메뉴 건너뛰기




Volumn 17, Issue 2, 2008, Pages 122-127

Retinal nerve fiber layer thickness in normal, ocular hypertensive, and glaucomatous Indian eyes: An optical coherence tomography study

Author keywords

Glaucoma; Indian eyes; Ocular hypertensive; Optical coherence tomography; Retinal nerve fiber layer thickness

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; ETHNICITY; FEMALE; HUMAN; INDIA; INTRAOCULAR HYPERTENSION; MALE; NERVE FIBER; OPEN ANGLE GLAUCOMA; OPTICAL COHERENCE TOMOGRAPHY; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; RETINA NERVE CELL; VISUAL FIELD;

EID: 40949157510     PISSN: 10570829     EISSN: None     Source Type: Journal    
DOI: 10.1097/IJG.0b013e31814b9817     Document Type: Article
Times cited : (40)

References (24)
  • 1
    • 4644343744 scopus 로고    scopus 로고
    • Risk assessment in the management of patients with ocular hypertension
    • Weinreb R, Freidman S, Fechtner R, et al. Risk assessment in the management of patients with ocular hypertension. Am J Ophthalmol. 2004;138:458-467.
    • (2004) Am J Ophthalmol , vol.138 , pp. 458-467
    • Weinreb, R.1    Freidman, S.2    Fechtner, R.3
  • 2
    • 0026099038 scopus 로고
    • Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss
    • Sommer A, Katz J, Quigley HA, et al. Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. Arch Ophthalmol. 1991;109:77-83.
    • (1991) Arch Ophthalmol , vol.109 , pp. 77-83
    • Sommer, A.1    Katz, J.2    Quigley, H.A.3
  • 3
    • 0033986066 scopus 로고    scopus 로고
    • The retinal nerve fiber layer thickness in ocular hypertensive, normal and glaucomatous eyes with Ocular Coherence Tomography
    • Bowd C, Weinreb RN, Williams JM, et al. The retinal nerve fiber layer thickness in ocular hypertensive, normal and glaucomatous eyes with Ocular Coherence Tomography. Arch Ophthalmol. 2000;118:22-26.
    • (2000) Arch Ophthalmol , vol.118 , pp. 22-26
    • Bowd, C.1    Weinreb, R.N.2    Williams, J.M.3
  • 4
    • 0036138991 scopus 로고    scopus 로고
    • Comparison of optic nerve imaging methods to distinguish normal eyes from glaucoma
    • Greaney MJ, Hoffman DC, Garway-Heath DF, et al. Comparison of optic nerve imaging methods to distinguish normal eyes from glaucoma. Invest Ophthalmol Vis Sci. 2002;43:140-145.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 140-145
    • Greaney, M.J.1    Hoffman, D.C.2    Garway-Heath, D.F.3
  • 5
    • 0029068398 scopus 로고
    • Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography
    • Schuman JS, Hee MR, Puliafito CA, et al. Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. Arch Ophthalmol. 1995;113:586-596.
    • (1995) Arch Ophthalmol , vol.113 , pp. 586-596
    • Schuman, J.S.1    Hee, M.R.2    Puliafito, C.A.3
  • 6
    • 0034943558 scopus 로고    scopus 로고
    • Discriminating between normal and glaucomatous eyes using the Heidelberg Retinal Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph
    • Zangwill LM, Bowd C, Berry CC, et al. Discriminating between normal and glaucomatous eyes using the Heidelberg Retinal Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph. Arch Ophthalmol. 2001;119:985-993.
    • (2001) Arch Ophthalmol , vol.119 , pp. 985-993
    • Zangwill, L.M.1    Bowd, C.2    Berry, C.C.3
  • 7
    • 12244291935 scopus 로고    scopus 로고
    • Quantification of the retinal nerve fiber layer thickness in normal Indian eyes with optical coherence tomography
    • Sony P, Sihota R, Tewari HK, et al. Quantification of the retinal nerve fiber layer thickness in normal Indian eyes with optical coherence tomography. Ind J Ophthalmol. 2004;52:303-309.
    • (2004) Ind J Ophthalmol , vol.52 , pp. 303-309
    • Sony, P.1    Sihota, R.2    Tewari, H.K.3
  • 8
    • 33644845057 scopus 로고    scopus 로고
    • Retinal nerve fiber layer measurements in normal Indian population by optical coherence tomography
    • Ramakrishnan R, Mittal S, Ambatkat S, et al. Retinal nerve fiber layer measurements in normal Indian population by optical coherence tomography. Ind J Ophthalmol. 2006;54:11-15.
    • (2006) Ind J Ophthalmol , vol.54 , pp. 11-15
    • Ramakrishnan, R.1    Mittal, S.2    Ambatkat, S.3
  • 9
    • 14644428939 scopus 로고    scopus 로고
    • Comparison of macular and peripapillary measurements for the detection of glaucoma: An Optical Coherence Tomography Study
    • Leung CKS, Chan W, Yung W, et al. Comparison of macular and peripapillary measurements for the detection of glaucoma: an Optical Coherence Tomography Study. Ophthalmology. 2005;112:391-400.
    • (2005) Ophthalmology , vol.112 , pp. 391-400
    • Leung, C.K.S.1    Chan, W.2    Yung, W.3
  • 10
    • 11844254835 scopus 로고    scopus 로고
    • Comparison of three optical coherence tomography scanning areas for detection of glaucomatous damage
    • Wollstein G, Ishikawa H, Wang J, et al. Comparison of three optical coherence tomography scanning areas for detection of glaucomatous damage. Am J Ophthalmol. 2005;139:39-43.
    • (2005) Am J Ophthalmol , vol.139 , pp. 39-43
    • Wollstein, G.1    Ishikawa, H.2    Wang, J.3
  • 11
    • 11844270529 scopus 로고    scopus 로고
    • Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography
    • Medeiros FA, Zangwill LM, Bowd C, et al. Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol. 2005;139:44-55.
    • (2005) Am J Ophthalmol , vol.139 , pp. 44-55
    • Medeiros, F.A.1    Zangwill, L.M.2    Bowd, C.3
  • 12
    • 2942618989 scopus 로고    scopus 로고
    • Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma
    • Medeiros FA, Zangwill LM, Bowd C, et al. Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma. Arch Ophthalmol. 2004;122:827-837.
    • (2004) Arch Ophthalmol , vol.122 , pp. 827-837
    • Medeiros, F.A.1    Zangwill, L.M.2    Bowd, C.3
  • 13
    • 23244456347 scopus 로고    scopus 로고
    • Reproducibility of retinal nerve fiber thickness measurements using the Stratus OCT in normal and glaucomatous eyes
    • Budenz DL, Chang RT, Huang X, et al. Reproducibility of retinal nerve fiber thickness measurements using the Stratus OCT in normal and glaucomatous eyes. Invest Ophthalmol Vis Sci. 2005;45:2440-2443.
    • (2005) Invest Ophthalmol Vis Sci , vol.45 , pp. 2440-2443
    • Budenz, D.L.1    Chang, R.T.2    Huang, X.3
  • 14
    • 11344261778 scopus 로고    scopus 로고
    • Sensitivity and specificity of the Stratus OCT for perimetric glaucoma
    • Budenz DL, Michael A, Chang RT, et al. Sensitivity and specificity of the Stratus OCT for perimetric glaucoma. Ophthalmology. 2005;112:3-9.
    • (2005) Ophthalmology , vol.112 , pp. 3-9
    • Budenz, D.L.1    Michael, A.2    Chang, R.T.3
  • 15
    • 20144374602 scopus 로고    scopus 로고
    • Comparison of glaucomatous parameters in normal, ocular hypertensive and glaucomatous eyes using optical coherence tomography
    • Choi MG, Han M, Kim YI, et al. Comparison of glaucomatous parameters in normal, ocular hypertensive and glaucomatous eyes using optical coherence tomography. Korean J Ophthalmol. 2005;19:40-46.
    • (2005) Korean J Ophthalmol , vol.19 , pp. 40-46
    • Choi, M.G.1    Han, M.2    Kim, Y.I.3
  • 16
    • 18244389991 scopus 로고    scopus 로고
    • Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments
    • Bourne RR, Mederios FA, Bowd C, et al. Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments. Invest Ophthalmol Vis Sci. 2005;46:1280-1285.
    • (2005) Invest Ophthalmol Vis Sci , vol.46 , pp. 1280-1285
    • Bourne, R.R.1    Mederios, F.A.2    Bowd, C.3
  • 17
    • 25844519567 scopus 로고    scopus 로고
    • Discrimination between normal and glaucomatous eyes using Stratus optical coherence tomography in Taiwan Chinese subjects
    • Chen HY, Huang ML. Discrimination between normal and glaucomatous eyes using Stratus optical coherence tomography in Taiwan Chinese subjects. Graefe's Arch Clin Exp Ophthalmol. 2005;243:894-902.
    • (2005) Graefe's Arch Clin Exp Ophthalmol , vol.243 , pp. 894-902
    • Chen, H.Y.1    Huang, M.L.2
  • 18
    • 33646191940 scopus 로고    scopus 로고
    • Correlation between retinal nerve fiber layer thickness and central corneal thickness in patients with ocular hypertension: An OCT Study
    • Kaushik S, Gyatsho J, Jain R, et al. Correlation between retinal nerve fiber layer thickness and central corneal thickness in patients with ocular hypertension: an OCT Study. Am J Ophthalmol. 2006;141:884-890.
    • (2006) Am J Ophthalmol , vol.141 , pp. 884-890
    • Kaushik, S.1    Gyatsho, J.2    Jain, R.3
  • 19
    • 13444311829 scopus 로고    scopus 로고
    • Relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertensive patients
    • Henderson PA, Medeiros FA, Zangwill LM, et al. Relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertensive patients. Ophthalmology. 2005;112:251-256.
    • (2005) Ophthalmology , vol.112 , pp. 251-256
    • Henderson, P.A.1    Medeiros, F.A.2    Zangwill, L.M.3
  • 20
    • 0037310816 scopus 로고    scopus 로고
    • Corneal thickness measurements and visual field abnormalities in ocular hypertensive patients
    • Medeiros FA, Sample PA, Weinreb RN. Corneal thickness measurements and visual field abnormalities in ocular hypertensive patients. Am J Ophthalmol. 2003;135:131-137.
    • (2003) Am J Ophthalmol , vol.135 , pp. 131-137
    • Medeiros, F.A.1    Sample, P.A.2    Weinreb, R.N.3
  • 21
    • 0141848321 scopus 로고    scopus 로고
    • Corneal thickness measurements and frequency doubling technology perimetry abnormalities in ocular hypertensive eyes
    • Medeiros FA, Sample PA, Weinreb RN. Corneal thickness measurements and frequency doubling technology perimetry abnormalities in ocular hypertensive eyes. Ophthalmology. 2003;110:1903-1908.
    • (2003) Ophthalmology , vol.110 , pp. 1903-1908
    • Medeiros, F.A.1    Sample, P.A.2    Weinreb, R.N.3
  • 22
    • 33645412386 scopus 로고    scopus 로고
    • Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma
    • Medeiros FA, Zangwill LM, Bowd C, et al. Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma. Invest Ophthalmol Vis Sci. 2006;47:1008-1015.
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 1008-1015
    • Medeiros, F.A.1    Zangwill, L.M.2    Bowd, C.3
  • 23
    • 33748957054 scopus 로고    scopus 로고
    • Baseline optical coherence tomography predicts the development of glaucomatous change in glaucoma suspects
    • Lalezary M, Medeiros FA, Weinreb RN, et al. Baseline optical coherence tomography predicts the development of glaucomatous change in glaucoma suspects. Am J Ophthalmol. 2006;142:576-582.
    • (2006) Am J Ophthalmol , vol.142 , pp. 576-582
    • Lalezary, M.1    Medeiros, F.A.2    Weinreb, R.N.3
  • 24
    • 33644673457 scopus 로고    scopus 로고
    • Development and comparison of automated classifiers for glaucoma diagnosis using Stratus optical coherence tomography
    • Huang ML, Chan HY. Development and comparison of automated classifiers for glaucoma diagnosis using Stratus optical coherence tomography. Invest Ophthlamol Vis Sci. 2005;46:4121-4129.
    • (2005) Invest Ophthlamol Vis Sci , vol.46 , pp. 4121-4129
    • Huang, M.L.1    Chan, H.Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.