메뉴 건너뛰기




Volumn 71, Issue 1-2, 2004, Pages 339-343

Investigation of the effect of some irradiation parameters on the response of various types of dosimeters to electron irradiation

Author keywords

Dosimeter films; Electron beams; Irradiation temperature effects; Post irradiation stability

Indexed keywords

ELECTRON IRRADIATION; PARTICLE ACCELERATORS; POLYMERS;

EID: 4143136512     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radphyschem.2004.05.041     Document Type: Conference Paper
Times cited : (14)

References (14)
  • 1
    • 0030130990 scopus 로고    scopus 로고
    • Temperature, Humidity and Time. Combined effects on Radiochromic film dosimeters
    • Abdel-Fattah A., Miller A. Temperature, Humidity and Time. Combined effects on Radiochromic film dosimeters. Radiat. Phys. Chem. 47:1996;611-621
    • (1996) Radiat. Phys. Chem. , vol.47 , pp. 611-621
    • Abdel-Fattah, A.1    Miller, A.2
  • 2
    • 0030199570 scopus 로고    scopus 로고
    • Effect of low irradiation temperature on the gamma ray response of dyed and undyed PMMA dosimeters
    • Biramontri S., Haneda N., Tachibana H., Kojima T. Effect of low irradiation temperature on the gamma ray response of dyed and undyed PMMA dosimeters. Radiat. Phys. Chem. 48:1996;105-109
    • (1996) Radiat. Phys. Chem. , vol.48 , pp. 105-109
    • Biramontri, S.1    Haneda, N.2    Tachibana, H.3    Kojima, T.4
  • 3
    • 4143139398 scopus 로고    scopus 로고
    • Investigation of the effect of temperature, dose rate and short-term post-irradiation change on the response of various types of dosimeters to cobalt-60 gamma radiation for quality assurance in Thailand
    • Vienna.
    • Biramontri, S., 2000. Investigation of the effect of temperature, dose rate and short-term post-irradiation change on the response of various types of dosimeters to cobalt-60 gamma radiation for quality assurance in Thailand. Dosimetry for Radiation Processing IAEA-Tecdoc-1156, Vienna.
    • (2000) Dosimetry for Radiation Processing IAEA-Tecdoc-1156
    • Biramontri, S.1
  • 5
    • 84867265038 scopus 로고    scopus 로고
    • ISO/ASTM Standard 51650-2002, American Society for Testing and Materials, Philadelphia, PA.
    • ISO/ASTM, 2002a. Standard practice for Use of Cellulose Aceteate Dosimetry System, ISO/ASTM Standard 51650-2002, American Society for Testing and Materials, Philadelphia, PA.
    • (2002) Standard Practice for Use of Cellulose Aceteate Dosimetry System
  • 6
    • 84867265038 scopus 로고    scopus 로고
    • ISO/ASTM Standard 51276-2002, American Society for Testing and Materials, Philadelphia, PA.
    • ISO/ASTM, 2002b. Standard practice for Use Polymethylmethacrylate Dosimetry System. ISO/ASTM Standard 51276-2002, American Society for Testing and Materials, Philadelphia, PA.
    • (2002) Standard Practice for Use Polymethylmethacrylate Dosimetry System
  • 7
    • 4143087810 scopus 로고    scopus 로고
    • ISO/ASTM Standard 51275-2002, American Society for Testing and Materials, Philadelphia, PA.
    • ISO/ASTM, 2002c. Standard practice for Use of Radiochromic Film Dosimetry System, ISO/ASTM Standard 51275-2002, American Society for Testing and Materials, Philadelphia, PA.
    • (2002) Standard Practice for Use of Radiochromic Film Dosimetry System
  • 9
    • 0000841926 scopus 로고
    • Temperature and humidity effects on gamma-ray response and stability of plastic and dyed plastic dosimeters
    • Levine H., McLaughlin W.L., Miller A. Temperature and humidity effects on gamma-ray response and stability of plastic and dyed plastic dosimeters. Radiat. Phys. Chem. 14:1979;551-574
    • (1979) Radiat. Phys. Chem. , vol.14 , pp. 551-574
    • Levine, H.1    McLaughlin, W.L.2    Miller, A.3
  • 11
    • 0028806365 scopus 로고
    • Temperature and relative humidity dependence of radiochromic film dosimeter response to gamma and electron radiation
    • McLaughlin W.L., Puhl J.M., Miller A. Temperature and relative humidity dependence of radiochromic film dosimeter response to gamma and electron radiation. Radiat. Phys. Chem. 42:1995;1227-1233
    • (1995) Radiat. Phys. Chem. , vol.42 , pp. 1227-1233
    • McLaughlin, W.L.1    Puhl, J.M.2    Miller, A.3
  • 12
    • 0028454934 scopus 로고
    • Effects of temperature and humidity during irradiation on the response of radiochromic film dosimeters
    • Ningnoi T., Ehlermann D.A.E. Effects of temperature and humidity during irradiation on the response of radiochromic film dosimeters. Radiat. Phys. Chem. 43:1994;569-572
    • (1994) Radiat. Phys. Chem. , vol.43 , pp. 569-572
    • Ningnoi, T.1    Ehlermann, D.A.E.2
  • 13
    • 0021491394 scopus 로고
    • Effects of temperature, relative humidity, and dose rate on the sensitivity of cellulose triacetate dosimeters to electrons and gamma rays
    • Ryuichi T., Shoichi M., Naoyuki T. Effects of temperature, relative humidity, and dose rate on the sensitivity of cellulose triacetate dosimeters to electrons and gamma rays. J. Appl. Radiat. Isot. 35:1984;875-881
    • (1984) J. Appl. Radiat. Isot. , vol.35 , pp. 875-881
    • Ryuichi, T.1    Shoichi, M.2    Naoyuki, T.3
  • 14
    • 0027675753 scopus 로고
    • Temperature response of a number of plastic dosimeters for radiation processing
    • Sohrabpour M., Kazemi A.A., Mousavi H., Solati K. Temperature response of a number of plastic dosimeters for radiation processing. Radiat. Phys. Chem. 42:1993;783-787
    • (1993) Radiat. Phys. Chem. , vol.42 , pp. 783-787
    • Sohrabpour, M.1    Kazemi, A.A.2    Mousavi, H.3    Solati, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.