메뉴 건너뛰기




Volumn 32, Issue 2, 2008, Pages 313-319

Difference in enhancement between spin echo and 3-dimensional fast spoiled gradient recalled acquisition in steady state magnetic resonance imaging of brain metastasis at 3-T magnetic resonance imaging

Author keywords

FSPGR; MRI; Spin echo

Indexed keywords

IMAGE ENHANCEMENT; MAGNETISM; PATHOLOGY; RESONANCE; SPIN POLARIZATION;

EID: 41749092576     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/RCT.0b013e318074fd9d     Document Type: Article
Times cited : (43)

References (21)
  • 2
    • 34249902314 scopus 로고    scopus 로고
    • Optimizing intracranial metastasis detection for stereotactic radiosurgery
    • Engh JA, Flickinger JC, Niranjan A, et al. Optimizing intracranial metastasis detection for stereotactic radiosurgery. Stereotact Funct Neurosurg. 2007;86:162-168.
    • (2007) Stereotact Funct Neurosurg , vol.86 , pp. 162-168
    • Engh, J.A.1    Flickinger, J.C.2    Niranjan, A.3
  • 3
    • 0026701185 scopus 로고
    • Uses and limitations of spoiled gradient-refocused imaging in the evaluation of suspected intracranial tumors
    • Rand S, Maravilla KR. Uses and limitations of spoiled gradient-refocused imaging in the evaluation of suspected intracranial tumors. Top Magn Reson Imaging. 1992;4:7-16.
    • (1992) Top Magn Reson Imaging , vol.4 , pp. 7-16
    • Rand, S.1    Maravilla, K.R.2
  • 4
    • 0025105879 scopus 로고
    • Comparison of spin echo T1-weighted and FLASH 90 degrees gadolinium-enhanced magnetic resonance imaging in the detection of cerebral metastases
    • Cherryman G, Golfieri R. Comparison of spin echo T1-weighted and FLASH 90 degrees gadolinium-enhanced magnetic resonance imaging in the detection of cerebral metastases. Br J Radiol. 1990;63:712-715.
    • (1990) Br J Radiol , vol.63 , pp. 712-715
    • Cherryman, G.1    Golfieri, R.2
  • 5
    • 0027952919 scopus 로고
    • Comparison of lesion enhancement on spin-echo and gradient-echo images
    • Chappell PM, Pelc NJ, Foo TK, et al. Comparison of lesion enhancement on spin-echo and gradient-echo images. AJNR Am J Neuroradiol. 1994;15:37-44.
    • (1994) AJNR Am J Neuroradiol , vol.15 , pp. 37-44
    • Chappell, P.M.1    Pelc, N.J.2    Foo, T.K.3
  • 6
    • 0028031789 scopus 로고
    • Lesion enhancement in radio-frequency spoiled gradient-echo imaging: Theory, experimental evaluation, and clinical implications
    • Rand S, Maravilla KR, Schmiedl U. Lesion enhancement in radio-frequency spoiled gradient-echo imaging: theory, experimental evaluation, and clinical implications. AJNR Am J Neuroradiol. 1994;15:27-35.
    • (1994) AJNR Am J Neuroradiol , vol.15 , pp. 27-35
    • Rand, S.1    Maravilla, K.R.2    Schmiedl, U.3
  • 7
    • 0027665072 scopus 로고
    • Theoretical analysis of gadopentetate dimeglumine enhancement in T1-weighted imaging of the brain: Comparison of two-dimensional spin-echo and three-dimensional gradient-echo sequences
    • Mugler JP 3rd, Brookeman JR. Theoretical analysis of gadopentetate dimeglumine enhancement in T1-weighted imaging of the brain: comparison of two-dimensional spin-echo and three-dimensional gradient-echo sequences. J Magn Reson Imaging. 1993;3:761-769.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 761-769
    • Mugler 3rd, J.P.1    Brookeman, J.R.2
  • 8
    • 0031310459 scopus 로고    scopus 로고
    • How much contrast is enough? Dependence of enhancement on field strength and MR pulse sequence
    • Elster AD. How much contrast is enough? Dependence of enhancement on field strength and MR pulse sequence. Eur Radiol. 1997;suppl 5:S276-S280.
    • (1997) Eur Radiol , Issue.SUPPL. 5
    • Elster, A.D.1
  • 9
    • 0029126381 scopus 로고
    • MR imaging of the brain: Comparison of gradient-echo and spine-echo pulse sequences
    • Pui MH, Fok ECM. MR imaging of the brain: comparison of gradient-echo and spine-echo pulse sequences. AJR Am J Roentgenol. 1995;165:959-962.
    • (1995) AJR Am J Roentgenol , vol.165 , pp. 959-962
    • Pui, M.H.1    Fok, E.C.M.2
  • 10
    • 0026955704 scopus 로고
    • Intracranial lesion enhancement with gadolinium: T1-weighted spin-echo versus three-dimensional Fourier transform gradient-echo MR imaging
    • Mirowitz SA. Intracranial lesion enhancement with gadolinium: T1-weighted spin-echo versus three-dimensional Fourier transform gradient-echo MR imaging. Radiology. 1992;185:529-534.
    • (1992) Radiology , vol.185 , pp. 529-534
    • Mirowitz, S.A.1
  • 11
    • 0030137094 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: Comparison of T1-weighted spin-echo and 3D gradient-echo sequences
    • Li D, Haacke EM, Tarr RW, et al. Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: comparison of T1-weighted spin-echo and 3D gradient-echo sequences. J Magn Reson Imaging. 1996;6:415-424.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 415-424
    • Li, D.1    Haacke, E.M.2    Tarr, R.W.3
  • 12
    • 0038360756 scopus 로고    scopus 로고
    • Spoiled gradient recalled acquisition in the steady state technique is superior to conventional postcontrast spin echo technique for magnetic resonance imaging detection of adrenocorticotropin-secreting pituitary tumors
    • Patrons N, Bulakbasi N, Stratakis CA, et al. Spoiled gradient recalled acquisition in the steady state technique is superior to conventional postcontrast spin echo technique for magnetic resonance imaging detection of adrenocorticotropin-secreting pituitary tumors. J Clin Endocrinol Metab. 2003;88:1565-1569.
    • (2003) J Clin Endocrinol Metab , vol.88 , pp. 1565-1569
    • Patrons, N.1    Bulakbasi, N.2    Stratakis, C.A.3
  • 13
    • 0036119659 scopus 로고    scopus 로고
    • Magnetic resonance imaging contrast enhancement of brain tumors at 3 Tesla versus 1.5 Tesla
    • Nobauer-Huhmann I-M, Ba-Ssalamah A, Mlynarik V, et al. Magnetic resonance imaging contrast enhancement of brain tumors at 3 Tesla versus 1.5 Tesla. Invest Radiol. 2002;3:114-119.
    • (2002) Invest Radiol , vol.3 , pp. 114-119
    • Nobauer-Huhmann, I.-M.1    Ba-Ssalamah, A.2    Mlynarik, V.3
  • 14
    • 0037561210 scopus 로고    scopus 로고
    • Effect of contrast dose and field strength in the magnetic resonance detection of brain metastases
    • Ba-Ssalamah A, Nobauer-Huhmann IM, Pinker K, et al. Effect of contrast dose and field strength in the magnetic resonance detection of brain metastases. Invest Radiol. 2003;38:415-422.
    • (2003) Invest Radiol , vol.38 , pp. 415-422
    • Ba-Ssalamah, A.1    Nobauer-Huhmann, I.M.2    Pinker, K.3
  • 15
    • 0022967683 scopus 로고
    • Time-dependent changes in image contrast in brain tumors after gadolinium-DTPA
    • Schorner W, Laniado M, Niendorf HP, et al. Time-dependent changes in image contrast in brain tumors after gadolinium-DTPA. AJNR Am J Neuroradiol. 1986;7:1013-1020.
    • (1986) AJNR Am J Neuroradiol , vol.7 , pp. 1013-1020
    • Schorner, W.1    Laniado, M.2    Niendorf, H.P.3
  • 16
    • 0028877763 scopus 로고
    • The effect of contrast dose, imaging time, and lesion size in the MR detection of intracerebral metastasis
    • Yuh WTC, Tali ET, Nguyen HD, et al. The effect of contrast dose, imaging time, and lesion size in the MR detection of intracerebral metastasis. AJNR Am J Neuroradiol. 1995;16:378-380.
    • (1995) AJNR Am J Neuroradiol , vol.16 , pp. 378-380
    • Yuh, W.T.C.1    Tali, E.T.2    Nguyen, H.D.3
  • 17
    • 0030637353 scopus 로고    scopus 로고
    • Brain lesion contrast in MR imaging. Dependence on field strength and concentration of gadodiamide injection in patients and phantoms
    • Akeson P, Vikhoff B, Stahlberg F, et al. Brain lesion contrast in MR imaging. Dependence on field strength and concentration of gadodiamide injection in patients and phantoms. Acta Radiol. 1997;38:14-18.
    • (1997) Acta Radiol , vol.38 , pp. 14-18
    • Akeson, P.1    Vikhoff, B.2    Stahlberg, F.3
  • 18
    • 33744804580 scopus 로고    scopus 로고
    • The optimal use of contrast agents at high field MRI
    • Trattnig S, Pinker K, Ba-Ssalamah A, et al. The optimal use of contrast agents at high field MRI. Eur Radiol. 2006;16:1280-1287.
    • (2006) Eur Radiol , vol.16 , pp. 1280-1287
    • Trattnig, S.1    Pinker, K.2    Ba-Ssalamah, A.3
  • 19
    • 0027968745 scopus 로고
    • Magnetization transfer imaging: Practical aspects and clinical applications
    • Wolff S, Balaban RS. Magnetization transfer imaging: Practical aspects and clinical applications. Radiology. 1994;192:593-599.
    • (1994) Radiology , vol.192 , pp. 593-599
    • Wolff, S.1    Balaban, R.S.2
  • 20
    • 0032880622 scopus 로고    scopus 로고
    • Magnetization transfer imaging of the brain: A quantitative comparison of results obtained at 1.5T and 4.0T
    • Duvvuri U, Roberts DA, Leigh JS, et al. Magnetization transfer imaging of the brain: a quantitative comparison of results obtained at 1.5T and 4.0T. J Magn Reson Imaging. 1999;10:527-532.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 527-532
    • Duvvuri, U.1    Roberts, D.A.2    Leigh, J.S.3
  • 21
    • 23044458347 scopus 로고    scopus 로고
    • Efficacy of contrast medium use for neuroimaging at 3.0T
    • Fishbach F, Bruhn H, Pech M, et al. Efficacy of contrast medium use for neuroimaging at 3.0T. J Comput Assist Tomogr. 2005;29:499-505.
    • (2005) J Comput Assist Tomogr , vol.29 , pp. 499-505
    • Fishbach, F.1    Bruhn, H.2    Pech, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.