메뉴 건너뛰기




Volumn 8, Issue 3, 2008, Pages 1575-1584

Low-cost sensors based on the GMI effect in recycled transformer cores

Author keywords

Giant magnetoimpedance; Sensor; Silicon steel; Transformer core

Indexed keywords

ELECTRIC IMPEDANCE; RECYCLING; SENSORS; SILICON;

EID: 41549126757     PISSN: 14243210     EISSN: 14248220     Source Type: Journal    
DOI: 10.3390/s8031575     Document Type: Article
Times cited : (11)

References (17)
  • 1
    • 33646310341 scopus 로고
    • Giant magnetic field dependent impedance of amorphous FeCoSiB wire
    • Beach, R. S.; Berkowitz, A. E. Giant magnetic field dependent impedance of amorphous FeCoSiB wire. Appl. Phys. Lett. 1994, 64, 3652-3654.
    • (1994) Appl. Phys. Lett , vol.64 , pp. 3652-3654
    • Beach, R.S.1    Berkowitz, A.E.2
  • 2
    • 20644454099 scopus 로고
    • Magnetoimpedance effect in amorphous wires
    • Panina, L. V.; Mohri, K. Magnetoimpedance effect in amorphous wires. Appl. Phys. Lett. 1994, 65, 1189-1191.
    • (1994) Appl. Phys. Lett , vol.65 , pp. 1189-1191
    • Panina, L.V.1    Mohri, K.2
  • 3
    • 34547423263 scopus 로고    scopus 로고
    • Giant magnetoimpedance of electrodeposited Co/Cu/Co on Ag wires
    • Sirisathitkul, C.; Jantaratana, P. Giant magnetoimpedance of electrodeposited Co/Cu/Co on Ag wires. J. Phys. D: Appl. Phys. 2007, 40, 4431-4435.
    • (2007) J. Phys. D: Appl. Phys , vol.40 , pp. 4431-4435
    • Sirisathitkul, C.1    Jantaratana, P.2
  • 4
    • 29244484440 scopus 로고    scopus 로고
    • Dependence of frequency and amplitude of the ac current on the GMI properties of Co based amorphous wires
    • Pal, S. K.; Manik, N. B.; Mitra, A. Dependence of frequency and amplitude of the ac current on the GMI properties of Co based amorphous wires. Mater. Sci. Eng. A 2006, 415, 195-201.
    • (2006) Mater. Sci. Eng. A , vol.415 , pp. 195-201
    • Pal, S.K.1    Manik, N.B.2    Mitra, A.3
  • 5
    • 33646253185 scopus 로고    scopus 로고
    • Effect of annealing temperature on permeability and giant magneto-impedance of Fe-based amorphous ribbon
    • Phan, M. H.; Peng, H. X.; Wisnom, M. R.; Yu, S. C.; Kim, C. G.; Nghi, N. H. Effect of annealing temperature on permeability and giant magneto-impedance of Fe-based amorphous ribbon. Sens. Actual A 2006, 129, 62-65.
    • (2006) Sens. Actual A , vol.129 , pp. 62-65
    • Phan, M.H.1    Peng, H.X.2    Wisnom, M.R.3    Yu, S.C.4    Kim, C.G.5    Nghi, N.H.6
  • 7
    • 33847421742 scopus 로고    scopus 로고
    • Surface modified amorphous ribbon based magnetoimpedance biosensor
    • Kurlyandskaya, G. V.; Miyar V. F. Surface modified amorphous ribbon based magnetoimpedance biosensor. Biosens. Bioelectron. 2007, 22, 2341-2345.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 2341-2345
    • Kurlyandskaya, G.V.1    Miyar, V.F.2
  • 8
    • 33947190419 scopus 로고    scopus 로고
    • Microwire array for giant magneto-impedance detection of magnetic particles for biosensor prototype
    • Chiriac, H.; Herea, D. D.; Corodeanu, S. Microwire array for giant magneto-impedance detection of magnetic particles for biosensor prototype. J. Magn. Magn. Mater. 2007, 311, 425-428.
    • (2007) J. Magn. Magn. Mater , vol.311 , pp. 425-428
    • Chiriac, H.1    Herea, D.D.2    Corodeanu, S.3
  • 9
    • 34249330680 scopus 로고    scopus 로고
    • Current sensor utilizing giant magneto-impedance effect in amorphous ribbon toroidal core and CMOS inverter multivibrator
    • Zhao, Z.; Li, Y. M.; Cheng, J.; Xu, Y. F. Current sensor utilizing giant magneto-impedance effect in amorphous ribbon toroidal core and CMOS inverter multivibrator. Sens. Actual A 2007, 137, 64-67.
    • (2007) Sens. Actual A , vol.137 , pp. 64-67
    • Zhao, Z.1    Li, Y.M.2    Cheng, J.3    Xu, Y.F.4
  • 10
    • 34248562530 scopus 로고    scopus 로고
    • Highly sensitive giant magneto impedance sensor with LC pick-up circuit
    • Kollu, P.; Kim, C.; Yoon, S. S.; Kim, C. O. Highly sensitive giant magneto impedance sensor with LC pick-up circuit. Sens. Lett. 2007, 5, 157-161.
    • (2007) Sens. Lett , vol.5 , pp. 157-161
    • Kollu, P.1    Kim, C.2    Yoon, S.S.3    Kim, C.O.4
  • 13
    • 15044347225 scopus 로고    scopus 로고
    • Yabukami, S.; Mawatari, H.; Horikoshi, N.; Murayama, Y.; Ozawa, T.; Ishiyama, K; Arai, K. I. A design of highly sensitive GMI sensor. J. Magn. Magn. Mater. 2005, 290-291, 1318-1321.
    • Yabukami, S.; Mawatari, H.; Horikoshi, N.; Murayama, Y.; Ozawa, T.; Ishiyama, K; Arai, K. I. A design of highly sensitive GMI sensor. J. Magn. Magn. Mater. 2005, 290-291, 1318-1321.
  • 14
    • 33749131960 scopus 로고    scopus 로고
    • New 1D-2D magnetic sensors for applied electromagnetic engineering
    • Alves, F.; Bensalah, A. D. New 1D-2D magnetic sensors for applied electromagnetic engineering. J. Mater. Proc. Tech. 2007, 181, 194-198.
    • (2007) J. Mater. Proc. Tech , vol.181 , pp. 194-198
    • Alves, F.1    Bensalah, A.D.2
  • 15
    • 0036701120 scopus 로고    scopus 로고
    • Development of amorphous wire type MI sensors for automobile use
    • Honkura, Y. Development of amorphous wire type MI sensors for automobile use. J. Magn. Magn. Mater. 2002, 249, 375-381.
    • (2002) J. Magn. Magn. Mater , vol.249 , pp. 375-381
    • Honkura, Y.1
  • 16
    • 34249330680 scopus 로고    scopus 로고
    • Current sensor utilizing giant magneto-impedance effect in amorphous ribbon toroidal core and CMOS inverter multivibrator
    • Zhan, Z.; Yaoming, L.; Jin, C.; Yunfeng, X. Current sensor utilizing giant magneto-impedance effect in amorphous ribbon toroidal core and CMOS inverter multivibrator. Sens. Actuat. A 2007, 137, 64-67.
    • (2007) Sens. Actuat. A , vol.137 , pp. 64-67
    • Zhan, Z.1    Yaoming, L.2    Jin, C.3    Yunfeng, X.4
  • 17
    • 84876645757 scopus 로고    scopus 로고
    • Nesteruk, K.; Kuzminski, M.; Lachowicz, H. K. Novel magnetic field meter based on giant magneto-impedance (GMI) effect. Sens. Trans. Mag. 2006, 65, 515-520.
    • Nesteruk, K.; Kuzminski, M.; Lachowicz, H. K. Novel magnetic field meter based on giant magneto-impedance (GMI) effect. Sens. Trans. Mag. 2006, 65, 515-520.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.