-
3
-
-
1242338927
-
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
-
Pan T., Lee T.Y., Rietzel E., et al. 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Med Phys 31 (2004) 333-340
-
(2004)
Med Phys
, vol.31
, pp. 333-340
-
-
Pan, T.1
Lee, T.Y.2
Rietzel, E.3
-
4
-
-
2942545968
-
Acquiring 4D thoracic CT scans using a multislice helical method
-
Keall P.J., Starkschall G., Shukla H., et al. Acquiring 4D thoracic CT scans using a multislice helical method. Phys Med Biol 49 (2004) 2053-2067
-
(2004)
Phys Med Biol
, vol.49
, pp. 2053-2067
-
-
Keall, P.J.1
Starkschall, G.2
Shukla, H.3
-
5
-
-
33144484908
-
Automatic re-contouring in 4D radiotherapy
-
Lu W., Olivera G.H., Chen Q., et al. Automatic re-contouring in 4D radiotherapy. Phys Med Biol 51 (2006) 1077-1099
-
(2006)
Phys Med Biol
, vol.51
, pp. 1077-1099
-
-
Lu, W.1
Olivera, G.H.2
Chen, Q.3
-
6
-
-
33748951780
-
Validation of CT-assisted targeting (CAT) software for soft tissue and bony target localization
-
[Abstract]
-
Zhang L., Dong L., Court L., et al. Validation of CT-assisted targeting (CAT) software for soft tissue and bony target localization. [Abstract]. Med Phys 32 Suppl. (2005) 2106
-
(2005)
Med Phys
, vol.32
, Issue.SUPPL
, pp. 2106
-
-
Zhang, L.1
Dong, L.2
Court, L.3
-
7
-
-
0042527165
-
Automated 3-D PDM construction from segmented images using deformable models
-
Kaus M.R., Pekar V., Lorenz C., et al. Automated 3-D PDM construction from segmented images using deformable models. IEEE Trans Med Imaging 22 (2003) 1005-1013
-
(2003)
IEEE Trans Med Imaging
, vol.22
, pp. 1005-1013
-
-
Kaus, M.R.1
Pekar, V.2
Lorenz, C.3
-
8
-
-
4744367365
-
Automated model-based organ delineation for radiotherapy planning in prostatic region
-
Pekar V., McNutt T.R., and Kaus M.R. Automated model-based organ delineation for radiotherapy planning in prostatic region. Int J Radiat Oncol Biol Phys 60 (2004) 973-980
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.60
, pp. 973-980
-
-
Pekar, V.1
McNutt, T.R.2
Kaus, M.R.3
-
9
-
-
34247869928
-
Automatic delineation of on-line head-and-neck computed tomography images: Toward on-line adaptive radiotherapy
-
Zhang T., Chi Y., Meldolesi E., et al. Automatic delineation of on-line head-and-neck computed tomography images: Toward on-line adaptive radiotherapy. Int J Radiat Oncol Biol Phys 68 (2007) 522-530
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.68
, pp. 522-530
-
-
Zhang, T.1
Chi, Y.2
Meldolesi, E.3
-
10
-
-
34247882923
-
Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer
-
Liu H.H., Balter P., Tutt T., et al. Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer. Int J Radiat Oncol Biol Phys 68 (2007) 531-540
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.68
, pp. 531-540
-
-
Liu, H.H.1
Balter, P.2
Tutt, T.3
-
11
-
-
0037249948
-
Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer
-
Erridge S.C., Seppenwoolde Y., Muller S.H., et al. Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer. Radiother Oncol 66 (2003) 75-85
-
(2003)
Radiother Oncol
, vol.66
, pp. 75-85
-
-
Erridge, S.C.1
Seppenwoolde, Y.2
Muller, S.H.3
-
12
-
-
33644760441
-
A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy
-
Jin J.Y., Ajlouni M., Chen Q., et al. A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy. Radiother Oncol 78 (2006) 177-184
-
(2006)
Radiother Oncol
, vol.78
, pp. 177-184
-
-
Jin, J.Y.1
Ajlouni, M.2
Chen, Q.3
-
13
-
-
33845232182
-
Comparison of helical, maximum intensity projection (MIP), and averaged intensity (AI) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer
-
Bradley J.D., Nofal A.N., El Naqa I.M., et al. Comparison of helical, maximum intensity projection (MIP), and averaged intensity (AI) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer. Radiother Oncol 81 (2006) 264-268
-
(2006)
Radiother Oncol
, vol.81
, pp. 264-268
-
-
Bradley, J.D.1
Nofal, A.N.2
El Naqa, I.M.3
-
14
-
-
26944441695
-
Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer
-
Underberg R.W., Lagerwaard F.J., Slotman B.J., et al. Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer. Int J Radiat Oncol Biol Phys 63 (2005) 253-260
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.63
, pp. 253-260
-
-
Underberg, R.W.1
Lagerwaard, F.J.2
Slotman, B.J.3
-
15
-
-
16344366951
-
Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion
-
Rietzel E., Chen G.T., Choi N.C., et al. Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. Int J Radiat Oncol Biol Phys 61 (2005) 1535-1550
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.61
, pp. 1535-1550
-
-
Rietzel, E.1
Chen, G.T.2
Choi, N.C.3
|