-
1
-
-
0033360081
-
Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex
-
J. K. Chapin, K. A. Moxon, R. S. Markowitz, and M. A. L. Nicolelis, "Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex," Nature, vol. 2, no. 7, 1999.
-
(1999)
Nature
, vol.2
, Issue.7
-
-
Chapin, J.K.1
Moxon, K.A.2
Markowitz, R.S.3
Nicolelis, M.A.L.4
-
2
-
-
34047166463
-
Online control of a prosthetic arm from motor control signals
-
S. Tillery, D. M. Taylor, and R. Issacs, "Online control of a prosthetic arm from motor control signals," Soc. Neurosci. Abst., vol. 26, 2000.
-
(2000)
Soc. Neurosci. Abst
, vol.26
-
-
Tillery, S.1
Taylor, D.M.2
Issacs, R.3
-
3
-
-
0037075605
-
Brain-machine interface: Instant neural control of a movement signal
-
M. D. Serruya, N. G. Hatsopoulos, L. Paninski, M. R. Fellows, and J. P. Donoghue, "Brain-machine interface: instant neural control of a movement signal," Nature, vol. 416, pp. 141-142, 2002.
-
(2002)
Nature
, vol.416
, pp. 141-142
-
-
Serruya, M.D.1
Hatsopoulos, N.G.2
Paninski, L.3
Fellows, M.R.4
Donoghue, J.P.5
-
4
-
-
0037036102
-
Direct cortical control of 3-D neuroprosthetic devices
-
D. M. Taylor, S. I. Tillery, and A. B. Schwartz, "Direct cortical control of 3-D neuroprosthetic devices," Science, vol. 296, no. 5574, pp. 1829-1832, 2002.
-
(2002)
Science
, vol.296
, Issue.5574
, pp. 1829-1832
-
-
Taylor, D.M.1
Tillery, S.I.2
Schwartz, A.B.3
-
5
-
-
0034785252
-
Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia, a multicenter study
-
Oct
-
P. H. Peckham, M. W. Keith, K. L. Kilgore, J. H. Grill, K. S. Wuolle, G. B. Thrope, P. Gorman, J. Hobby, M. J. Mulcahey, S. Carroll, V. R. Hentz, and A. Wiegner, "Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia, a multicenter study," Arch PM & R, vol. 82, pp. 1380-1388, Oct. 2001.
-
(2001)
Arch PM & R
, vol.82
, pp. 1380-1388
-
-
Peckham, P.H.1
Keith, M.W.2
Kilgore, K.L.3
Grill, J.H.4
Wuolle, K.S.5
Thrope, G.B.6
Gorman, P.7
Hobby, J.8
Mulcahey, M.J.9
Carroll, S.10
Hentz, V.R.11
Wiegner, A.12
-
6
-
-
0026121182
-
A family of neuromuscular stimulators with optical transcutaneous control
-
J. Jarvis and S. Salmons, "A family of neuromuscular stimulators with optical transcutaneous control," J. Med. Eng. Technol., vol. 15, no. 2, pp. 53-57, 1991.
-
(1991)
J. Med. Eng. Technol
, vol.15
, Issue.2
, pp. 53-57
-
-
Jarvis, J.1
Salmons, S.2
-
7
-
-
0025458827
-
A transcutaneous optical information transmisión system for implantable motor-driven artificial hearts
-
Y. Mitamura, E. Okamoto, and M. Tomohisa, "A transcutaneous optical information transmisión system for implantable motor-driven artificial hearts," ASAIO Trans., vol. 36, pp. M278-M280, 1990.
-
(1990)
ASAIO Trans
, vol.36
-
-
Mitamura, Y.1
Okamoto, E.2
Tomohisa, M.3
-
8
-
-
0026866640
-
Transcutaneous optical telemetry system for an implantable electrical ventricular heart assist devive
-
J. A. Miller, G. Belanger, I. Song, and F. Johnson, "Transcutaneous optical telemetry system for an implantable electrical ventricular heart assist devive," Med. Biol. Eng. Comput., vol. 30, pp. 370-372, 1992.
-
(1992)
Med. Biol. Eng. Comput
, vol.30
, pp. 370-372
-
-
Miller, J.A.1
Belanger, G.2
Song, I.3
Johnson, F.4
-
9
-
-
0031807679
-
Transcutaneous optical telemetry system using laser diode
-
K. I. Inoue et al., "Transcutaneous optical telemetry system using laser diode," Japan. J. Artificial Organs, vol. 27, no. 2, pp. 363-367, 1998.
-
(1998)
Japan. J. Artificial Organs
, vol.27
, Issue.2
, pp. 363-367
-
-
Inoue, K.I.1
-
10
-
-
0030907416
-
Implantable volume monitor and miniaturized stimulator dedicated to bladder control
-
M. Sawan, K. Arabi, and B. Provost, "Implantable volume monitor and miniaturized stimulator dedicated to bladder control," Artif. Organs, vol. 21, no. 3, pp. 219-222, 1997.
-
(1997)
Artif. Organs
, vol.21
, Issue.3
, pp. 219-222
-
-
Sawan, M.1
Arabi, K.2
Provost, B.3
-
11
-
-
0024179029
-
Fundamental study on transcutaneous biotelemetry using diffused light
-
N. Kudo, K. Shimizu, and G. Matsumoto, "Fundamental study on transcutaneous biotelemetry using diffused light," Frontiers Med. Biol. Eng., vol. 1, no. 1, pp. 19-28, 1988.
-
(1988)
Frontiers Med. Biol. Eng
, vol.1
, Issue.1
, pp. 19-28
-
-
Kudo, N.1
Shimizu, K.2
Matsumoto, G.3
-
12
-
-
0037109515
-
Transcutaneous photocoupler for transmission of biological signals
-
K. Goto and T. Nakagawa, "Transcutaneous photocoupler for transmission of biological signals," Opt. Lett., vol. 27, no. 20, pp. 1797-1799, 2002.
-
(2002)
Opt. Lett
, vol.27
, Issue.20
, pp. 1797-1799
-
-
Goto, K.1
Nakagawa, T.2
-
13
-
-
34047107289
-
An optical telemetry system for wireless transmission of biomedical signals across the skin,
-
Ph.D. dissertation, Dept. Elect. Eng, Mass. Inst. Technol, Cambridge, MA
-
B. C. Larson, "An optical telemetry system for wireless transmission of biomedical signals across the skin," Ph.D. dissertation, Dept. Elect. Eng., Mass. Inst. Technol., Cambridge, MA, 1999.
-
(1999)
-
-
Larson, B.C.1
-
14
-
-
19944405110
-
Transdermal optical communications
-
J. L. Abita and W. Schneider, "Transdermal optical communications," Johns Hopkins APL Techn. Dig., vol. 25, no. 3, pp. 261-268, 2004.
-
(2004)
Johns Hopkins APL Techn. Dig
, vol.25
, Issue.3
, pp. 261-268
-
-
Abita, J.L.1
Schneider, W.2
-
15
-
-
11144349544
-
Hybrid rf/ir transcutaneous telemetry for power and high-bandwidth data
-
K. S. Guillory, A. K. Misener, and A. Pungor, "Hybrid rf/ir transcutaneous telemetry for power and high-bandwidth data," in Proc. IEEE Eng. Med. Biol. Conf., 2004, pp. 4338-4340.
-
(2004)
Proc. IEEE Eng. Med. Biol. Conf
, pp. 4338-4340
-
-
Guillory, K.S.1
Misener, A.K.2
Pungor, A.3
-
16
-
-
0031711208
-
Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique
-
C. R. Simpson and M. Kohl, "Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique," Phys. Med. Biol., vol. 43, pp. 2465-2478, 1998.
-
(1998)
Phys. Med. Biol
, vol.43
, pp. 2465-2478
-
-
Simpson, C.R.1
Kohl, M.2
-
17
-
-
0035138927
-
Optical properties of porcine skin dermis between 900 nm and 1500 nm
-
Y. Du, X. H. Hu, M. Cariveau, X. Ma, G. W. Kalmus, and J. Q. Lu, "Optical properties of porcine skin dermis between 900 nm and 1500 nm," Phys. Med. Biol., vol. 46, pp. 167-181, 2001.
-
(2001)
Phys. Med. Biol
, vol.46
, pp. 167-181
-
-
Du, Y.1
Hu, X.H.2
Cariveau, M.3
Ma, X.4
Kalmus, G.W.5
Lu, J.Q.6
-
22
-
-
0029045693
-
MCML - Monte carlo modeling of light transport in multi-layered tissues
-
L. Wang, S. L. Jacques, and L. Zheng, "MCML - Monte carlo modeling of light transport in multi-layered tissues," Comput. Methods Programs Biomed., vol. 47, pp. 131-146, 1995.
-
(1995)
Comput. Methods Programs Biomed
, vol.47
, pp. 131-146
-
-
Wang, L.1
Jacques, S.L.2
Zheng, L.3
-
23
-
-
4644238101
-
A biophysically-based spectral model of light interaction with human skin
-
A. Krishnaswamy and G. V. G. Baranoski, "A biophysically-based spectral model of light interaction with human skin," Eurograph., vol. 23, no. 3, pp. 331-340, 2004.
-
(2004)
Eurograph
, vol.23
, Issue.3
, pp. 331-340
-
-
Krishnaswamy, A.1
Baranoski, G.V.G.2
-
24
-
-
0035297583
-
Optical properties of human skin in the near-infrared wavelength range of 1000 to 2200 nm
-
T. L. Troy and S. N. Thennadil, "Optical properties of human skin in the near-infrared wavelength range of 1000 to 2200 nm," J. Biomed. Opt., vol. 6, no. 2, pp. 167-176, 2001.
-
(2001)
J. Biomed. Opt
, vol.6
, Issue.2
, pp. 167-176
-
-
Troy, T.L.1
Thennadil, S.N.2
-
25
-
-
0000286061
-
Spectral transmittance and reflectance of excised human skin
-
J. D. Hardy, H. T. Hammel, and D. Murgatroyd, "Spectral transmittance and reflectance of excised human skin," J. Applied Physiol., vol. 9, no. 2, pp. 257-264, 1956.
-
(1956)
J. Applied Physiol
, vol.9
, Issue.2
, pp. 257-264
-
-
Hardy, J.D.1
Hammel, H.T.2
Murgatroyd, D.3
-
26
-
-
0020673595
-
The quantification of skin transparency
-
I. R. Hastie and P. H. Millard, "The quantification of skin transparency," Brit. J. Dermatol., vol. 108, pp. 315-320, 1983.
-
(1983)
Brit. J. Dermatol
, vol.108
, pp. 315-320
-
-
Hastie, I.R.1
Millard, P.H.2
|