메뉴 건너뛰기




Volumn 2, Issue , 2003, Pages 1834-1838

A new algorithm for continuous time delay estimation using sampled data

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; DELAY CIRCUITS; JITTER; PARAMETER ESTIMATION; SIGNAL PROCESSING; TISSUE;

EID: 4143109375     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (14)
  • 1
    • 0022692830 scopus 로고
    • Time domain formulation of pulse-doppler ultrasound and blood velocity estimation by cross correlation
    • O. Bonnefous and P. Pesque, "Time domain formulation of pulse-doppler ultrasound and blood velocity estimation by cross correlation," Ultrason. Imaging, vol. 8, pp. 73-85, 1986.
    • (1986) Ultrason. Imaging , vol.8 , pp. 73-85
    • Bonnefous, O.1    Pesque, P.2
  • 2
    • 0024111013 scopus 로고
    • Phase aberration correction using signals from point reflectors and diffuse scatters: Basic principles
    • S. W. Flax and M. O'Donnell, "Phase aberration correction using signals from point reflectors and diffuse scatters: basic principles," IEEE Trans. Ultrason., Ferroelect., Freq. Cont., vol. 35, no. 6, pp. 758-767, 1988.
    • (1988) IEEE Trans. Ultrason., Ferroelect., Freq. Cont. , vol.35 , Issue.6 , pp. 758-767
    • Flax, S.W.1    O'Donnell, M.2
  • 3
    • 0000474501 scopus 로고
    • Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities-part II: Effects of and correction for motion
    • G. E. Trahey and L. F. Nock, "Synthetic Receive Aperture Imaging with Phase Correction for Motion and for Tissue Inhomogeneities-Part II: Effects of and Correction for Motion," IEEE Trans. Ultrason., Ferroelect., Freq. Cont., vol. 39, no. 4, pp. 496-501, 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelect., Freq. Cont. , vol.39 , Issue.4 , pp. 496-501
    • Trahey, G.E.1    Nock, L.F.2
  • 5
    • 0038382246 scopus 로고    scopus 로고
    • Radiation force imaging of viscoelastic properties with reduced artifacts
    • F. Viola and W. F. Walker, "Radiation Force Imaging of Viscoelastic Properties with Reduced Artifacts," IEEE Trans. Ultrason., Ferroelect., Freq. Cont., vol. 50, no. 6, pp. 736-742, 2003.
    • (2003) IEEE Trans. Ultrason., Ferroelect., Freq. Cont. , vol.50 , Issue.6 , pp. 736-742
    • Viola, F.1    Walker, W.F.2
  • 6
    • 0038714256 scopus 로고    scopus 로고
    • A comparison of the performance of time delay estimators in medical ultrasound
    • F. Viola and W. F. Walker, "A Comparison of the Performance of Time Delay Estimators in Medical Ultrasound," IEEE Trans. Ultrason., Ferroelect., Freq. Cont., vol. 50, no. 4, pp. 392-401, 2003.
    • (2003) IEEE Trans. Ultrason., Ferroelect., Freq. Cont. , vol.50 , Issue.4 , pp. 392-401
    • Viola, F.1    Walker, W.F.2
  • 7
    • 0022792026 scopus 로고
    • Comparison of various time delay estimation methods by computer simulation
    • A. Fertner and A. Sjölund, "Comparison of Various Time Delay Estimation Methods by Computer Simulation," IEEE Trans. on Acous., Speech, Signal Proc., vol. 34, pp. 1329-1330, 1986.
    • (1986) IEEE Trans. on Acous., Speech, Signal Proc. , vol.34 , pp. 1329-1330
    • Fertner, A.1    Sjölund, A.2
  • 8
    • 0029462233 scopus 로고
    • Relative performance of two-dimensional speckle-tracking techniques: Normalized correlation, non-normalized correlation, and SAD
    • B. H. Friemel, L. N. Bohs, and G. E. Trahey, "Relative Performance of Two-Dimensional Speckle-Tracking Techniques: Normalized Correlation, Non-Normalized Correlation, and SAD," IEEE Ultrasonic Symposium, pp. 1481-1484, 1995.
    • (1995) IEEE Ultrasonic Symposium , pp. 1481-1484
    • Friemel, B.H.1    Bohs, L.N.2    Trahey, G.E.3
  • 9
    • 0027539558 scopus 로고
    • Discrete time techniques for time delay estimation
    • G. Jacovitti and G. Scarano, "Discrete Time Techniques for Time Delay Estimation," IEEE Trans. Signal Processing, vol. 41, no. 2, pp. 525-533, 1993.
    • (1993) IEEE Trans. Signal Processing , vol.41 , Issue.2 , pp. 525-533
    • Jacovitti, G.1    Scarano, G.2
  • 10
    • 0025908447 scopus 로고
    • Experimental evaluation of the correlation interpolation technique to measure regional tissue velocity
    • P. G. M. de Jong, T. Arts, A. P. G. Hoeks, and R. S. Reneman, "Experimental Evaluation of the Correlation Interpolation Technique to Measure Regional Tissue Velocity," Ultrason. Imaging, vol. 13, pp. 145-161, 1991.
    • (1991) Ultrason. Imaging , vol.13 , pp. 145-161
    • De Jong, P.G.M.1    Arts, T.2    Hoeks, A.P.G.3    Reneman, R.S.4
  • 12
    • 0002999362 scopus 로고    scopus 로고
    • Splines: A perfect fit for signal and image processing
    • M. Unser, "Splines: A Perfect Fit for Signal and Image Processing," IEEE Signal Processing Magazine, vol. 16, no.6, pp. 22-38, 1999.
    • (1999) IEEE Signal Processing Magazine , vol.16 , Issue.6 , pp. 22-38
    • Unser, M.1
  • 13
    • 0029272023 scopus 로고
    • A fundamental limit on delay estimation using partially correlated speckle signals
    • W. F. Walker and G. E. Trahey, "A Fundamental Limit on Delay Estimation Using Partially Correlated Speckle Signals," IEEE Trans. Ultrason., Ferroelect., Freq. Cont., vol. 42, no. 2, pp. 301-308, 1995.
    • (1995) IEEE Trans. Ultrason., Ferroelect., Freq. Cont. , vol.42 , Issue.2 , pp. 301-308
    • Walker, W.F.1    Trahey, G.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.