메뉴 건너뛰기




Volumn 30, Issue 7, 2008, Pages 493-497

No advantages of Gamma nail over sliding hip screw in the management of peritrochanteric hip fractures: A meta-analysis of randomized controlled trials

Author keywords

Internal fixation; Peritrochanteric fractures

Indexed keywords

ARTICLE; BONE NAIL; BONE SCREW; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; FEMUR FRACTURE; FRACTURE FIXATION; HIP FRACTURE; HUMAN; INTERMETHOD COMPARISON; META ANALYSIS; MORTALITY; OPERATION DURATION; PERITROCHANTERIC HIP FRACTURE; POSTOPERATIVE HEMORRHAGE; PRIORITY JOURNAL; PSEUDARTHROSIS; RANDOMIZED CONTROLLED TRIAL; REOPERATION; SYSTEMATIC REVIEW; TREATMENT OUTCOME; WOUND INFECTION;

EID: 41449119277     PISSN: 09638288     EISSN: 14645165     Source Type: Journal    
DOI: 10.1080/09638280701355538     Document Type: Article
Times cited : (25)

References (41)
  • 2
    • 0032059914 scopus 로고    scopus 로고
    • Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the Gamma nail and compression hip screw
    • Madsen, J. E., Naess, L., Aune, A. K., Alho, A., Ekeland, A. and Stromsoe, K. (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the Gamma nail and compression hip screw. J Orthop Trauma, 12, pp. 241-248.
    • (1998) J Orthop Trauma , vol.12 , pp. 241-248
    • Madsen, J.E.1    Naess, L.2    Aune, A.K.3    Alho, A.4    Ekeland, A.5    Stromsoe, K.6
  • 3
    • 0018861236 scopus 로고
    • Mechanics of the treatment of hip injuries
    • Kaufer, H. (1980) Mechanics of the treatment of hip injuries. Clin Orthop Relat Res, 146, pp. 53-61.
    • (1980) Clin Orthop Relat Res , vol.146 , pp. 53-61
    • Kaufer, H.1
  • 4
    • 0020053104 scopus 로고
    • Treatment of intertrochanteric fractures with a sliding nail-plate
    • Bonamo, J. J. and Accettola, A. B. (1982) Treatment of intertrochanteric fractures with a sliding nail-plate. J Trauma, 22, pp. 205-215.
    • (1982) J Trauma , vol.22 , pp. 205-215
    • Bonamo, J.J.1    Accettola, A.B.2
  • 5
    • 0020076988 scopus 로고
    • Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation
    • Wolfgang, G. L., Bryant, M. H. and O'Neill, J. P. (1982) Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation. Clin Orthop Relat Res, 163, pp. 148-158.
    • (1982) Clin Orthop Relat Res , vol.163 , pp. 148-158
    • Wolfgang, G.L.1    Bryant, M.H.2    O'Neill, J.P.3
  • 7
    • 0036512930 scopus 로고    scopus 로고
    • Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: A prospective, randomized study
    • Sadowski, C., Lubbeke, A., Saudan, M., Riand, N., Stern, R. and Hoffmeyer, P. (2002) Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: A prospective, randomized study. J Bone Joint Surg Am, 84, pp. 372-381.
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 372-381
    • Sadowski, C.1    Lubbeke, A.2    Saudan, M.3    Riand, N.4    Stern, R.5    Hoffmeyer, P.6
  • 8
    • 0345451574 scopus 로고    scopus 로고
    • Failure of femoral head fixation: A cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw
    • Haynes, R. C., Poll, R. G., Miles, A. W. and Weston, R. B. (1997) Failure of femoral head fixation: A cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw. Injury, 28, pp. 337-341.
    • (1997) Injury , vol.28 , pp. 337-341
    • Haynes, R.C.1    Poll, R.G.2    Miles, A.W.3    Weston, R.B.4
  • 9
    • 0031866341 scopus 로고    scopus 로고
    • Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw - A randomised prospective trial
    • Park, S. R., Kang, J. S., Kim, H. S., Lee, W. H. and Kim, Y. H. (1998) Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw-a randomised prospective trial. Int Orthop, 22, pp. 157-160.
    • (1998) Int Orthop , vol.22 , pp. 157-160
    • Park, S.R.1    Kang, J.S.2    Kim, H.S.3    Lee, W.H.4    Kim, Y.H.5
  • 10
    • 33645083749 scopus 로고    scopus 로고
    • Misconceptions about the mechanical advantages of intramedullary devices for treatment of proximal femur fractures
    • Zlowodzki, M., Bhandari, M. and Brown, G. A. (2006) Misconceptions about the mechanical advantages of intramedullary devices for treatment of proximal femur fractures. Acta Orthopaedica, 77, pp. 169-170.
    • (2006) Acta Orthopaedica , vol.77 , pp. 169-170
    • Zlowodzki, M.1    Bhandari, M.2    Brown, G.A.3
  • 11
    • 28244449114 scopus 로고    scopus 로고
    • A comparative prospective study of dynamic variable angle hip screw and Gamma nail in intertrochanteric hip fractures
    • Tarantino, U., Oliva, F., Impagliazzo, A., Mattei, A., Cannata, G., Pompili, G. F. and Maffulli, N. (2005) A comparative prospective study of dynamic variable angle hip screw and Gamma nail in intertrochanteric hip fractures. Disabil Rehabil, 27, pp. 1157-1165.
    • (2005) Disabil Rehabil , vol.27 , pp. 1157-1165
    • Tarantino, U.1    Oliva, F.2    Impagliazzo, A.3    Mattei, A.4    Cannata, G.5    Pompili, G.F.6    Maffulli, N.7
  • 12
    • 1342326073 scopus 로고    scopus 로고
    • Intramedullary fixation of pertrochanteric hip fractures with the short AO-ASIF proximal femoral nail
    • Fogagnolo, F., Kfuri Jr, M. and Paccola, C. A. (2004) Intramedullary fixation of pertrochanteric hip fractures with the short AO-ASIF proximal femoral nail. Arch Orthop Trauma Surg, 124, pp. 31-37.
    • (2004) Arch Orthop Trauma Surg , vol.124 , pp. 31-37
    • Fogagnolo, F.1    Kfuri Jr., M.2    Paccola, C.A.3
  • 13
    • 0037326752 scopus 로고    scopus 로고
    • The proximal femoral nail (PFN) - A minimal invasive treatment of unstable proximal femoral fractures: A prospective study of 55 patients with a follow-up of 15 months
    • Boldin, C., Seibert, F. J., Fankhauser, F., Peicha, G., Grechenig, W. and Szyszkowitz, R. (2003) The proximal femoral nail (PFN) - a minimal invasive treatment of unstable proximal femoral fractures: A prospective study of 55 patients with a follow-up of 15 months. Acta Orthop Scand, 74, pp. 53-58.
    • (2003) Acta Orthop Scand , vol.74 , pp. 53-58
    • Boldin, C.1    Seibert, F.J.2    Fankhauser, F.3    Peicha, G.4    Grechenig, W.5    Szyszkowitz, R.6
  • 14
    • 0024422266 scopus 로고
    • Treatment of unstable intertrochanteric and subtrochanteric fractures in elderly patients
    • Haentjens, P., Casteleyn, P. P., De Boeck, H., Handelberg, F. and Opdecam, P. (1989) Treatment of unstable intertrochanteric and subtrochanteric fractures in elderly patients. Primary bipolar arthroplasty compared with internal fixation. J Bone Joint Surg Am, 71, pp. 1214-1225.
    • (1989) J Bone Joint Surg Am , vol.71 , pp. 1214-1225
    • Haentjens, P.1    Casteleyn, P.P.2    De Boeck, H.3    Handelberg, F.4    Opdecam, P.5
  • 15
    • 0026309036 scopus 로고
    • Pertrochanteric fractures in the elderly: Are there indications for primary prosthetic replacement?
    • Broos, P. L., Rommens, P. M., Deleyn, P. R., Geens, V. R. and Stappaerts, K. H. (1991) Pertrochanteric fractures in the elderly: Are there indications for primary prosthetic replacement?. J Orthop Trauma, 5, pp. 446-451.
    • (1991) J Orthop Trauma , vol.5 , pp. 446-451
    • Broos, P.L.1    Rommens, P.M.2    Deleyn, P.R.3    Geens, V.R.4    Stappaerts, K.H.5
  • 16
    • 0035203607 scopus 로고    scopus 로고
    • Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur
    • Adams, C. I., Robinson, C. M., Court-Brown, C. M. and McQueen, M. M. (2001) Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. J Orthop Trauma, 15, pp. 394-400.
    • (2001) J Orthop Trauma , vol.15 , pp. 394-400
    • Adams, C.I.1    Robinson, C.M.2    Court-Brown, C.M.3    McQueen, M.M.4
  • 17
    • 0029616325 scopus 로고
    • Fixation of intertrochanteric hip fractures: Gamma nail versus dynamic hip screw. A randomized, prospective study
    • O'Brien, P. J., Meek, R. N., Blachut, P. A., Broekhuyse, H. M. and Sabharwal, S. (1995) Fixation of intertrochanteric hip fractures: Gamma nail versus dynamic hip screw. A randomized, prospective study. Can J Surg, 38, pp. 516-520.
    • (1995) Can J Surg , vol.38 , pp. 516-520
    • O'Brien, P.J.1    Meek, R.N.2    Blachut, P.A.3    Broekhuyse, H.M.4    Sabharwal, S.5
  • 18
    • 0027170493 scopus 로고
    • A prospective randomised comparison of the dynamic hip screw and the gamma locking nail
    • Radford, P. J., Needoff, M. and Webb, J. K. (1993) A prospective randomised comparison of the dynamic hip screw and the gamma locking nail. J Bone Joint Surg Br, 75, pp. 789-793.
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 789-793
    • Radford, P.J.1    Needoff, M.2    Webb, J.K.3
  • 19
    • 0026504845 scopus 로고
    • Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients
    • Leung, K. S., So, W. S., Shen, W. Y. and Hui, P. W. (1992) Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Joint Surg Br, 74, pp. 345-351.
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 345-351
    • Leung, K.S.1    So, W.S.2    Shen, W.Y.3    Hui, P.W.4
  • 20
    • 0026090325 scopus 로고
    • Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw
    • Bridle, S. H., Patel, A. D., Bircher, M. and Calvert, P. T. (1991) Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw. J Bone Joint Surg Br, 73, pp. 330-334.
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 330-334
    • Bridle, S.H.1    Patel, A.D.2    Bircher, M.3    Calvert, P.T.4
  • 21
    • 33645286249 scopus 로고    scopus 로고
    • Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures
    • Jones, H. W., Johnston, P. and Parker, M. (2006) Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures. Int Orthop, 30, pp. 69-78.
    • (2006) Int Orthop , vol.30 , pp. 69-78
    • Jones, H.W.1    Johnston, P.2    Parker, M.3
  • 22
    • 55049113315 scopus 로고    scopus 로고
    • Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults
    • Parker, M. J. and Handoll, H. H. (2005) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev, p. CD000093.
    • (2005) Cochrane Database Syst Rev
    • Parker, M.J.1    Handoll, H.H.2
  • 23
    • 0026524708 scopus 로고
    • Incorporating variations in the quality of individual randomized trials into meta-analysis
    • Detsky, A. S., Naylor, C. D., O'Rourke, K., McGeer, A. J. and L'Abbe, K. A. (1992) Incorporating variations in the quality of individual randomized trials into meta-analysis. J Clin Epidemiol, 45, pp. 255-265.
    • (1992) J Clin Epidemiol , vol.45 , pp. 255-265
    • Detsky, A.S.1    Naylor, C.D.2    O'Rourke, K.3    McGeer, A.J.4    L'Abbe, K.A.5
  • 24
    • 0030094502 scopus 로고    scopus 로고
    • Intertrochanteric fractures of the femur: A randomized prospective comparision of the Gamma nail and the Ambi hip screw
    • Hoffman, C. W. and Lynskey, T. G. (1996) Intertrochanteric fractures of the femur: A randomized prospective comparision of the Gamma nail and the Ambi hip screw. N Zeal J Surg, 66, pp. 151-155.
    • (1996) N Zeal J Surg , vol.66 , pp. 151-155
    • Hoffman, C.W.1    Lynskey, T.G.2
  • 25
    • 0031434381 scopus 로고    scopus 로고
    • Gamma nail vs Dynamic Hip Screw in 120 patients over 60 years - A randomized trial
    • Kukla, C., Heinz, T., Berger, G., Kwasny, O., Rosenberger, A. and Vecsei, V. (1997) Gamma nail vs Dynamic Hip Screw in 120 patients over 60 years-a randomized trial. Acta Chir Aust, 29, pp. 290-293.
    • (1997) Acta Chir Aust , vol.29 , pp. 290-293
    • Kukla, C.1    Heinz, T.2    Berger, G.3    Kwasny, O.4    Rosenberger, A.5    Vecsei, V.6
  • 26
    • 0031728875 scopus 로고    scopus 로고
    • Compression hip screw and gamma nail for intertrochanteric fractures - Randomized prospective study
    • Kuwabara, H., Wada, T., Minagi, Y., Iwasaki, T. and Tsuji, H. (1998) Compression hip screw and gamma nail for intertrochanteric fractures-Randomized prospective study. Hok J Orthop Trauma, 40, pp. 29-33.
    • (1998) Hok J Orthop Trauma , vol.40 , pp. 29-33
    • Kuwabara, H.1    Wada, T.2    Minagi, Y.3    Iwasaki, T.4    Tsuji, H.5
  • 28
    • 17644364373 scopus 로고    scopus 로고
    • Trochanteric gamma nail and compression hip screw for trochanteric fractures: A randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail
    • Utrilla, A. L., Reig, J. S., Munoz, F. M. and Tufanisco, C. B. (2005) Trochanteric gamma nail and compression hip screw for trochanteric fractures: A randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma, 19, pp. 229-233.
    • (2005) J Orthop Trauma , vol.19 , pp. 229-233
    • Utrilla, A.L.1    Reig, J.S.2    Munoz, F.M.3    Tufanisco, C.B.4
  • 29
    • 41449118714 scopus 로고
    • Comparing the Gamma nail and the Dynamic Hip Screw in the treatment of pertrochanteric fractures
    • Medical Press Limited, London
    • Pahlplatz, P. and Langius, F. (1993) Comparing the Gamma nail and the Dynamic Hip Screw in the treatment of pertrochanteric fractures. Preliminary results of a prospective randomised study, Medical Press Limited, London
    • (1993) Preliminary Results of a Prospective Randomised Study
    • Pahlplatz, P.1    Langius, F.2
  • 31
    • 0028307825 scopus 로고
    • Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients
    • Aune, A. K., Ekeland, A., Odegaard, B., Grogaard, B. and Alho, A. (1994) Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients. Acta Orthop Scand, 65, pp. 127-130.
    • (1994) Acta Orthop Scand , vol.65 , pp. 127-130
    • Aune, A.K.1    Ekeland, A.2    Odegaard, B.3    Grogaard, B.4    Alho, A.5
  • 32
    • 0028866619 scopus 로고
    • Comparison of dynamic hip screw and gamma nail: A prospective, randomized, controlled trial
    • Butt, M. S., Krikler, S. J., Nafie, S. and Ali, M. S. (1995) Comparison of dynamic hip screw and gamma nail: A prospective, randomized, controlled trial. Injury, 26, pp. 615-618.
    • (1995) Injury , vol.26 , pp. 615-618
    • Butt, M.S.1    Krikler, S.J.2    Nafie, S.3    Ali, M.S.4
  • 33
    • 0028528650 scopus 로고
    • A prospective comparative study of the compression hip screw and the gamma nail
    • Goldhagen, P. R., O'Connor, D. R., Schwarze, D. and Schwartz, E. (1994) A prospective comparative study of the compression hip screw and the gamma nail. J Orthop Trauma, 8, pp. 367-372.
    • (1994) J Orthop Trauma , vol.8 , pp. 367-372
    • Goldhagen, P.R.1    O'Connor, D.R.2    Schwarze, D.3    Schwartz, E.4
  • 34
    • 0026506867 scopus 로고
    • The gamma-nail as a resilient alternative to the dynamic hip screw in unstable proximal femoral fractures in the elderly
    • Guyer, P., Landolt, M., Eberle, C. and Keller, H. (1992) The gamma-nail as a resilient alternative to the dynamic hip screw in unstable proximal femoral fractures in the elderly. Helv Chir Acta, 58, pp. 697-703.
    • (1992) Helv Chir Acta , vol.58 , pp. 697-703
    • Guyer, P.1    Landolt, M.2    Eberle, C.3    Keller, H.4
  • 38
    • 0030711655 scopus 로고    scopus 로고
    • Meta-analysis. Potentials and promise
    • Egger, M. and Smith, G. D. (1997) Meta-analysis. Potentials and promise. BMJ, 315, pp. 1371-1374.
    • (1997) BMJ , vol.315 , pp. 1371-1374
    • Egger, M.1    Smith, G.D.2
  • 39
    • 0032558314 scopus 로고    scopus 로고
    • Does quality of reports of randomised trials affect estimates of intervention efficacy reported in meta-analyses?
    • Moher, D., Pham, B., Jones, A., Cook, D. J., Jadad, A. R., Moher, M., Tugwell, P. and Klassen, T. P. (1998) Does quality of reports of randomised trials affect estimates of intervention efficacy reported in meta-analyses?. Lancet, 352, pp. 609-613.
    • (1998) Lancet , vol.352 , pp. 609-613
    • Moher, D.1    Pham, B.2    Jones, A.3    Cook, D.J.4    Jadad, A.R.5    Moher, M.6    Tugwell, P.7    Klassen, T.P.8
  • 40
    • 85047692188 scopus 로고
    • Empirical evidence of bias. Dimensions of methodological quality associated with estimates of treatment effects in controlled trials
    • Schulz, K. F., Chalmers, I., Hayes, R. J. and Altman, D. G. (1995) Empirical evidence of bias. Dimensions of methodological quality associated with estimates of treatment effects in controlled trials. JAMA, 273, pp. 408-412.
    • (1995) JAMA , vol.273 , pp. 408-412
    • Schulz, K.F.1    Chalmers, I.2    Hayes, R.J.3    Altman, D.G.4
  • 41
    • 0029983193 scopus 로고    scopus 로고
    • The importance of quality of primary studies in producing unbiased systematic reviews
    • Khan, K. S., Daya, S. and Jadad, A. (1996) The importance of quality of primary studies in producing unbiased systematic reviews. Arch Intern Med, 156, pp. 661-666.
    • (1996) Arch Intern Med , vol.156 , pp. 661-666
    • Khan, K.S.1    Daya, S.2    Jadad, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.