메뉴 건너뛰기




Volumn 16, Issue 8, 2004, Pages 445-446

Novel implication of combined stent crushing and intravascular ultrasound for dislodged stents

Author keywords

[No Author keywords available]

Indexed keywords

EPTIFIBATIDE; FIBRINOGEN RECEPTOR ANTAGONIST; HEPARIN;

EID: 4143124601     PISSN: 10423931     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (12)

References (15)
  • 1
    • 0028916901 scopus 로고
    • Retrieval of occluding unexpanded Pamaz-Schatz stent from a saphenous aorto-coronary vein graft
    • Rozenman Y, Burstein M, Hasin Y, Gotsman MS. Retrieval of occluding unexpanded Pamaz-Schatz stent from a saphenous aorto-coronary vein graft. Cathet Cardiovasc Diagn 1995;34:159-161.
    • (1995) Cathet Cardiovasc Diagn , vol.34 , pp. 159-161
    • Rozenman, Y.1    Burstein, M.2    Hasin, Y.3    Gotsman, M.S.4
  • 2
    • 0027427491 scopus 로고
    • Retrieval of undeployed stents from the right coronary artery: Report of two cases
    • Veldhuijzen F, Bonnier H, Michels H, et al. Retrieval of undeployed stents from the right coronary artery: Report of two cases. Cathet Cardiovasc Diagn 1993;30:245-248.
    • (1993) Cathet Cardiovasc Diagn , vol.30 , pp. 245-248
    • Veldhuijzen, F.1    Bonnier, H.2    Michels, H.3
  • 3
    • 0027426421 scopus 로고
    • Retrieval of a migrated coronary stent by means of an alligator forceps catheter
    • Eeckhout E, Stauffer J, Goy J. Retrieval of a migrated coronary stent by means of an alligator forceps catheter. Cathet Cardiovasc Diagn 1993;30:166-168.
    • (1993) Cathet Cardiovasc Diagn , vol.30 , pp. 166-168
    • Eeckhout, E.1    Stauffer, J.2    Goy, J.3
  • 5
    • 0027467183 scopus 로고
    • Retrieval of a lost coronary stent from descending aorta using a PTCA balloon and biopsy forceps
    • Berder V, Bedossa M, Gras D, et al. Retrieval of a lost coronary stent from descending aorta using a PTCA balloon and biopsy forceps. Cathet Cardiovasc Diagn 1993;28:351-353.
    • (1993) Cathet Cardiovasc Diagn , vol.28 , pp. 351-353
    • Berder, V.1    Bedossa, M.2    Gras, D.3
  • 6
    • 0029825849 scopus 로고    scopus 로고
    • Intracoronary loss of balloon-mounted stents: Successful retrieval with a 2 mm "microsnare" device
    • Elsner M, Pfeifer A, Kasper W. Intracoronary loss of balloon-mounted stents: Successful retrieval with a 2 mm "microsnare" device. Cathet Cardiovasc Diagn 1996;39:271-276.
    • (1996) Cathet Cardiovasc Diagn , vol.39 , pp. 271-276
    • Elsner, M.1    Pfeifer, A.2    Kasper, W.3
  • 7
    • 0032977311 scopus 로고    scopus 로고
    • Dislodged stent: A simple retrieval technique
    • Bogart D, Jung S. Dislodged stent: A simple retrieval technique. Cathet Cardiovasc Diagn 1999;47:323-324.
    • (1999) Cathet Cardiovasc Diagn , vol.47 , pp. 323-324
    • Bogart, D.1    Jung, S.2
  • 8
    • 0034129832 scopus 로고    scopus 로고
    • Facilitation of stent retention and retrieval with an emboli containment device
    • Webb J, Solankhi N, Carere R. Facilitation of stent retention and retrieval with an emboli containment device. Cathet Cardiovasc Diagn 2000;50:215-217.
    • (2000) Cathet Cardiovasc Diagn , vol.50 , pp. 215-217
    • Webb, J.1    Solankhi, N.2    Carere, R.3
  • 9
    • 0032091192 scopus 로고    scopus 로고
    • Surgical removal of a stent entrapped in the left main coronary artery
    • Fukada J, Morishita K, Satou H, et al. Surgical removal of a stent entrapped in the left main coronary artery. Ann Thorac Cardiovasc Surg 1998;4:162-163.
    • (1998) Ann Thorac Cardiovasc Surg , vol.4 , pp. 162-163
    • Fukada, J.1    Morishita, K.2    Satou, H.3
  • 10
    • 0030697464 scopus 로고    scopus 로고
    • Surgical retrieval of undeployed intracoronary stent without cardiopulmonary bypass
    • Gomes WJ, Palma JH, Carvalho AC, Buffalo E. Surgical retrieval of undeployed intracoronary stent without cardiopulmonary bypass. Eur J Cardiothorac Surg 1997;12:666-667.
    • (1997) Eur J Cardiothorac Surg , vol.12 , pp. 666-667
    • Gomes, W.J.1    Palma, J.H.2    Carvalho, A.C.3    Buffalo, E.4
  • 11
    • 0030064191 scopus 로고    scopus 로고
    • Coronary artery endarterectomy for retrieval of entrapped percutaneous angioplasty catheter
    • Rosario PG, Donahoo JS. Coronary artery endarterectomy for retrieval of entrapped percutaneous angioplasty catheter. Ann Thorac Surg 1996;61:218-219.
    • (1996) Ann Thorac Surg , vol.61 , pp. 218-219
    • Rosario, P.G.1    Donahoo, J.S.2
  • 12
    • 0033158425 scopus 로고    scopus 로고
    • Retrieval techniques for dislodged stents
    • Feldman T. Retrieval techniques for dislodged stents. Cathet Cardiovasc Diagn 1999;47:325-326.
    • (1999) Cathet Cardiovasc Diagn , vol.47 , pp. 325-326
    • Feldman, T.1
  • 13
    • 0032463722 scopus 로고    scopus 로고
    • Failed coronary stent deployment
    • Cantor WJ, Lazzam C, Cohen E, et al. Failed coronary stent deployment. Am Heart J 1998;136:1088-1095.
    • (1998) Am Heart J , vol.136 , pp. 1088-1095
    • Cantor, W.J.1    Lazzam, C.2    Cohen, E.3
  • 14
    • 0033104195 scopus 로고    scopus 로고
    • Mechanism, management and outcome of failure of delivery of coronary stents
    • Lohavanichbutr K, Webb J, Carete R, et al. Mechanism, management and outcome of failure of delivery of coronary stents. Am J Cardiol 1999;83:799-781.
    • (1999) Am J Cardiol , vol.83 , pp. 799-781
    • Lohavanichbutr, K.1    Webb, J.2    Carete, R.3
  • 15
    • 0028154107 scopus 로고
    • Evaluating new devices: Acute (in-hospital) results from the new approach to coronary intervention registry
    • Baim DS, Kent KM, King SB III, et al. Evaluating new devices: Acute (in-hospital) results from the new approach to coronary intervention registry. Circulation 1994;89:471-481.
    • (1994) Circulation , vol.89 , pp. 471-481
    • Baim, D.S.1    Kent, K.M.2    King III, S.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.