메뉴 건너뛰기




Volumn 191, Issue 2, 2008, Pages 231-238

Design of a superconducting volume coil for magnetic resonance microscopy of the mouse brain

Author keywords

Finite element radiofrequency model; Helmholtz pair; Microscopy; Mouse brain; Superconducting coil

Indexed keywords

BRAIN; CRYOGENICS; ELECTRIC COILS; MAGNETIC RESONANCE; MICROSCOPIC EXAMINATION; RATS; YTTRIUM BARIUM COPPER OXIDES;

EID: 40949149398     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2007.12.018     Document Type: Article
Times cited : (23)

References (28)
  • 1
    • 16444383528 scopus 로고    scopus 로고
    • Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodents
    • Mai W., Badea C.T., Wheeler C.T., Hedlund L.W., and Johnson G.A. Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodents. Magnetic Resonance in Medicine 53 (2005) 858-865
    • (2005) Magnetic Resonance in Medicine , vol.53 , pp. 858-865
    • Mai, W.1    Badea, C.T.2    Wheeler, C.T.3    Hedlund, L.W.4    Johnson, G.A.5
  • 2
    • 0011525098 scopus 로고
    • Diffusion-limited resolution in nuclear magnetic-resonance microscopy
    • Callaghan P.T., and Eccles C.D. Diffusion-limited resolution in nuclear magnetic-resonance microscopy. Journal of Magnetic Resonance 78 (1988) 1-8
    • (1988) Journal of Magnetic Resonance , vol.78 , pp. 1-8
    • Callaghan, P.T.1    Eccles, C.D.2
  • 3
    • 0023812470 scopus 로고
    • Nuclear magnetic-resonance microscopy with 4-Mu-M resolution-theoretical-study and experimental results
    • Cho Z.H., Ahn C.B., Juh S.C., Lee H.K., Jacobs R.E., Lee S., Yi J.H., and Jo J.M. Nuclear magnetic-resonance microscopy with 4-Mu-M resolution-theoretical-study and experimental results. Medical Physics 15 (1988) 815-824
    • (1988) Medical Physics , vol.15 , pp. 815-824
    • Cho, Z.H.1    Ahn, C.B.2    Juh, S.C.3    Lee, H.K.4    Jacobs, R.E.5    Lee, S.6    Yi, J.H.7    Jo, J.M.8
  • 6
    • 0028763727 scopus 로고
    • Magnetic-resonance microscopy of embryonic-cell lineages and movements
    • Jacobs R.E., and Fraser S.E. Magnetic-resonance microscopy of embryonic-cell lineages and movements. Science 263 (1994) 681-684
    • (1994) Science , vol.263 , pp. 681-684
    • Jacobs, R.E.1    Fraser, S.E.2
  • 9
    • 40949101583 scopus 로고    scopus 로고
    • R. Haueisen, D. Marek, M. Sacher, K. Ugurbil, S. Junge, Flexible cryoprobe-setup for mice brain imaging and spectroscopy at 9.4 T, in: 23rd Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology, Warsaw, Poland, 2006, pp. 78.
    • R. Haueisen, D. Marek, M. Sacher, K. Ugurbil, S. Junge, Flexible cryoprobe-setup for mice brain imaging and spectroscopy at 9.4 T, in: 23rd Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology, Warsaw, Poland, 2006, pp. 78.
  • 10
    • 40949121282 scopus 로고    scopus 로고
    • N. Radzwill, R. Haueisen, D. Marech, M. Sacher, S. Junge, Benefits og cryogenic coils for routine in vivo mouse brain imaging and spectroscopy at 9.4 T, in: I.S.f.M.R.i. Medicine, (Ed.), ISMRM 15th Scientific Meeting and Exhibition, Berlin, Germany, 2007, pp. 627.
    • N. Radzwill, R. Haueisen, D. Marech, M. Sacher, S. Junge, Benefits og cryogenic coils for routine in vivo mouse brain imaging and spectroscopy at 9.4 T, in: I.S.f.M.R.i. Medicine, (Ed.), ISMRM 15th Scientific Meeting and Exhibition, Berlin, Germany, 2007, pp. 627.
  • 15
    • 0032109066 scopus 로고    scopus 로고
    • A superconducting probehead applicable for nuclear magnetic resonance microscopy at 7 T
    • Odoj F., Rommel E., von Kienlin M., and Haase A. A superconducting probehead applicable for nuclear magnetic resonance microscopy at 7 T. Review of Scientific Instruments 69 (1998) 2708-2712
    • (1998) Review of Scientific Instruments , vol.69 , pp. 2708-2712
    • Odoj, F.1    Rommel, E.2    von Kienlin, M.3    Haase, A.4
  • 16
    • 0345528225 scopus 로고    scopus 로고
    • Perspectives with cryogenic RF probes in biomedical MRI
    • Darrasse L., and Ginefri J.C. Perspectives with cryogenic RF probes in biomedical MRI. Biochimie 85 (2003) 915-937
    • (2003) Biochimie , vol.85 , pp. 915-937
    • Darrasse, L.1    Ginefri, J.C.2
  • 17
    • 0027559913 scopus 로고    scopus 로고
    • R.S. Withers, G.C. Liang, B.F. Cole, M. Johansson, Thin-film HTS probe coils for magnetic-resonance imaging, Chicago, IL, USA, 1993, pp. 2450-2453.
    • R.S. Withers, G.C. Liang, B.F. Cole, M. Johansson, Thin-film HTS probe coils for magnetic-resonance imaging, Chicago, IL, USA, 1993, pp. 2450-2453.
  • 20
    • 0035268774 scopus 로고    scopus 로고
    • A refined circuit model of high temperature superconducting spiral coils for MRI
    • Gao E.Z., and Ma Q.Y. A refined circuit model of high temperature superconducting spiral coils for MRI. IEEE Transactions on Applied Superconductivity 11 (2001) 403-406
    • (2001) IEEE Transactions on Applied Superconductivity , vol.11 , pp. 403-406
    • Gao, E.Z.1    Ma, Q.Y.2
  • 21
    • 21244475843 scopus 로고
    • Double-bracelet resonator Helmholtz probe for NMR experiments
    • Serfaty S., Darrasse L., and Kan S. Double-bracelet resonator Helmholtz probe for NMR experiments. Review of Scientific Instruments 66 (1995) 5522-5526
    • (1995) Review of Scientific Instruments , vol.66 , pp. 5522-5526
    • Serfaty, S.1    Darrasse, L.2    Kan, S.3
  • 24
    • 0036189843 scopus 로고    scopus 로고
    • Morphologic phenotyping with MR microscopy: the visible mouse
    • Johnson G.A., Cofer G.P., Gewalt S.L., and Hedlund L.W. Morphologic phenotyping with MR microscopy: the visible mouse. Radiology 222 (2002) 789-793
    • (2002) Radiology , vol.222 , pp. 789-793
    • Johnson, G.A.1    Cofer, G.P.2    Gewalt, S.L.3    Hedlund, L.W.4
  • 25
    • 0000899450 scopus 로고
    • Quick measurement of NMR-coil sensitivity with a dual-loop probe
    • Darrasse L., and Kassab G. Quick measurement of NMR-coil sensitivity with a dual-loop probe. Review of Scientific Instruments 64 (1993) 1841-1844
    • (1993) Review of Scientific Instruments , vol.64 , pp. 1841-1844
    • Darrasse, L.1    Kassab, G.2
  • 26
    • 0002545138 scopus 로고
    • Performance of a high-temperature superconducting resonator for high-field imaging
    • Black R.D., Early T.A., and Johnson G.A. Performance of a high-temperature superconducting resonator for high-field imaging. Journal of Magnetic Resonance Series A 113 (1995) 74-80
    • (1995) Journal of Magnetic Resonance Series A , vol.113 , pp. 74-80
    • Black, R.D.1    Early, T.A.2    Johnson, G.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.