메뉴 건너뛰기




Volumn 9, Issue 4, 2008, Pages 558-563

A novel dynamic equivalence method for grid-connected wind farm

Author keywords

Dynamic equivalence; Genetic algorithm; Grid connected wind farm; Squirrel Cage Induction Generator (SCIG)

Indexed keywords

ASYNCHRONOUS GENERATORS; COMPUTER SIMULATION; ELECTRIC POWER PLANTS; GENETIC ALGORITHMS; SQUIRREL CAGE MOTORS;

EID: 41549094842     PISSN: 1673565X     EISSN: 18621775     Source Type: Journal    
DOI: 10.1631/jzus.A071564     Document Type: Article
Times cited : (6)

References (13)
  • 1
    • 0016890789 scopus 로고
    • Dynamic single-unit representation of induction motor groups
    • 1
    • Abdel Hakim, M.M., Berg, G.J., 1976. Dynamic single-unit representation of induction motor groups. IEEE Trans. on Power Apparatus and Systems, 95(1):155-166. [doi:10. 1109/T-PAS.1976.32088]
    • (1976) IEEE Trans. on Power Apparatus and Systems , vol.95 , pp. 155-166
    • Abdel Hakim, M.M.1    Berg, G.J.2
  • 3
    • 0034325813 scopus 로고    scopus 로고
    • A third order model for the doubly fed induction machine
    • 2
    • Feijóo, A., Cidrás, J., Carrillo, C., 2000. A third order model for the doubly fed induction machine. Electric Power Research, 56(2):121-127. [doi:10.1016/S0378-7796(00)00103-6]
    • (2000) Electric Power Research , vol.56 , pp. 121-127
    • Feijóo, A.1    Cidrás, J.2    Carrillo, C.3
  • 4
    • 38349050778 scopus 로고    scopus 로고
    • GWEC (Global Wind Energy Council)
    • GWEC (Global Wind Energy Council), 2007. Global Wind 2006 Report. http://www.gwec.net
    • (2007) Global Wind 2006 Report
  • 5
    • 0346034979 scopus 로고    scopus 로고
    • Dynamic modeling of wind farm grid interaction
    • 4
    • Hansen, A.D., Sørensen, P., Blaabjerg, F., Becho, J., 2002. Dynamic modeling of wind farm grid interaction. Wind Engineering, 26(4):191-208. [doi:10.1260/03095240232 1039403]
    • (2002) Wind Engineering , vol.26 , pp. 191-208
    • Hansen, A.D.1    Sørensen, P.2    Blaabjerg, F.3    Becho, J.4
  • 6
    • 84960388103 scopus 로고    scopus 로고
    • A Method for Aggregation of a Group of Induction Motor Loads
    • Kataoka, T., Kai, T., 2000. A Method for Aggregation of a Group of Induction Motor Loads. Int. Conf. on Power System Technology, 3:1683-1688.
    • (2000) Int. Conf. on Power System Technology , vol.3 , pp. 1683-1688
    • Kataoka, T.1    Kai, T.2
  • 10
    • 0023314106 scopus 로고
    • Aggregation of induction motor loads for transient stability studies
    • 1
    • Rahim, A.H.M.A., Laldin, A.R., 1987. Aggregation of induction motor loads for transient stability studies. IEEE Trans. on Energy Conversion, 2(1):55-61.
    • (1987) IEEE Trans. on Energy Conversion , vol.2 , pp. 55-61
    • Rahim, A.H.M.A.1    Laldin, A.R.2
  • 11
    • 0027849334 scopus 로고
    • Reduced transient model of a group of induction motors
    • 4
    • Sriharan, S., Tan, L.H., Ting, H.M., 1993. Reduced transient model of a group of induction motors. IEEE Trans. on Energy Conversion, 8(4):769-777. [doi:10.1109/60.260 993]
    • (1993) IEEE Trans. on Energy Conversion , vol.8 , pp. 769-777
    • Sriharan, S.1    Tan, L.H.2    Ting, H.M.3
  • 13
    • 10944222066 scopus 로고    scopus 로고
    • Analysis on maximum power injection of wind farm connected to power system
    • 2
    • Wu, J.L., Zhou, S.X., Sun, J.F., Chen, S.S., Meng, Q.H., 2004. Analysis on maximum power injection of wind farm connected to power system. Power System Technology, 28(2):28-32 (in Chinese).
    • (2004) Power System Technology , vol.28 , pp. 28-32
    • Wu, J.L.1    Zhou, S.X.2    Sun, J.F.3    Chen, S.S.4    Meng, Q.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.