메뉴 건너뛰기




Volumn 54, Issue 2, 2008, Pages 181-184

Effect of hemolysis and free hemoglobin on optical hematocrit measurements in the extracorporeal circulation

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; CELL CULTURE; DENSITY (OPTICAL); DIALYSIS;

EID: 41349095508     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e318164dcc6     Document Type: Article
Times cited : (7)

References (11)
  • 1
    • 41349083161 scopus 로고    scopus 로고
    • Complications during hemodialysis
    • Nissenson AR, Fine RA eds, New York, McGraw-Hill
    • Sarkar SR, Kaitwatcharachai C, Levin NW: Complications during hemodialysis, in Nissenson AR, Fine RA (eds), Clinical Dialysis. New York, McGraw-Hill, 2005, pp 237-272.
    • (2005) Clinical Dialysis , pp. 237-272
    • Sarkar, S.R.1    Kaitwatcharachai, C.2    Levin, N.W.3
  • 2
    • 24044484898 scopus 로고    scopus 로고
    • Hemodialysis machines and monitors
    • Hörl WH, Koch KM, Lindsay RM, et al eds, Dordrecht/Boston/London, Kluwer Academic Publishers
    • Polaschegg HD, Levin NW: Hemodialysis machines and monitors, in Hörl WH, Koch KM, Lindsay RM, et al (eds), Replacement of Renal Function by Dialysis. Dordrecht/Boston/London, Kluwer Academic Publishers, 2004, pp 325-449.
    • (2004) Replacement of Renal Function by Dialysis , pp. 325-449
    • Polaschegg, H.D.1    Levin, N.W.2
  • 3
    • 34250348323 scopus 로고    scopus 로고
    • Hemolysis: A hidden danger
    • Harman E, Dutka P: Hemolysis: A hidden danger. Nephrol Nurs J 34: 219-220, 223, 2007.
    • (2007) Nephrol Nurs J , vol.34 , Issue.219-220 , pp. 223
    • Harman, E.1    Dutka, P.2
  • 4
    • 41349109153 scopus 로고    scopus 로고
    • Guarding against hidden hemolysis during dialysis: An overview
    • Accessed October 10, 2007
    • Murcutt G, De Vos J-Y, Pilley K, et al: Guarding against hidden hemolysis during dialysis: An overview. EDTNA/ERCA Journal 2007. http://www.edtnaerca.org/pages/journalclub/discussion/summ2007_1.php. Accessed October 10, 2007.
    • (2007) EDTNA/ERCA Journal
    • Murcutt, G.1    De Vos, J.-Y.2    Pilley, K.3
  • 5
    • 0024852107 scopus 로고
    • A sound speed sensor for the measurement of total protein concentration in disposable, blood perfused tubes
    • Schneditz D, Kenner T, Heimel H, Stabinger H: A sound speed sensor for the measurement of total protein concentration in disposable, blood perfused tubes. J Acoust Soc Am 86: 2073-2080, 1989.
    • (1989) J Acoust Soc Am , vol.86 , pp. 2073-2080
    • Schneditz, D.1    Kenner, T.2    Heimel, H.3    Stabinger, H.4
  • 6
    • 0027243873 scopus 로고
    • A new optical technique for monitoring hematocrit and circulating blood volume: Its application in renal dialysis
    • Steuer RR, Harris DH, Conis JM: A new optical technique for monitoring hematocrit and circulating blood volume: Its application in renal dialysis. Dial Transplant 22: 260-265, 1993.
    • (1993) Dial Transplant , vol.22 , pp. 260-265
    • Steuer, R.R.1    Harris, D.H.2    Conis, J.M.3
  • 7
    • 15944398355 scopus 로고    scopus 로고
    • The clinical sequelae of intravascular hemolysis and extracellular plasma hemoglobin: A novel mechanism of human disease
    • Rother RP, Bell L, Hillmen P, Gladwin MT: The clinical sequelae of intravascular hemolysis and extracellular plasma hemoglobin: A novel mechanism of human disease. JAMA 293: 1653-1662, 2005.
    • (2005) JAMA , vol.293 , pp. 1653-1662
    • Rother, R.P.1    Bell, L.2    Hillmen, P.3    Gladwin, M.T.4
  • 8
    • 35148879288 scopus 로고    scopus 로고
    • Relative blood volume measurements during hemodialysis: Comparisons between three noninvasive devices
    • Dasselaar JJ, Huisman RM, De Jong PE, Franssen CFM: Relative blood volume measurements during hemodialysis: Comparisons between three noninvasive devices. Hemodial Int 11: 448-455, 2007.
    • (2007) Hemodial Int , vol.11 , pp. 448-455
    • Dasselaar, J.J.1    Huisman, R.M.2    De Jong, P.E.3    Franssen, C.F.M.4
  • 9
    • 41349097335 scopus 로고    scopus 로고
    • Measurement of indocyanine green (ICG) elimination during extracorporeal liver support (ELS) therapy
    • Schneditz D, Haditsch B, Mekaroonkamol P, Stauber R: Measurement of indocyanine green (ICG) elimination during extracorporeal liver support (ELS) therapy. ASAIO J 51: 61, 2005.
    • (2005) ASAIO J , vol.51 , pp. 61
    • Schneditz, D.1    Haditsch, B.2    Mekaroonkamol, P.3    Stauber, R.4
  • 10
    • 34547688955 scopus 로고    scopus 로고
    • Influence of lipid emulsion for the hematocrit value measured with continuous hematocrit monitor
    • Iwaki H, Okahisa T, Murata M, et al: Influence of lipid emulsion for the hematocrit value measured with continuous hematocrit monitor. ASAIO J 53: 474-478, 2007.
    • (2007) ASAIO J , vol.53 , pp. 474-478
    • Iwaki, H.1    Okahisa, T.2    Murata, M.3
  • 11
    • 0036908599 scopus 로고    scopus 로고
    • Cell-free hemoglobin limits nitric oxide bioavailability in sickle-cell disease
    • Reiter CD, Wang X, Tanus-Santos JE, et al: Cell-free hemoglobin limits nitric oxide bioavailability in sickle-cell disease. Nat Med 8: 1383-1389, 2002.
    • (2002) Nat Med , vol.8 , pp. 1383-1389
    • Reiter, C.D.1    Wang, X.2    Tanus-Santos, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.