메뉴 건너뛰기




Volumn 18, Issue 4, 2008, Pages 266-268

High efficiency RF power amplifier designed with harmonic real-time active load-pull

Author keywords

Large signal network analyzer (LSNA); Power added efficiency (PAE); Power amplifier (PA); Real time active load pull (RT ALP)

Indexed keywords

HARMONIC ANALYSIS; OPTIMAL CONTROL SYSTEMS; REAL TIME SYSTEMS;

EID: 41649106737     PISSN: 15311309     EISSN: None     Source Type: Journal    
DOI: 10.1109/LMWC.2008.918913     Document Type: Article
Times cited : (15)

References (8)
  • 2
    • 0031270549 scopus 로고    scopus 로고
    • Class-F power amplifiers with maximally flat waveforms
    • Nov
    • F. H. Raab, "Class-F power amplifiers with maximally flat waveforms," IEEE Trans. Microw. Theory Tech., vol. 45, no. 11, pp. 2007-2012, Nov. 1997.
    • (1997) IEEE Trans. Microw. Theory Tech , vol.45 , Issue.11 , pp. 2007-2012
    • Raab, F.H.1
  • 3
    • 33644755710 scopus 로고    scopus 로고
    • High-efficiency class F RF/microwave power amplifiers
    • Feb
    • S. Gao, "High-efficiency class F RF/microwave power amplifiers," IEEE Microw. Mag., vol. 7, pp. 40-48, Feb. 2006.
    • (2006) IEEE Microw. Mag , vol.7 , pp. 40-48
    • Gao, S.1
  • 5
    • 0020091250 scopus 로고
    • Active load technique for loadpull characterization at microwave frequencies
    • Feb
    • G. P. Bava, U. Pisani, and V. Pozzolo, "Active load technique for loadpull characterization at microwave frequencies," Electron. Lett., vol. 18, pp. 178-180, Feb. 1982.
    • (1982) Electron. Lett , vol.18 , pp. 178-180
    • Bava, G.P.1    Pisani, U.2    Pozzolo, V.3
  • 6
    • 0033365514 scopus 로고    scopus 로고
    • Measurement and control of current/voltage waveforms of microwave transistors using a harmonic load-pull system for the optimum, design of high efficiency power amplifiers
    • Aug
    • D. Barataud, F. Blache, A. Mallet, P. P. Bouysse, J. Nebus, J. P. Villotte, J. Obregon, J. Verspecht, and P. Auxemery, "Measurement and control of current/voltage waveforms of microwave transistors using a harmonic load-pull system for the optimum, design of high efficiency power amplifiers," IEEE Trans. Instrum. Meas., vol. 48, no. 4, pp. 835-842, Aug. 1999.
    • (1999) IEEE Trans. Instrum. Meas , vol.48 , Issue.4 , pp. 835-842
    • Barataud, D.1    Blache, F.2    Mallet, A.3    Bouysse, P.P.4    Nebus, J.5    Villotte, J.P.6    Obregon, J.7    Verspecht, J.8    Auxemery, P.9
  • 7
    • 18744409871 scopus 로고    scopus 로고
    • Real-time and optimal PA characterization speeds up PA design
    • Amsterdam, The Netherlands
    • F. Verbeyst and M. V. Bossche, "Real-time and optimal PA characterization speeds up PA design," in Proc. 34th Eur. Microw. Conf, Amsterdam, The Netherlands, 2004, pp. 431-434.
    • (2004) Proc. 34th Eur. Microw. Conf , pp. 431-434
    • Verbeyst, F.1    Bossche, M.V.2
  • 8
    • 34748925446 scopus 로고    scopus 로고
    • Real-time active load-pull of the 2nd & 3rd harmonics for interactive design of non-linear power amplifiers
    • Dec
    • X. Cui, S. J. Doo, P. Roblin, G. H. Jessen, R. G. Rojas, and J. Strahler, "Real-time active load-pull of the 2nd & 3rd harmonics for interactive design of non-linear power amplifiers," in Proc. 68th ARFTG, Dec. 2006, pp. 42-49.
    • (2006) Proc. 68th ARFTG , pp. 42-49
    • Cui, X.1    Doo, S.J.2    Roblin, P.3    Jessen, G.H.4    Rojas, R.G.5    Strahler, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.