메뉴 건너뛰기




Volumn 71, Issue 1 SUPPL., 2008, Pages

Siemens Multileaf Collimator Characterization and Quality Assurance Approaches for Intensity-Modulated Radiotherapy

Author keywords

Automation; Multileaf collimator; Quality assurance; Radiotherapy (conformal); Radiotherapy (intensity modulated)

Indexed keywords

DOSIMETRY; LIGHT MODULATION; MEDICAL IMAGING; OPTICAL COLLIMATORS; QUALITY ASSURANCE;

EID: 41749086918     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2007.07.2394     Document Type: Article
Times cited : (17)

References (9)
  • 1
    • 0033001376 scopus 로고    scopus 로고
    • Technology assessment of multileaf collimation: A North American users survey
    • Klein E.E., Tepper J., Sontag M., et al. Technology assessment of multileaf collimation: A North American users survey. Int J Radiat Oncol Biol Phys 44 (1999) 705-710
    • (1999) Int J Radiat Oncol Biol Phys , vol.44 , pp. 705-710
    • Klein, E.E.1    Tepper, J.2    Sontag, M.3
  • 2
    • 0031690712 scopus 로고    scopus 로고
    • Beam characteristics of a retrofitted double-focused multileaf collimator
    • Das I.J., Desobry G.E., McNeeley S.W., et al. Beam characteristics of a retrofitted double-focused multileaf collimator. Med Phys 25 (1998) 1676-1684
    • (1998) Med Phys , vol.25 , pp. 1676-1684
    • Das, I.J.1    Desobry, G.E.2    McNeeley, S.W.3
  • 3
    • 33645519258 scopus 로고    scopus 로고
    • Assessment of a new multileaf collimator concept using GEANT4 Monte Carlo simulations
    • Tacke M.B., Szymanowski H., Oelfke U., et al. Assessment of a new multileaf collimator concept using GEANT4 Monte Carlo simulations. Med Phys 33 (2006) 1125-1132
    • (2006) Med Phys , vol.33 , pp. 1125-1132
    • Tacke, M.B.1    Szymanowski, H.2    Oelfke, U.3
  • 4
    • 0037150915 scopus 로고    scopus 로고
    • Dosimetric characterization of a new miniature multileaf collimator
    • Hartmann G.H., and Fohlisch F. Dosimetric characterization of a new miniature multileaf collimator. Phys Med Biol 47 (2002) N171-N177
    • (2002) Phys Med Biol , vol.47
    • Hartmann, G.H.1    Fohlisch, F.2
  • 5
    • 0141855366 scopus 로고    scopus 로고
    • MLC dosimetric characteristics for small field and IMRT applications
    • Bayouth J.E., and Morrill S.M. MLC dosimetric characteristics for small field and IMRT applications. Med Phys 30 (2003) 2545-2552
    • (2003) Med Phys , vol.30 , pp. 2545-2552
    • Bayouth, J.E.1    Morrill, S.M.2
  • 6
    • 0038587417 scopus 로고    scopus 로고
    • MLC quality assurance techniques for IMRT applications
    • Bayouth J.E., Wendt D., and Morrill S.M. MLC quality assurance techniques for IMRT applications. Med Phys 30 (2003) 743-750
    • (2003) Med Phys , vol.30 , pp. 743-750
    • Bayouth, J.E.1    Wendt, D.2    Morrill, S.M.3
  • 8
    • 33646620369 scopus 로고    scopus 로고
    • Experience with an IMRT head and neck QA phantom
    • Nelson A., Balter P., Hanson W., et al. Experience with an IMRT head and neck QA phantom. Med Phys 29 (2002) 1366
    • (2002) Med Phys , vol.29 , pp. 1366
    • Nelson, A.1    Balter, P.2    Hanson, W.3
  • 9
    • 4644253384 scopus 로고    scopus 로고
    • Output ratio in air for MLC shaped irregular fields
    • Zhu T.C., Bjarngard B.E., Xiao Y., et al. Output ratio in air for MLC shaped irregular fields. Med Phys 31 (2004) 2480-2490
    • (2004) Med Phys , vol.31 , pp. 2480-2490
    • Zhu, T.C.1    Bjarngard, B.E.2    Xiao, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.