Volumn 55, Issue 4, 2008, Pages 1355-1364

Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments

Author keywords

Dosimetry; Magnetic resonance imaging (MRI); MRI safety

Indexed keywords

COMPUTER SIMULATION; DOSIMETERS; DOSIMETRY; HEALTH CARE; MAGNETIC FIELD EFFECTS; MAGNETIC FIELD MEASUREMENT; MAGNETIC RESONANCE IMAGING; REGULATORY COMPLIANCE; STANDARDS;

EID: 41149128188     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2007.913410     Document Type: Article
Times cited : (69)

References (21)
  • 2
    • 8844231144 scopus 로고    scopus 로고
    • Numerical evaluation of the fields caused by body motion in or near high-field MRI scanners
    • S. Crozier and F. Liu, "Numerical evaluation of the fields caused by body motion in or near high-field MRI scanners," Progress Biophys. Molecular Biol., vol. 87, pp. 267-278, 2005.
    • (2005) Progress Biophys. Molecular Biol , vol.87 , pp. 267-278
    • Crozier, S.1    Liu, F.2
  • 3
    • 12744278243 scopus 로고    scopus 로고
    • Numerical modelling of thermal effects in rats due to high-field magnetic resonance imaging (0.5-1 GHz)
    • A. Trakic, S. Crozier, and F. Liu, "Numerical modelling of thermal effects in rats due to high-field magnetic resonance imaging (0.5-1 GHz)," Phys. Med. Biol., vol. 49, pp. 5547-5558, 2004.
    • (2004) Phys. Med. Biol , vol.49 , pp. 5547-5558
    • Trakic, A.1    Crozier, S.2    Liu, F.3
  • 7
    • 0001243709 scopus 로고    scopus 로고
    • SAFE model - A new method for predicting peripheral nerve stimulation in MRI
    • F. X. Hebrank, "SAFE model - A new method for predicting peripheral nerve stimulation in MRI," Proc. Int. Soc. Mag. Res. Med., vol. 8, p. 2007, 2000.
    • (2000) Proc. Int. Soc. Mag. Res. Med , vol.8 , pp. 2007
    • Hebrank, F.X.1
  • 8
    • 0027225604 scopus 로고
    • Limits to neural stimulation in echoplanar imaging
    • P. Mansfield and P. R. Harvey, "Limits to neural stimulation in echoplanar imaging," Magnetic Res. Med., vol. 29, pp. 746-758, 1993.
    • (1993) Magnetic Res. Med , vol.29 , pp. 746-758
    • Mansfield, P.1    Harvey, P.R.2
  • 9
    • 0033933150 scopus 로고    scopus 로고
    • Review of patient safety in time-varying gradient fields
    • D. J. Schaefer, J. D. Bourland, and J. A. Nyenhuis, "Review of patient safety in time-varying gradient fields," J. Mag. Res. Imag., vol. 12, pp. 20-29, 2000.
    • (2000) J. Mag. Res. Imag , vol.12 , pp. 20-29
    • Schaefer, D.J.1    Bourland, J.D.2    Nyenhuis, J.A.3
  • 11
    • 0343375204 scopus 로고    scopus 로고
    • Guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz)
    • Int. Comm. Non-Ionizing Radiation Protection ICNIRP
    • "Guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz)," Health Phys., vol. 74, pp. 494-522, 1998, Int. Comm. Non-Ionizing Radiation Protection (ICNIRP).
    • (1998) Health Phys , vol.74 , pp. 494-522
  • 12
    • 41149109859 scopus 로고    scopus 로고
    • Directive 2004/40/EC of the european parliament and of the Council, Official J. Eur. Union, L 159, 2004.
    • "Directive 2004/40/EC of the european parliament and of the Council," Official J. Eur. Union, vol. L 159, 2004.
  • 13
    • 41149158373 scopus 로고    scopus 로고
    • A Magnetic Field Dosimeter-PCT/AU2005/001495.
    • A Magnetic Field Dosimeter-PCT/AU2005/001495.
  • 14
    • 0042664135 scopus 로고    scopus 로고
    • On the induced electric field gradients in the human body for magnetic stimulation by gradient coils in MRI
    • Jul
    • H. W. Z. Liu and S. Crozier, "On the induced electric field gradients in the human body for magnetic stimulation by gradient coils in MRI," IEEE Trans. Biomed. Eng., vol. 50, no. 7, pp. 804-815, Jul. 2003.
    • (2003) IEEE Trans. Biomed. Eng , vol.50 , Issue.7 , pp. 804-815
    • Liu, H.W.Z.1    Crozier, S.2
  • 15
    • 41149100851 scopus 로고    scopus 로고
    • Induced fields by body movement and head-shake in high-field MRI
    • L. Feng, H. Zhao, and S. Crozier, "Induced fields by body movement and head-shake in high-field MRI," J. Magn. Reson., vol. 161/1, pp. 99-107, 2003.
    • (2003) J. Magn. Reson , vol.161 , Issue.1 , pp. 99-107
    • Feng, L.1    Zhao, H.2    Crozier, S.3
  • 16
    • 33745976435 scopus 로고    scopus 로고
    • Energetics and mechanics of human walking at oscillating speeds
    • A. E. Minetti et al., "Energetics and mechanics of human walking at oscillating speeds," J. Amer. Zool., vol. 41, pp. 205-210, 2001.
    • (2001) J. Amer. Zool , vol.41 , pp. 205-210
    • Minetti, A.E.1
  • 17
    • 21844473021 scopus 로고    scopus 로고
    • The development and test of a device for the reconstruction of 3-D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers
    • Jul
    • D. Giansanti et al., "The development and test of a device for the reconstruction of 3-D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers," IEEE Trans. Biomed. Eng., vol. 52, no. 7, pp. 1271-1277, Jul. 2005.
    • (2005) IEEE Trans. Biomed. Eng , vol.52 , Issue.7 , pp. 1271-1277
    • Giansanti, D.1
  • 18
    • 0037387514 scopus 로고    scopus 로고
    • Head-trunk coordination during linear anterior-posterior translations
    • E. A. Keshner, "Head-trunk coordination during linear anterior-posterior translations," J. Neurophysiol., vol. 89, pp. 1891-1901, 2003.
    • (2003) J. Neurophysiol , vol.89 , pp. 1891-1901
    • Keshner, E.A.1
  • 19
    • 22144494653 scopus 로고    scopus 로고
    • Coordination of head and trunk accelerations during walking
    • J. J. Kavanagh et al., "Coordination of head and trunk accelerations during walking," Eur. J. Applied Physiol., vol. 94, pp. 468-475, 2005.
    • (2005) Eur. J. Applied Physiol , vol.94 , pp. 468-475
    • Kavanagh, J.J.1
  • 20
    • 41149130982 scopus 로고    scopus 로고
    • Static B0 field monitoring at 3 T and 7 T: An MRI dosimeter proceeding of ISMRM
    • P. M. Glover et al., "Static B0 field monitoring at 3 T and 7 T: An MRI dosimeter proceeding of ISMRM," in Proc. 14th Scientific Meeting, 2006.
    • (2006) Proc. 14th Scientific Meeting
    • Glover, P.M.1
  • 21
    • 35848961010 scopus 로고    scopus 로고
    • Exposure of workers to pulsed gradients in MRI
    • S. Crozier, H. Wang, A. Trakic, and F. Liu, "Exposure of workers to pulsed gradients in MRI," J. Magn. Resonance Imag., vol. 26, pp. 1236-1254, 2007.
    • (2007) J. Magn. Resonance Imag , vol.26 , pp. 1236-1254
    • Crozier, S.1    Wang, H.2    Trakic, A.3    Liu, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.