메뉴 건너뛰기




Volumn 115, Issue 4, 2008, Pages 673-677

Comparison of Parameters from Heidelberg Retina Tomographs 2 and 3

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; CROSS-SECTIONAL STUDY; FEMALE; GLAUCOMA; GLAUCOMA PROBABILITY SCORE; HEIDELBERG RETINA TOMOGRAPHY; HUMAN; ILLUMINATION; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; OPTIC DISK; OPTIC DISK CUP; OPTIC NERVE; PATIENT SELECTION; PRIORITY JOURNAL; QUALITY CONTROL; SCORING SYSTEM; STEREOMETRY; TOMOGRAPHY;

EID: 41349083381     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ophtha.2007.05.045     Document Type: Article
Times cited : (18)

References (11)
  • 1
    • 0030939485 scopus 로고    scopus 로고
    • Correlation between the visual field indices and Heidelberg retina tomograph parameters
    • Iester M., Mikelberg F.S., Courtright P., and Drance S.M. Correlation between the visual field indices and Heidelberg retina tomograph parameters. J Glaucoma 6 (1997) 78-82
    • (1997) J Glaucoma , vol.6 , pp. 78-82
    • Iester, M.1    Mikelberg, F.S.2    Courtright, P.3    Drance, S.M.4
  • 2
    • 0030783808 scopus 로고    scopus 로고
    • Quantitative estimation of retinal nerve fiber layer height in glaucoma and the relationship with optic nerve head topography and visual field
    • Eid T.M., Spaeth G.L., Katz L.J., et al. Quantitative estimation of retinal nerve fiber layer height in glaucoma and the relationship with optic nerve head topography and visual field. J Glaucoma 6 (1997) 221-230
    • (1997) J Glaucoma , vol.6 , pp. 221-230
    • Eid, T.M.1    Spaeth, G.L.2    Katz, L.J.3
  • 3
    • 0034792898 scopus 로고    scopus 로고
    • Optic disc and visual field changes in a prospective longitudinal study of patients with glaucoma: comparison of scanning laser tomography with conventional perimetry and optic disc photography
    • Chauhan B.C., McCormick T.A., Nicolela M.T., and LeBlanc R.P. Optic disc and visual field changes in a prospective longitudinal study of patients with glaucoma: comparison of scanning laser tomography with conventional perimetry and optic disc photography. Arch Ophthalmol 119 (2001) 1492-1499
    • (2001) Arch Ophthalmol , vol.119 , pp. 1492-1499
    • Chauhan, B.C.1    McCormick, T.A.2    Nicolela, M.T.3    LeBlanc, R.P.4
  • 4
    • 0031770658 scopus 로고    scopus 로고
    • Identification of early glaucoma cases with the scanning laser ophthalmoscope
    • Wollstein G., Garway-Heath D.F., and Hitchings R.A. Identification of early glaucoma cases with the scanning laser ophthalmoscope. Ophthalmology 105 (1998) 1557-1563
    • (1998) Ophthalmology , vol.105 , pp. 1557-1563
    • Wollstein, G.1    Garway-Heath, D.F.2    Hitchings, R.A.3
  • 5
    • 33847213556 scopus 로고    scopus 로고
    • Glaucoma detection with the Heidelberg retina tomograph 3
    • Burgansky-Eliash Z., Wollstein G., Bilonick R.A., et al. Glaucoma detection with the Heidelberg retina tomograph 3. Ophthalmology 114 (2007) 466-471
    • (2007) Ophthalmology , vol.114 , pp. 466-471
    • Burgansky-Eliash, Z.1    Wollstein, G.2    Bilonick, R.A.3
  • 6
    • 0032978904 scopus 로고    scopus 로고
    • Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry
    • Garway-Heath D.F., Poinoosawmy D., Wollstein G., et al. Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry. Br J Ophthalmol 83 (1999) 664-669
    • (1999) Br J Ophthalmol , vol.83 , pp. 664-669
    • Garway-Heath, D.F.1    Poinoosawmy, D.2    Wollstein, G.3
  • 7
    • 0036108625 scopus 로고    scopus 로고
    • Intraobserver and interobserver reproducibility in the evaluation of optic disc stereometric parameters by Heidelberg retina tomograph
    • Miglior S., Albe E., Guareschi M., et al. Intraobserver and interobserver reproducibility in the evaluation of optic disc stereometric parameters by Heidelberg retina tomograph. Ophthalmology 109 (2002) 1072-1077
    • (2002) Ophthalmology , vol.109 , pp. 1072-1077
    • Miglior, S.1    Albe, E.2    Guareschi, M.3
  • 8
    • 0034116776 scopus 로고    scopus 로고
    • Automated analysis of normal and glaucomatous optic nerve head topography images
    • Swindale N.V., Stjepanovic G., Chin A., and Mikelberg F.S. Automated analysis of normal and glaucomatous optic nerve head topography images. Invest Ophthalmol Vis Sci 41 (2000) 1730-1742
    • (2000) Invest Ophthalmol Vis Sci , vol.41 , pp. 1730-1742
    • Swindale, N.V.1    Stjepanovic, G.2    Chin, A.3    Mikelberg, F.S.4
  • 9
    • 33748324384 scopus 로고    scopus 로고
    • R Development Core Team, R Foundation for Statistical Computing, Vienna
    • R Development Core Team. R: A Language and Environment for Statistical Computing (2006), R Foundation for Statistical Computing, Vienna
    • (2006) R: A Language and Environment for Statistical Computing
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.