메뉴 건너뛰기




Volumn 1, Issue , 2003, Pages 348-353

Two-dimensional phase aberration correction using an ultrasonic 1.75D array: Case study on breast microcalcifications

Author keywords

[No Author keywords available]

Indexed keywords

MICROCALCIFICATION; PHASE ABERRATIONS; PHASE SCREENS; ULTRASONIC ARRAYS;

EID: 4143128982     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (14)

References (15)
  • 1
    • 0035498423 scopus 로고    scopus 로고
    • Time-shift estimation and focusing through distributed aberration using multirow arrays
    • J. C. Lacefield and R. C. Waag, "Time-shift estimation and focusing through distributed aberration using multirow arrays," IEEE Trans. Ultrason., Ferroelec., Freq. Contr., vol. 48, no. 6, pp. 1606-1624, 2001.
    • (2001) IEEE Trans. Ultrason., Ferroelec., Freq. Contr. , vol.48 , Issue.6 , pp. 1606-1624
    • Lacefield, J.C.1    Waag, R.C.2
  • 2
    • 0034859106 scopus 로고    scopus 로고
    • Wavefront estimation in the human breast
    • R. C. Gauss, G. Trahey, and M. S. Soo, "Wavefront estimation in the human breast," in Proc. SPIE., vol. 4325, 2001, pp. 172-181.
    • (2001) Proc. SPIE. , vol.4325 , pp. 172-181
    • Gauss, R.C.1    Trahey, G.2    Soo, M.S.3
  • 4
    • 0029342760 scopus 로고
    • Comparison of ultrasonic wavefront distortion and compensation in one-dimensional and two-dimensional apertures
    • D. Liu and R. Waag, "Comparison of ultrasonic wavefront distortion and compensation in one-dimensional and two-dimensional apertures," IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol. 42, no. 4, pp. 726-733, 1995.
    • (1995) IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control , vol.42 , Issue.4 , pp. 726-733
    • Liu, D.1    Waag, R.2
  • 5
    • 0034579358 scopus 로고    scopus 로고
    • Phase aberration correction using near-fi eld redundancy-two-dimensional array algorithm
    • Y. Li and B. Robinson, "Phase aberration correction using near-fi eld redundancy-two-dimensional array algorithm," Ultrasonics Symposium, vol. 2, pp. 1729-1733, 2000.
    • (2000) Ultrasonics Symposium , vol.2 , pp. 1729-1733
    • Li, Y.1    Robinson, B.2
  • 7
    • 0035731027 scopus 로고    scopus 로고
    • Aberration measurement and correction with a high resolution 1.75d array
    • A. T. Fernandez, J. J. Dahl, D. M. Dumont, and G. E. Trahey, "Aberration measurement and correction with a high resolution 1.75d array," Proc. IEEE Ultrason. Symp., vol. 2, pp. 1659-1663, 2001.
    • (2001) Proc. IEEE Ultrason. Symp. , vol.2 , pp. 1659-1663
    • Fernandez, A.T.1    Dahl, J.J.2    Dumont, D.M.3    Trahey, G.E.4
  • 8
    • 84862401001 scopus 로고    scopus 로고
    • Array elevation requirements in phase aberration correction using an 8×128 1.75d array
    • _, "Array elevation requirements in phase aberration correction using an 8×128 1.75d array," SPIE International Symposium on Medical Imaging 2002 Proceedings, vol. 4687, 2002.
    • (2002) SPIE International Symposium on Medical Imaging 2002 Proceedings , vol.4687
  • 10
    • 0033296762 scopus 로고    scopus 로고
    • Adaptive imaging in the thyroid using fundamental and harmonic echo data
    • R. C. Gauss and G. Trahey, "Adaptive imaging in the thyroid using fundamental and harmonic echo data," in Proc. IEEE Ultrason. Symp., vol. 2, 1999, pp. 1515-1519.
    • (1999) Proc. IEEE Ultrason. Symp. , vol.2 , pp. 1515-1519
    • Gauss, R.C.1    Trahey, G.2
  • 12
    • 0027078779 scopus 로고
    • Two-dimensional ultrasonic beam distortion in the breast: In vivo measurements and effects
    • P. D. Freiburger, D. Sullivan, B. H. LeBlanc, S. Smith, and G. Trahey, "Two-dimensional ultrasonic beam distortion in the breast: in vivo measurements and effects," Ultrasonic Imaging, vol. 14, pp. 398-414, 1992.
    • (1992) Ultrasonic Imaging , vol.14 , pp. 398-414
    • Freiburger, P.D.1    Sullivan, D.2    LeBlanc, B.H.3    Smith, S.4    Trahey, G.5
  • 13
    • 0026323672 scopus 로고
    • Measurements of ultrasonic pulse arrival time differences produced by abdominal wall specimens
    • Y. Sumino and R. Waag, "Measurements of ultrasonic pulse arrival time differences produced by abdominal wall specimens." J. Acoustic. Soc. Am., vol. 90, no. 6, pp. 2924-2930, 1991.
    • (1991) J. Acoustic. Soc. Am. , vol.90 , Issue.6 , pp. 2924-2930
    • Sumino, Y.1    Waag, R.2
  • 14
    • 0030968538 scopus 로고    scopus 로고
    • Measurement of ultrasonic pulse distortion produced by human chest wall
    • L. Hinkelman, T. L. Szabo, and R. Waag, "Measurement of ultrasonic pulse distortion produced by human chest wall," J. Acoust. Soc. Am., vol. 101, no. 4, pp. 2365-2373, 1997.
    • (1997) J. Acoust. Soc. Am. , vol.101 , Issue.4 , pp. 2365-2373
    • Hinkelman, L.1    Szabo, T.L.2    Waag, R.3
  • 15
    • 0024111013 scopus 로고
    • Phase aberration correction using signals from point reflectors and diffuse scatters: Basic principles
    • S. Flax and M. O'Donnell, "Phase aberration correction using signals from point reflectors and diffuse scatters: basic principles," IEEE Trans. Ultrason. Ferroelec. Freq. Contr., vol. 35, no, 6, pp. 758-767, 1988.
    • (1988) IEEE Trans. Ultrason. Ferroelec. Freq. Contr. , vol.35 , Issue.6 , pp. 758-767
    • Flax, S.1    O'Donnell, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.