-
1
-
-
0032716501
-
Clinical validation of intravascular ultrasound imaging for assessment of coronary stenosis severity: comparison with stress myocardial perfusion imaging
-
Nishioka T., Amanullah A.M., Luo H., et al. Clinical validation of intravascular ultrasound imaging for assessment of coronary stenosis severity: comparison with stress myocardial perfusion imaging. J Am Coll Cardiol 33 (1999) 1870-1878
-
(1999)
J Am Coll Cardiol
, vol.33
, pp. 1870-1878
-
-
Nishioka, T.1
Amanullah, A.M.2
Luo, H.3
-
2
-
-
29044445173
-
Relation of myocardial perfusion defects and nonsignificant coronary lesions by angiography with insights from intravascular ultrasound and coronary pressure measurements
-
Rodes-Cabau J., Candell-Riera J., Angel J., et al. Relation of myocardial perfusion defects and nonsignificant coronary lesions by angiography with insights from intravascular ultrasound and coronary pressure measurements. Am J Cardiol 96 (2005) 1621-1626
-
(2005)
Am J Cardiol
, vol.96
, pp. 1621-1626
-
-
Rodes-Cabau, J.1
Candell-Riera, J.2
Angel, J.3
-
3
-
-
34447550465
-
Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis
-
Vanhoenacker P.K., Heijenbrok-Kal M.H., Van Heste R., et al. Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis. Radiology 244 (2007) 419-428
-
(2007)
Radiology
, vol.244
, pp. 419-428
-
-
Vanhoenacker, P.K.1
Heijenbrok-Kal, M.H.2
Van Heste, R.3
-
4
-
-
33845388639
-
Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina
-
Hacker M., Jakobs T., Hack N., et al. Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina. Eur J Nucl Med Mol Imaging 34 (2007) 4-10
-
(2007)
Eur J Nucl Med Mol Imaging
, vol.34
, pp. 4-10
-
-
Hacker, M.1
Jakobs, T.2
Hack, N.3
-
5
-
-
33845329177
-
Relationship between noninvasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging
-
Schuijf J.D., Wijns W., Jukema J.W., et al. Relationship between noninvasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging. J Am Coll Cardiol 48 (2006) 2508-2514
-
(2006)
J Am Coll Cardiol
, vol.48
, pp. 2508-2514
-
-
Schuijf, J.D.1
Wijns, W.2
Jukema, J.W.3
-
6
-
-
33745653354
-
Diagnostic accuracy of 64-slice multislice computed tomography in the noninvasive evaluation of significant coronary artery disease
-
Schuijf J.D., Pundziute G., Jukema J.W., et al. Diagnostic accuracy of 64-slice multislice computed tomography in the noninvasive evaluation of significant coronary artery disease. Am J Cardiol 98 (2006) 145-148
-
(2006)
Am J Cardiol
, vol.98
, pp. 145-148
-
-
Schuijf, J.D.1
Pundziute, G.2
Jukema, J.W.3
-
7
-
-
0016490238
-
A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association
-
Austen W.G., Edwards J.E., Frye R.L., et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51 Suppl 4 (1975) 5-40
-
(1975)
Circulation
, vol.51
, Issue.SUPPL. 4
, pp. 5-40
-
-
Austen, W.G.1
Edwards, J.E.2
Frye, R.L.3
-
8
-
-
11144354420
-
Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound
-
Leber A.W., Knez A., Becker A., et al. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol 43 (2004) 1241-1247
-
(2004)
J Am Coll Cardiol
, vol.43
, pp. 1241-1247
-
-
Leber, A.W.1
Knez, A.2
Becker, A.3
-
9
-
-
0035084861
-
Comparison of left ventricular function at rest and post-stress in patients with myocardial infarction: evaluation with gated SPECT
-
Bavelaar-Croon C.D., America Y.G., Atsma D.E., et al. Comparison of left ventricular function at rest and post-stress in patients with myocardial infarction: evaluation with gated SPECT. J Nucl Cardiol 8 (2001) 10-18
-
(2001)
J Nucl Cardiol
, vol.8
, pp. 10-18
-
-
Bavelaar-Croon, C.D.1
America, Y.G.2
Atsma, D.E.3
-
10
-
-
0037192118
-
Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
-
Cerqueira M.D., Weissman N.J., Dilsizian V., et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105 (2002) 539-542
-
(2002)
Circulation
, vol.105
, pp. 539-542
-
-
Cerqueira, M.D.1
Weissman, N.J.2
Dilsizian, V.3
-
11
-
-
1042287365
-
Stress myocardial perfusion single-photon emission computed tomography is clinically effective and cost effective in risk stratification of patients with a high likelihood of coronary artery disease (CAD) but no known CAD
-
Hachamovitch R., Hayes S.W., Friedman J.D., Cohen I., and Berman D.S. Stress myocardial perfusion single-photon emission computed tomography is clinically effective and cost effective in risk stratification of patients with a high likelihood of coronary artery disease (CAD) but no known CAD. J Am Coll Cardiol 43 (2004) 200-208
-
(2004)
J Am Coll Cardiol
, vol.43
, pp. 200-208
-
-
Hachamovitch, R.1
Hayes, S.W.2
Friedman, J.D.3
Cohen, I.4
Berman, D.S.5
-
12
-
-
0031539281
-
Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging
-
Smanio P.E., Watson D.D., Segalla D.L., Vinson E.L., Smith W.H., and Beller G.A. Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging. J Am Coll Cardiol 30 (1997) 1687-1692
-
(1997)
J Am Coll Cardiol
, vol.30
, pp. 1687-1692
-
-
Smanio, P.E.1
Watson, D.D.2
Segalla, D.L.3
Vinson, E.L.4
Smith, W.H.5
Beller, G.A.6
-
13
-
-
0035863608
-
Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenoses and comparison with fractional flow reserve
-
Briguori C., Anzuini A., Airoldi F., et al. Intravascular ultrasound criteria for the assessment of the functional significance of intermediate coronary artery stenoses and comparison with fractional flow reserve. Am J Cardiol 87 (2001) 136-141
-
(2001)
Am J Cardiol
, vol.87
, pp. 136-141
-
-
Briguori, C.1
Anzuini, A.2
Airoldi, F.3
-
14
-
-
0033587505
-
Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings: importance of lumen dimensions
-
Abizaid A.S., Mintz G.S., Mehran R., et al. Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings: importance of lumen dimensions. Circulation 100 (1999) 256-261
-
(1999)
Circulation
, vol.100
, pp. 256-261
-
-
Abizaid, A.S.1
Mintz, G.S.2
Mehran, R.3
-
15
-
-
4143065864
-
Relationship between stress-induced myocardial ischemia and atherosclerosis measured by coronary calcium tomography
-
Berman D.S., Wong N.D., Gransar H., et al. Relationship between stress-induced myocardial ischemia and atherosclerosis measured by coronary calcium tomography. J Am Coll Cardiol 44 (2004) 923-930
-
(2004)
J Am Coll Cardiol
, vol.44
, pp. 923-930
-
-
Berman, D.S.1
Wong, N.D.2
Gransar, H.3
-
16
-
-
0029073780
-
Atherosclerosis in angiographically "normal" coronary artery reference segments: an intravascular ultrasound study with clinical correlations
-
Mintz G.S., Painter J.A., Pichard A.D., et al. Atherosclerosis in angiographically "normal" coronary artery reference segments: an intravascular ultrasound study with clinical correlations. J Am Coll Cardiol 25 (1995) 1479-1485
-
(1995)
J Am Coll Cardiol
, vol.25
, pp. 1479-1485
-
-
Mintz, G.S.1
Painter, J.A.2
Pichard, A.D.3
|