메뉴 건너뛰기




Volumn 5, Issue 6, 2008, Pages 353-359

Evaluation of the pDR-1200 real-time aerosol monitor

Author keywords

Aspiration efficiency; Light scattering; Nephelometer; PM; Response factor; Transmission efficiency

Indexed keywords

DIESEL FUEL; TOBACCO SMOKE;

EID: 41349118038     PISSN: 15459624     EISSN: 15459632     Source Type: Journal    
DOI: 10.1080/15459620802009919     Document Type: Article
Times cited : (16)

References (11)
  • 2
    • 0034188923 scopus 로고    scopus 로고
    • Aerosol light scattering measurements as a function of relative humidity
    • Day, D., W.C. Malm, and S. Kreidenweis: Aerosol light scattering measurements as a function of relative humidity. J. Air Waste Manage. 5:710-716 (2000).
    • (2000) J. Air Waste Manage , vol.5 , pp. 710-716
    • Day, D.1    Malm, W.C.2    Kreidenweis, S.3
  • 4
    • 0028388852 scopus 로고
    • Correlations between gravimetry and light-scattering photometry for atmospheric aerosols
    • Thomas, A., and J. Gebhart: Correlations between gravimetry and light-scattering photometry for atmospheric aerosols. Atmos. Environ. 28(5):935-938 (1994).
    • (1994) Atmos. Environ , vol.28 , Issue.5 , pp. 935-938
    • Thomas, A.1    Gebhart, J.2
  • 5
    • 2442428310 scopus 로고    scopus 로고
    • Performance evaluation of the active-flow personal DataRAM PM2.5 mass monitor (Thermo Anderson pDR-1200) designed for continuous personal exposure measurements
    • Chakrabarti, B., P.M. Fine, R. Delfino, and C. Sioutas: Performance evaluation of the active-flow personal DataRAM PM2.5 mass monitor (Thermo Anderson pDR-1200) designed for continuous personal exposure measurements. Atmos. Environ. 38(20):3329-3340 (2004).
    • (2004) Atmos. Environ , vol.38 , Issue.20 , pp. 3329-3340
    • Chakrabarti, B.1    Fine, P.M.2    Delfino, R.3    Sioutas, C.4
  • 7
    • 1642430659 scopus 로고    scopus 로고
    • The orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies
    • Paik, S.Y., and J.H. Vincent: The orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies. Ann. Occup. Hyg. 48(1):3-11 (2004).
    • (2004) Ann. Occup. Hyg , vol.48 , Issue.1 , pp. 3-11
    • Paik, S.Y.1    Vincent, J.H.2
  • 8
    • 0032124420 scopus 로고    scopus 로고
    • A survey of wind speeds in indoor workplaces
    • Baldwin, P.E., and A.D. Maynard: A survey of wind speeds in indoor workplaces. Ann. Occup. Hyg. 42(5):303-13 (1998).
    • (1998) Ann. Occup. Hyg , vol.42 , Issue.5 , pp. 303-313
    • Baldwin, P.E.1    Maynard, A.D.2
  • 9
    • 27944479983 scopus 로고    scopus 로고
    • Particle inhalability at low wind speeds
    • Brown, J.: Particle inhalability at low wind speeds. Inhal. Toxicol. 17(14):831-837 (2005).
    • (2005) Inhal. Toxicol , vol.17 , Issue.14 , pp. 831-837
    • Brown, J.1
  • 10
    • 0024610349 scopus 로고
    • A dilution stack sampler for collection of organic aerosol emissions: Design, characterization and field tests
    • Hildemann, L., G.R. Cass, and G.R. Markowski: A dilution stack sampler for collection of organic aerosol emissions: Design, characterization and field tests. Aerosol Sci. Technol. 10:193-204 (1989).
    • (1989) Aerosol Sci. Technol , vol.10 , pp. 193-204
    • Hildemann, L.1    Cass, G.R.2    Markowski, G.R.3
  • 11
    • 41349088525 scopus 로고    scopus 로고
    • National Ambient Air Quality Standards for Particulate Matter, Code of Federal Regulations Title 40, Part 50. 1997
    • "National Ambient Air Quality Standards for Particulate Matter," Code of Federal Regulations Title 40, Part 50. 1997.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.