott, S.1
  • 17
    • 0027942759 scopus 로고
    • Double incision open technique for carpal tunnel release: An alternative to endoscopic release
    • Wilson KM. Double incision open technique for carpal tunnel release: an alternative to endoscopic release. J Hand Surg (Am) 1994; 19: 907-12.
    • (1994) J Hand Surg (Am) , vol.19 , pp. 907-912
    • Wilson, K.M.1
  • 18
    • 0026573960 scopus 로고
    • Double incision for operation of carpal tunnel syndrome-14 years experience
    • Zimmerli W. Double incision for operation of carpal tunnel syndrome-14 years experience. Helv Chir Acta 1992; 58: 395-400.
    • (1992) Helv Chir Acta , vol.58 , pp. 395-400
    • Zimmerli, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.