메뉴 건너뛰기




Volumn 40, Issue 7, 2008, Pages 1135-1144

Simulation and mock-up tests of the thermal performance of curtain walls

Author keywords

Curtain walls; Insulation efficiency; Moisture condensation; THERM simulation; Thermal cycling test

Indexed keywords

COMPUTER SIMULATION; CORRELATION METHODS; MOCKUPS; MOISTURE CONTROL; TALL BUILDINGS; THERMAL CYCLING; WALLS (STRUCTURAL PARTITIONS);

EID: 41749085279     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2007.10.004     Document Type: Article
Times cited : (17)

References (17)
  • 1
    • 84969165342 scopus 로고    scopus 로고
    • Analysis of the thermal performance of curtain walls in high-rise residential buildings
    • No S.T., and Kim K.S. Analysis of the thermal performance of curtain walls in high-rise residential buildings. Journal of Asian Architecture and Building Engineering 4 2 (2005) 525-532
    • (2005) Journal of Asian Architecture and Building Engineering , vol.4 , Issue.2 , pp. 525-532
    • No, S.T.1    Kim, K.S.2
  • 2
    • 0029233764 scopus 로고
    • Thermal evaluation of several configurations of insulation and structural materials for some metal stud walls
    • Kosny J., and Christian J.E. Thermal evaluation of several configurations of insulation and structural materials for some metal stud walls. Energy and Buildings 22 (1995) 157-163
    • (1995) Energy and Buildings , vol.22 , pp. 157-163
    • Kosny, J.1    Christian, J.E.2
  • 3
    • 0344513312 scopus 로고    scopus 로고
    • Experimental investigation of cold draft induced by two different types of glazing panels in metal curtain walls
    • Ge H., and Fazio P. Experimental investigation of cold draft induced by two different types of glazing panels in metal curtain walls. Building and Environment 39 (2004) 115-125
    • (2004) Building and Environment , vol.39 , pp. 115-125
    • Ge, H.1    Fazio, P.2
  • 4
    • 4944232300 scopus 로고    scopus 로고
    • Energy-efficient envelope design for high-rise apartments
    • Cheung C.K., Fuller R.J., and Luther M.B. Energy-efficient envelope design for high-rise apartments. Energy and Buildings 37 (2005) 37-48
    • (2005) Energy and Buildings , vol.37 , pp. 37-48
    • Cheung, C.K.1    Fuller, R.J.2    Luther, M.B.3
  • 5
    • 0035571393 scopus 로고    scopus 로고
    • Rating the condensation potential of windows: Results from testing and simulation
    • CI-5-3
    • Carpenter S., and Hanan M. Rating the condensation potential of windows: Results from testing and simulation. ASHRAE Transactions 2001 107 Pt. 2 (2001) CI-5-3
    • (2001) ASHRAE Transactions 2001 , vol.107 , Issue.PART 2
    • Carpenter, S.1    Hanan, M.2
  • 6
    • 18544410886 scopus 로고    scopus 로고
    • THERM simulations of window indoor surface temperatures for predicting condensation
    • CH-03-10-1
    • Kohler C., Arasteh D., and Mitchell R. THERM simulations of window indoor surface temperatures for predicting condensation. ASHRAE Transactions 2003 109 Pt. 1 (2003) CH-03-10-1
    • (2003) ASHRAE Transactions 2003 , vol.109 , Issue.PART 1
    • Kohler, C.1    Arasteh, D.2    Mitchell, R.3
  • 7
    • 20344380708 scopus 로고    scopus 로고
    • Effect of boundary conditions on the prediction of temperature distribution for curtain walls
    • Ge H., and Fazio P. Effect of boundary conditions on the prediction of temperature distribution for curtain walls. ASHRAE Transactions: Research (2004) 249-257
    • (2004) ASHRAE Transactions: Research , pp. 249-257
    • Ge, H.1    Fazio, P.2
  • 8
    • 41749110176 scopus 로고    scopus 로고
    • National Fenestration Rating Council, INC., NFRC 100-2004 Procedure for Determining Fenestration Products U-Factors, NFRC, 2004.
    • National Fenestration Rating Council, INC., NFRC 100-2004 Procedure for Determining Fenestration Products U-Factors, NFRC, 2004.
  • 9
    • 0031619795 scopus 로고    scopus 로고
    • Improving computer simulations of heat transfer for projecting fenestration products: using radiation view-factor models
    • SF-98-3-3
    • Griffith B., Curcija D., Turler D., and Arasteh D. Improving computer simulations of heat transfer for projecting fenestration products: using radiation view-factor models. ASHRAE Transactions 1998 104 Pt. 1 (1998) SF-98-3-3
    • (1998) ASHRAE Transactions 1998 , vol.104 , Issue.PART 1
    • Griffith, B.1    Curcija, D.2    Turler, D.3    Arasteh, D.4
  • 10
    • 41749120008 scopus 로고    scopus 로고
    • American Architectural Manufacturers Association, Windows and sliding glass doors, AAMA, 1998.
    • American Architectural Manufacturers Association, Windows and sliding glass doors, AAMA, 1998.
  • 11
    • 41749108547 scopus 로고    scopus 로고
    • American Society for Testing and Materials, Annual book of ASTM standards Building Constructions (I) E 72 - E 1670, ASTM, 2004.
    • American Society for Testing and Materials, Annual book of ASTM standards Building Constructions (I) E 72 - E 1670, ASTM, 2004.
  • 12
    • 41749111910 scopus 로고    scopus 로고
    • American Architectural Manufacturers Association, Test Method for Thermal Cycling of Exterior Walls: AAMA 501.5-98, AAMA, 1998.
    • American Architectural Manufacturers Association, Test Method for Thermal Cycling of Exterior Walls: AAMA 501.5-98, AAMA, 1998.
  • 13
    • 41749110826 scopus 로고    scopus 로고
    • Lawrence Berkeley National Laboratory, THERM5/WINDOW5 NFRC Simulation manual, LBNL, 2003.
    • Lawrence Berkeley National Laboratory, THERM5/WINDOW5 NFRC Simulation manual, LBNL, 2003.
  • 14
    • 41749085668 scopus 로고    scopus 로고
    • American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., ASHRAE HANDBOOK, 36.3, ASHRAE, 1993.
    • American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., ASHRAE HANDBOOK, 36.3, ASHRAE, 1993.
  • 15
    • 41749106817 scopus 로고    scopus 로고
    • A study on the prevention of surface condensation on lightweight curtain wall structure
    • Kim J.H., Lee K.N., Yeo M.S., and Kim K.W. A study on the prevention of surface condensation on lightweight curtain wall structure. Proceedings of AIK 24 1 (2004) 685-688
    • (2004) Proceedings of AIK , vol.24 , Issue.1 , pp. 685-688
    • Kim, J.H.1    Lee, K.N.2    Yeo, M.S.3    Kim, K.W.4
  • 16
    • 41749100748 scopus 로고    scopus 로고
    • National Institute of Standards and Technology, NIST ITS-90 Thermocouple Database, http://srdata.nist.gov/its90/main/, 2001.
    • National Institute of Standards and Technology, NIST ITS-90 Thermocouple Database, http://srdata.nist.gov/its90/main/, 2001.
  • 17
    • 41749088817 scopus 로고    scopus 로고
    • FLIR systems, ThermaCAMTMS45 technical specifications, FLIR systems, INC., 2004.
    • FLIR systems, ThermaCAMTMS45 technical specifications, FLIR systems, INC., 2004.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.