메뉴 건너뛰기




Volumn 57, Issue 4, 2008, Pages 690-698

0.5-μm CMOS implementation of analog heart-rate extraction with a robust peak detector

Author keywords

Analog signal processing (ASP); CMOS; Electrocardiogram (ECG); Heart rate (HR); HR variability (HRV); System on chip

Indexed keywords

DOPPLER RADAR; ELECTROCARDIOGRAPHY; REAL TIME SYSTEMS; SIGNAL FILTERING AND PREDICTION;

EID: 41549143112     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2007.911629     Document Type: Article
Times cited : (23)

References (17)
  • 1
    • 0029919459 scopus 로고    scopus 로고
    • Persons with chronic conditions: Their prevalence and costs
    • Nov. 13
    • C. Hoffman, D. Rice, and H. Sung, "Persons with chronic conditions: Their prevalence and costs," J. Amer. Med. Assoc., vol. 276, no. 18, pp. 1473-1479, Nov. 13, 1996.
    • (1996) J. Amer. Med. Assoc , vol.276 , Issue.18 , pp. 1473-1479
    • Hoffman, C.1    Rice, D.2    Sung, H.3
  • 3
    • 0029928495 scopus 로고    scopus 로고
    • Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology, Heart rate variability: Standards of measurement, physiological interpretation and clinical use, Circulation, 93, no. 5, pp. 1043-1065, Mar. 1996
    • Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology, "Heart rate variability: Standards of measurement, physiological interpretation and clinical use," Circulation, vol. 93, no. 5, pp. 1043-1065, Mar. 1996.
  • 4
    • 0033402841 scopus 로고    scopus 로고
    • Evaluation of frequency and time-frequency spectral analysis of heart rate variability as a diagnostic marker of the sleep apnea syndrome
    • Nov
    • M. F. Hilton, R. A. Bates, K. R. Godfrey, et al., "Evaluation of frequency and time-frequency spectral analysis of heart rate variability as a diagnostic marker of the sleep apnea syndrome," Med. Biol. Eng. Comput., vol. 37, no. 6, pp. 760-769, Nov. 1999.
    • (1999) Med. Biol. Eng. Comput , vol.37 , Issue.6 , pp. 760-769
    • Hilton, M.F.1    Bates, R.A.2    Godfrey, K.R.3
  • 5
    • 13144284940 scopus 로고    scopus 로고
    • Real time electrocardiogram QRS detection using combined adaptive threshold
    • www.biomedical-engineering-online.com/content/3/l/28#B10, Online, Available
    • I. I. Christov, "Real time electrocardiogram QRS detection using combined adaptive threshold," Biomed. Eng. Online, vol. 3, no. 1, p. 28, 2004. [Online]. Available: http:// www.biomedical-engineering-online.com/content/3/l/28#B10
    • (2004) Biomed. Eng. Online , vol.3 , Issue.1 , pp. 28
    • Christov, I.I.1
  • 6
    • 0038274521 scopus 로고    scopus 로고
    • Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnea
    • Jun
    • P. de Chazal, C. Henegham, E. Sheridan, R. Reilly, P. Nolan, and M. O'Malley, "Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnea," IEEE Trans. Biomed. Eng., vol. 50, no. 6, pp. 686-696, Jun. 2003.
    • (2003) IEEE Trans. Biomed. Eng , vol.50 , Issue.6 , pp. 686-696
    • de Chazal, P.1    Henegham, C.2    Sheridan, E.3    Reilly, R.4    Nolan, P.5    O'Malley, M.6
  • 7
    • 0031106763 scopus 로고    scopus 로고
    • A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV
    • Mar
    • A. Ruha, S. Sallinen, and S. Nissilä, "A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV," IEEE Trans. Biomed. Eng., vol. 44, no. 3, pp. 159-167, Mar. 1997.
    • (1997) IEEE Trans. Biomed. Eng , vol.44 , Issue.3 , pp. 159-167
    • Ruha, A.1    Sallinen, S.2    Nissilä, S.3
  • 8
  • 9
    • 29344445678 scopus 로고    scopus 로고
    • A 1-V analog CMOS front-end for detecting QRS complexes in a cardiac signal
    • Dec
    • K. Lasanen and J. Kostamovaara, "A 1-V analog CMOS front-end for detecting QRS complexes in a cardiac signal," IEEE Trans. Circuits Syst. I, Reg. Papers, vol. 52, no. 12, pp. 2584-2594, Dec. 2005.
    • (2005) IEEE Trans. Circuits Syst. I, Reg. Papers , vol.52 , Issue.12 , pp. 2584-2594
    • Lasanen, K.1    Kostamovaara, J.2
  • 10
    • 1942542472 scopus 로고    scopus 로고
    • A fully integrated neural recording amplifier with dc input stabilization
    • May
    • P. Mohseni and K. Najafi, "A fully integrated neural recording amplifier with dc input stabilization," IEEE Trans. Biomed. Eng., vol. 51, no. 5, pp. 832-837, May 2004.
    • (2004) IEEE Trans. Biomed. Eng , vol.51 , Issue.5 , pp. 832-837
    • Mohseni, P.1    Najafi, K.2
  • 11
    • 11144319909 scopus 로고    scopus 로고
    • A web-based vital sign telemonitor and recorder for telemedicine applications
    • P. Mendoza et al., "A web-based vital sign telemonitor and recorder for telemedicine applications," in Proc. IEEE EMBS Int. Conf., 2004, pp. 2196-2199.
    • (2004) Proc. IEEE EMBS Int. Conf , pp. 2196-2199
    • Mendoza, P.1
  • 14
    • 0016564097 scopus 로고
    • Non-invasive microwave measurement of respiration
    • Oct
    • J. C. Lin, "Non-invasive microwave measurement of respiration," Proc. IEEE, vol. 63, no. 10, p. 1530, Oct. 1975.
    • (1975) Proc. IEEE , vol.63 , Issue.10 , pp. 1530
    • Lin, J.C.1
  • 15
    • 0018331344 scopus 로고
    • Microwave apexcardiography
    • Jun
    • J. C. Lin, "Microwave apexcardiography," IEEE Trans. Microw. Theory Tech., vol. MTT-27, no. 6, pp. 618-620, Jun. 1979.
    • (1979) IEEE Trans. Microw. Theory Tech , vol.MTT-27 , Issue.6 , pp. 618-620
    • Lin, J.C.1
  • 16
    • 33846400414 scopus 로고    scopus 로고
    • Single-channel receiver limitations in Doppler radar measurements of periodic motion
    • San Diego, CA, Jan
    • B. K. Park, S. Yamada, O. Boric-Lubecke, and V. M. Lubecke, "Single-channel receiver limitations in Doppler radar measurements of periodic motion," in Proc. IEEE RWS, San Diego, CA, Jan. 2006, pp. 99-102.
    • (2006) Proc. IEEE RWS , pp. 99-102
    • Park, B.K.1    Yamada, S.2    Boric-Lubecke, O.3    Lubecke, V.M.4
  • 17
    • 28544448155 scopus 로고    scopus 로고
    • Heart rate variability: Comparison among devices with different temporal resolutions
    • Dec
    • P. J. Chellakumar, A. Brumfield, K. Kunderu, and A. W. Schopper, "Heart rate variability: Comparison among devices with different temporal resolutions," Physiol. Meas., vol. 26, no. 6, pp. 979-986, Dec. 2005.
    • (2005) Physiol. Meas , vol.26 , Issue.6 , pp. 979-986
    • Chellakumar, P.J.1    Brumfield, A.2    Kunderu, K.3    Schopper, A.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.