Volumn 71, Issue 1 SUPPL., 2008, Pages

Multileaf Collimator Characteristics and Reliability Requirements for IMRT Elekta System

Author keywords

Backup jaw; Elekta; MLC; Multileaf collimator; Quality assurance

Indexed keywords

OPTICAL COLLIMATORS; PARAMETER ESTIMATION; PARTICLE ACCELERATORS; QUALITY ASSURANCE; RADIATION DETECTORS; RADIOTHERAPY;

EID: 41749099695     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2007.07.2392     Document Type: Article
Times cited : (10)

References (14)
  • 1
    • 0000999047 scopus 로고
    • Synchronous field shaping in rotational megavoltage therapy
    • Proimus B.S. Synchronous field shaping in rotational megavoltage therapy. Radiology 74 (1960) 753-757
    • (1960) Radiology , vol.74 , pp. 753-757
    • Proimus, B.S.1
  • 2
    • 0002597627 scopus 로고
    • Synchronous field shaping and protection in 2-million volt rotational therapy
    • Trump J.G., Wright K.A., Smedal M.I., et al. Synchronous field shaping and protection in 2-million volt rotational therapy. Radiology 76 (1961) 275
    • (1961) Radiology , vol.76 , pp. 275
    • Trump, J.G.1    Wright, K.A.2    Smedal, M.I.3
  • 3
    • 0002319554 scopus 로고
    • Conformation radiotherapy rotation techniques as applied to radiography
    • Takahashi S. Conformation radiotherapy rotation techniques as applied to radiography. Acta Radiol Suppl (1965) 242
    • (1965) Acta Radiol Suppl , pp. 242
    • Takahashi, S.1
  • 6
    • 41749120248 scopus 로고
    • Commissioning of a multisegment collimator. Abstract of proceedings: Dosimetry protocols, quality assurance and asymmetric collimators
    • Jordan T.J. Commissioning of a multisegment collimator. Abstract of proceedings: Dosimetry protocols, quality assurance and asymmetric collimators. Phys Med Biol 36 (1991) 669-670
    • (1991) Phys Med Biol , vol.36 , pp. 669-670
    • Jordan, T.J.1
  • 8
    • 41749091038 scopus 로고    scopus 로고
    • Elekta Oncology Systems Ltd., Crawley, West Sussex, United Kingdom p. 12-15
    • Precise Treatment System Clinical Mode Users Manual R50 (2003), Elekta Oncology Systems Ltd., Crawley, West Sussex, United Kingdom p. 12-15
    • (2003) Precise Treatment System Clinical Mode Users Manual R50
  • 9
    • 0028346915 scopus 로고
    • The design and performance characteristics of a multileaf collimator
    • Jordan T.J., and Williams P.C. The design and performance characteristics of a multileaf collimator. Phys Med Biol 39 (1994) 231-251
    • (1994) Phys Med Biol , vol.39 , pp. 231-251
    • Jordan, T.J.1    Williams, P.C.2
  • 10
    • 0141849089 scopus 로고    scopus 로고
    • Rounded end multi-leaf penumbral measurements with radiochromic film
    • Butson M,Yu P.K.N., and Cheung T. Rounded end multi-leaf penumbral measurements with radiochromic film. Phys Med Biol 48 (2003) N247-N252
    • (2003) Phys Med Biol , vol.48
    • Butson M,Yu, P.K.N.1    Cheung, T.2
  • 11
    • 0037150875 scopus 로고    scopus 로고
    • A dosimetric comparison of various multileaf collimators
    • Huq M.S., Das I.J., Steinberg T., et al. A dosimetric comparison of various multileaf collimators. Phys Med Biol 47 (2002) N159-N170
    • (2002) Phys Med Biol , vol.47
    • Huq, M.S.1    Das, I.J.2    Steinberg, T.3
  • 12
    • 0029901714 scopus 로고    scopus 로고
    • Dosimetric considerations for a multileaf collimator system
    • Palta J.R., Yeung D.K., and Frouhar V. Dosimetric considerations for a multileaf collimator system. Med Phys 23 (1996) 1219-1224
    • (1996) Med Phys , vol.23 , pp. 1219-1224
    • Palta, J.R.1    Yeung, D.K.2    Frouhar, V.3
  • 13
    • 0030667163 scopus 로고    scopus 로고
    • An equivalent square field formula for determining head scatter factors of rectangular fields
    • Kim S., Zhu T.C., and Palta J.R. An equivalent square field formula for determining head scatter factors of rectangular fields. Med Phys 24 (1997) 1770-1774
    • (1997) Med Phys , vol.24 , pp. 1770-1774
    • Kim, S.1    Zhu, T.C.2    Palta, J.R.3
  • 14
    • 3242781030 scopus 로고    scopus 로고
    • An accurate calibration method of the multileaf collimator valid for conformal and intensity modulated radiation treatments
    • Sastre-Padro M., Heide U.A., and Welleweerd H. An accurate calibration method of the multileaf collimator valid for conformal and intensity modulated radiation treatments. Phys Med Biol 49 (2004) 2631-2643
    • (2004) Phys Med Biol , vol.49 , pp. 2631-2643
    • Sastre-Padro, M.1    Heide, U.A.2    Welleweerd, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.