메뉴 건너뛰기




Volumn 4, Issue 3, 2008, Pages 569-576

Novel sphene coatings on Ti-6Al-4V for orthopedic implants using sol-gel method

Author keywords

Orthopedic; Sphene; Surface chemistry modification; Titanium alloy

Indexed keywords

ADHESION; ALUMINUM ALLOYS; ALUMINUM COATINGS; BOND STRENGTH (MATERIALS); CERAMIC COATINGS; CERAMIC MATERIALS; CHEMICAL STABILITY; CHLORINE COMPOUNDS; DIFFERENTIAL THERMAL ANALYSIS; HYDROXYAPATITE; PHOSPHATE MINERALS; SCANNING ELECTRON MICROSCOPY; SOL-GEL PROCESS; SOL-GELS; SURFACE CHEMISTRY; SURFACE ROUGHNESS; TERNARY ALLOYS; TITANIUM ALLOYS;

EID: 41549122753     PISSN: 17427061     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.actbio.2007.11.005     Document Type: Article
Times cited : (97)

References (32)
  • 1
    • 0032104453 scopus 로고    scopus 로고
    • Corrosion resistance, mechanical properties, corrosion fatigue strength and cytocompatibility of new Ti alloys without Al and V
    • Okazaki Y., Rao S., Ito Y., and Tateishi T. Corrosion resistance, mechanical properties, corrosion fatigue strength and cytocompatibility of new Ti alloys without Al and V. Biomaterials 19 13 (1998) 1197-1215
    • (1998) Biomaterials , vol.19 , Issue.13 , pp. 1197-1215
    • Okazaki, Y.1    Rao, S.2    Ito, Y.3    Tateishi, T.4
  • 2
    • 2942613210 scopus 로고    scopus 로고
    • Comparison of metal release from various metallic biomaterials in vitro
    • Okazaki Y., and Gotoh E. Comparison of metal release from various metallic biomaterials in vitro. Biomaterials 26 1 (2005) 11-21
    • (2005) Biomaterials , vol.26 , Issue.1 , pp. 11-21
    • Okazaki, Y.1    Gotoh, E.2
  • 3
    • 33746794619 scopus 로고    scopus 로고
    • Initial responses of human osteoblasts to sol-gel modified titanium with hydroxyapatite and titania composition
    • Harle J., Kim H.W., Mordan N., Knowles J.C., and Salih V. Initial responses of human osteoblasts to sol-gel modified titanium with hydroxyapatite and titania composition. Acta Biomater 2 5 (2006) 547-556
    • (2006) Acta Biomater , vol.2 , Issue.5 , pp. 547-556
    • Harle, J.1    Kim, H.W.2    Mordan, N.3    Knowles, J.C.4    Salih, V.5
  • 4
    • 34548539020 scopus 로고    scopus 로고
    • Tribological behavior of plasma-sprayed carbon nanotube-reinforced hydroxyapatite coating in physiological solution
    • Balani K., Chen Y., Harimkar S.P., Dahotre N.B., and Agarwal A. Tribological behavior of plasma-sprayed carbon nanotube-reinforced hydroxyapatite coating in physiological solution. Acta Biomater 3 6 (2007) 944-951
    • (2007) Acta Biomater , vol.3 , Issue.6 , pp. 944-951
    • Balani, K.1    Chen, Y.2    Harimkar, S.P.3    Dahotre, N.B.4    Agarwal, A.5
  • 5
    • 11144334095 scopus 로고    scopus 로고
    • In vivo evaluation of plasma-sprayed wollastonite coating
    • Xue W., Liu X., Zheng X., and Ding C. In vivo evaluation of plasma-sprayed wollastonite coating. Biomaterials 26 17 (2005) 3455-3460
    • (2005) Biomaterials , vol.26 , Issue.17 , pp. 3455-3460
    • Xue, W.1    Liu, X.2    Zheng, X.3    Ding, C.4
  • 6
    • 0034980052 scopus 로고    scopus 로고
    • Apatite formed on the surface of plasma-sprayed wollastonite coating immersed in simulated body fluid
    • Liu X., Ding C., and Wang Z. Apatite formed on the surface of plasma-sprayed wollastonite coating immersed in simulated body fluid. Biomaterials 22 14 (2001) 2007-2012
    • (2001) Biomaterials , vol.22 , Issue.14 , pp. 2007-2012
    • Liu, X.1    Ding, C.2    Wang, Z.3
  • 7
    • 0036132299 scopus 로고    scopus 로고
    • An in vitro investigation of plasma sprayed hydroxyapatite (HA) coatings produced with flame-spheroidized feedstock
    • Kweh S.W., Khor K.A., and Cheang P. An in vitro investigation of plasma sprayed hydroxyapatite (HA) coatings produced with flame-spheroidized feedstock. Biomaterials 23 3 (2002) 775-785
    • (2002) Biomaterials , vol.23 , Issue.3 , pp. 775-785
    • Kweh, S.W.1    Khor, K.A.2    Cheang, P.3
  • 8
    • 12344298672 scopus 로고    scopus 로고
    • Surface modification of titanium, titanium alloys, and related materials for biomedical application
    • Liu X., Chu P., and Ding C.X. Surface modification of titanium, titanium alloys, and related materials for biomedical application. Mater Sci Eng R 47 (2004) 49-121
    • (2004) Mater Sci Eng R , vol.47 , pp. 49-121
    • Liu, X.1    Chu, P.2    Ding, C.X.3
  • 9
    • 0026352034 scopus 로고
    • Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy
    • Bauer T.W., Geesink R.C., Zimmerman R., and McMahon J.T. Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy. J Bone Joint Surg Am 73 10 (1991) 1439-1452
    • (1991) J Bone Joint Surg Am , vol.73 , Issue.10 , pp. 1439-1452
    • Bauer, T.W.1    Geesink, R.C.2    Zimmerman, R.3    McMahon, J.T.4
  • 10
    • 0035988671 scopus 로고    scopus 로고
    • 2 composite coatings on titanium alloys
    • 2 composite coatings on titanium alloys. Biomaterials 23 20 (2002) 4065-4077
    • (2002) Biomaterials , vol.23 , Issue.20 , pp. 4065-4077
    • Liu, X.1    Ding, C.2
  • 12
    • 0038046285 scopus 로고    scopus 로고
    • Plasma-sprayed wollastonite 2 M/ZrO2 composite coating
    • Liu X., and Ding C. Plasma-sprayed wollastonite 2 M/ZrO2 composite coating. Surf Coat Tech 172 2-3 (2003) 270-278
    • (2003) Surf Coat Tech , vol.172 , Issue.2-3 , pp. 270-278
    • Liu, X.1    Ding, C.2
  • 13
    • 41549091534 scopus 로고    scopus 로고
    • Wu C, Ramaswamy Y, Soeparto A, Zreiqat H. Incorporation of titanium into calcium silicate improved their chemical stability and biological properties. J Biomed Mater Res A, in press.
    • Wu C, Ramaswamy Y, Soeparto A, Zreiqat H. Incorporation of titanium into calcium silicate improved their chemical stability and biological properties. J Biomed Mater Res A, in press.
  • 14
    • 23744492356 scopus 로고    scopus 로고
    • Improvement of hydroxyapatite sol-gel coating on titanium with ammonium hydroxide addition
    • Kim H.W., and Kim H.E. Improvement of hydroxyapatite sol-gel coating on titanium with ammonium hydroxide addition. J Am Ceram Soc 88 1 (2005) 154-159
    • (2005) J Am Ceram Soc , vol.88 , Issue.1 , pp. 154-159
    • Kim, H.W.1    Kim, H.E.2
  • 15
    • 4644325188 scopus 로고    scopus 로고
    • Hydroxyapatite and fluor-hydroxyapatite layered film on titanium processed by a sol-gel route for hard-tissue implants
    • Kim H.W., Knowles J.C., Salih V., and Kim H.E. Hydroxyapatite and fluor-hydroxyapatite layered film on titanium processed by a sol-gel route for hard-tissue implants. J Biomed Mater Res B Appl Biomater 71 1 (2004) 66-76
    • (2004) J Biomed Mater Res B Appl Biomater , vol.71 , Issue.1 , pp. 66-76
    • Kim, H.W.1    Knowles, J.C.2    Salih, V.3    Kim, H.E.4
  • 16
    • 85121095928 scopus 로고    scopus 로고
    • 3 scaffolds by poly (d, l-lactic acid) modification. Acta Biomater, in press, doi: 10.1016/j.actbio.2007.08.010.
    • 3 scaffolds by poly (d, l-lactic acid) modification. Acta Biomater, in press, doi: 10.1016/j.actbio.2007.08.010.
  • 17
    • 0025418004 scopus 로고
    • Surface chemistry of bioactive glass-ceramics
    • Kokubo T. Surface chemistry of bioactive glass-ceramics. J Non-Cryst Solids 120 (1990) 138-151
    • (1990) J Non-Cryst Solids , vol.120 , pp. 138-151
    • Kokubo, T.1
  • 18
    • 0021690284 scopus 로고
    • Surface-active biomaterials
    • Hench L.L., and Wilson J. Surface-active biomaterials. Science 226 4675 (1984) 630-636
    • (1984) Science , vol.226 , Issue.4675 , pp. 630-636
    • Hench, L.L.1    Wilson, J.2
  • 21
    • 0032403768 scopus 로고    scopus 로고
    • Critical ageing of hydroxyapatite sol-gel solutions
    • Chai C.S., Gross K.A., and Ben-Nissan B. Critical ageing of hydroxyapatite sol-gel solutions. Biomaterials 19 24 (1998) 2291-2296
    • (1998) Biomaterials , vol.19 , Issue.24 , pp. 2291-2296
    • Chai, C.S.1    Gross, K.A.2    Ben-Nissan, B.3
  • 22
    • 4444294267 scopus 로고    scopus 로고
    • A study of hydroxyapatite fibers prepared via sol-gel route
    • Ramanan S.R., and Venkatesh R. A study of hydroxyapatite fibers prepared via sol-gel route. Mater Lett 58 26 (2004) 3320-3323
    • (2004) Mater Lett , vol.58 , Issue.26 , pp. 3320-3323
    • Ramanan, S.R.1    Venkatesh, R.2
  • 23
    • 27744546296 scopus 로고    scopus 로고
    • An overview of the potential of quantitative coating adhesion measurement by scratch testing
    • Bull S.J., and Berasetegui E.G. An overview of the potential of quantitative coating adhesion measurement by scratch testing. Tribol Int 39 2 (2006) 99-114
    • (2006) Tribol Int , vol.39 , Issue.2 , pp. 99-114
    • Bull, S.J.1    Berasetegui, E.G.2
  • 25
    • 34047272508 scopus 로고    scopus 로고
    • Effect of film thickness and interlayer on the adhesion strength of diamond like carbon films on different substrates
    • Wei C., and Yen J.-Y. Effect of film thickness and interlayer on the adhesion strength of diamond like carbon films on different substrates. Diam Relat Mater 16 4-7 (2007) 1325-1330
    • (2007) Diam Relat Mater , vol.16 , Issue.4-7 , pp. 1325-1330
    • Wei, C.1    Yen, J.-Y.2
  • 26
    • 3042694378 scopus 로고    scopus 로고
    • Plasma-sprayed diopside coatings for biomedical applications
    • Xue W., Liu X., Zheng X., and Ding C. Plasma-sprayed diopside coatings for biomedical applications. Surf Coat Tech 185 2-3 (2004) 340-345
    • (2004) Surf Coat Tech , vol.185 , Issue.2-3 , pp. 340-345
    • Xue, W.1    Liu, X.2    Zheng, X.3    Ding, C.4
  • 27
    • 33745684763 scopus 로고    scopus 로고
    • Porous akermanite scaffolds for bone tissue engineering: preparation, characterization, and in vitro studies
    • Wu C., Chang J., Zhai W., Ni S., and Wang J. Porous akermanite scaffolds for bone tissue engineering: preparation, characterization, and in vitro studies. J Biomed Mater Res B Appl Biomater 78 1 (2006) 47-55
    • (2006) J Biomed Mater Res B Appl Biomater , vol.78 , Issue.1 , pp. 47-55
    • Wu, C.1    Chang, J.2    Zhai, W.3    Ni, S.4    Wang, J.5
  • 28
    • 10644235501 scopus 로고    scopus 로고
    • Preparation and characteristics of a calcium magnesium silicate (bredigite) bioactive ceramic
    • Wu C., Chang J., Wang J., Ni S., and Zhai W. Preparation and characteristics of a calcium magnesium silicate (bredigite) bioactive ceramic. Biomaterials 26 16 (2005) 2925-2931
    • (2005) Biomaterials , vol.26 , Issue.16 , pp. 2925-2931
    • Wu, C.1    Chang, J.2    Wang, J.3    Ni, S.4    Zhai, W.5
  • 29
    • 30444437320 scopus 로고    scopus 로고
    • In vitro bioactivity of akermanite ceramics
    • Wu C., Chang J., Ni S., and Wang J. In vitro bioactivity of akermanite ceramics. J Biomed Mater Res A 76 1 (2006) 73-80
    • (2006) J Biomed Mater Res A , vol.76 , Issue.1 , pp. 73-80
    • Wu, C.1    Chang, J.2    Ni, S.3    Wang, J.4
  • 30
    • 33646033125 scopus 로고    scopus 로고
    • 2) films fabricated by cathodic arc deposition
    • 2) films fabricated by cathodic arc deposition. Biomaterials 27 21 (2006) 3904-3911
    • (2006) Biomaterials , vol.27 , Issue.21 , pp. 3904-3911
    • Liu, X.1    Huang, A.2    Ding, C.3    Chu, P.K.4
  • 31
    • 41549141509 scopus 로고    scopus 로고
    • Pecheva E, Petrov T, Lungu C, Montgomery P, Pramatarova L. Stimulated in vitro bone-like apatite formation by a novel laser processing technique. Chem Eng J, in press.
    • Pecheva E, Petrov T, Lungu C, Montgomery P, Pramatarova L. Stimulated in vitro bone-like apatite formation by a novel laser processing technique. Chem Eng J, in press.
  • 32
    • 0032530968 scopus 로고    scopus 로고
    • Size tailoring of magnetite particles formed by aqueous precipitation: an example of thermodynamic stability of nanometric oxide particles
    • Vayssieres L., Chaneac C., Tronc E., and Jolivet J.P. Size tailoring of magnetite particles formed by aqueous precipitation: an example of thermodynamic stability of nanometric oxide particles. J Colloid Interf Sci 205 2 (1998) 205-212
    • (1998) J Colloid Interf Sci , vol.205 , Issue.2 , pp. 205-212
    • Vayssieres, L.1    Chaneac, C.2    Tronc, E.3    Jolivet, J.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.