메뉴 건너뛰기




Volumn 29, Issue 1, 2008, Pages 73-83

A mixed-mode building energy model for performance evaluation and diagnosis of existing buildings

Author keywords

[No Author keywords available]

Indexed keywords

BUILDINGS; GENETIC ALGORITHMS; MATHEMATICAL MODELS; MONITORING; OPTIMIZATION;

EID: 40949141990     PISSN: 01436244     EISSN: None     Source Type: Journal    
DOI: 10.1177/0143624407087788     Document Type: Conference Paper
Times cited : (7)

References (13)
  • 1
    • 0035483427 scopus 로고    scopus 로고
    • Evaluating the performance of building thermal mass control strategies
    • Braun J, Montgomery K. Evaluating the performance of building thermal mass control strategies. HVAC&R Research 2001; 7: 403-28.
    • (2001) HVAC&R Research , vol.7 , pp. 403-428
    • Braun, J.1    Montgomery, K.2
  • 2
    • 0034165623 scopus 로고    scopus 로고
    • EnergyPlus: Energy simulation program
    • Crawley D, Lawrie L, et al. EnergyPlus: energy simulation program. ASHRAE Journal 2000; 42: 49-56.
    • (2000) ASHRAE Journal , vol.42 , pp. 49-56
    • Crawley, D.1    Lawrie, L.2
  • 3
    • 0003972335 scopus 로고
    • Lawrence Berkeley Laboratory, Berkeley, CA, Lawrence Berkeley Laboratory
    • Lawrence Berkeley Laboratory. DOE-2 Engineering Manual Version 2.1C. Berkeley, CA, Lawrence Berkeley Laboratory, 1982.
    • (1982) DOE-2 Engineering Manual Version 2.1C
  • 4
    • 0004728815 scopus 로고    scopus 로고
    • Heating load estimation using artificial neural networks
    • Brussels, Belgium
    • Kalogirou S, Neocleous C., et al. Heating load estimation using artificial neural networks. In Proc. CLIMA 2000 Conf., Brussels, Belgium, 1997.
    • (1997) Proc. CLIMA 2000 Conf
    • Kalogirou, S.1    Neocleous, C.2
  • 5
    • 0033076160 scopus 로고    scopus 로고
    • A fourier series model to predict hourly heating and cooling energy use in commercial buildings with outdoor temperature as the only weather variable
    • Dhar A, Reddy T, et al. A fourier series model to predict hourly heating and cooling energy use in commercial buildings with outdoor temperature as the only weather variable. Journal of Solar Energy Engineering 1999; 121: 47-53.
    • (1999) Journal of Solar Energy Engineering , vol.121 , pp. 47-53
    • Dhar, A.1    Reddy, T.2
  • 6
    • 0036163187 scopus 로고    scopus 로고
    • An inverse gray-box model for transient building load prediction
    • Braun J, Chaturvedi N. An inverse gray-box model for transient building load prediction. HVAC&R Research 2002; 8: 73-99.
    • (2002) HVAC&R Research , vol.8 , pp. 73-99
    • Braun, J.1    Chaturvedi, N.2
  • 7
    • 17644422194 scopus 로고    scopus 로고
    • A simplified physical model for estimating the average air temperature in multi-zone heating systems
    • Liao Z, Dexter A. A simplified physical model for estimating the average air temperature in multi-zone heating systems. Building and Environment 2004; 39: 1013-22.
    • (2004) Building and Environment , vol.39 , pp. 1013-1022
    • Liao, Z.1    Dexter, A.2
  • 8
    • 0024608778 scopus 로고
    • Transfer functions for efficient calculation of multidimensional transient heat transfer
    • Seem JE, Klein SA, et al. Transfer functions for efficient calculation of multidimensional transient heat transfer. Journal of Heat Transfer 1989; 111: 5-12.
    • (1989) Journal of Heat Transfer , vol.111 , pp. 5-12
    • Seem, J.E.1    Klein, S.A.2
  • 9
    • 31444445721 scopus 로고    scopus 로고
    • Simplified building model for transient thermal performance estimation using GA-based parameter identification
    • Wang SW, Xu XH. Simplified building model for transient thermal performance estimation using GA-based parameter identification. International Journal of Thermal Sciences 2006; 45: 419-32.
    • (2006) International Journal of Thermal Sciences , vol.45 , pp. 419-432
    • Wang, S.W.1    Xu, X.H.2
  • 10
    • 0001095893 scopus 로고
    • Optimal control of a thermal system
    • House J, Smith T. Optimal control of a thermal system. ASHRAE Transactions 1991; 97: 991-1001.
    • (1991) ASHRAE Transactions , vol.97 , pp. 991-1001
    • House, J.1    Smith, T.2
  • 11
    • 0021584417 scopus 로고
    • Optimal control applied to air conditioning in building
    • Nizet J, Lecomte L, Litt F. Optimal control applied to air conditioning in building. ASHRAE Transactions 1984; 90(1B): 587-600.
    • (1984) ASHRAE Transactions , vol.90 , Issue.1 B , pp. 587-600
    • Nizet, J.1    Lecomte, L.2    Litt, F.3
  • 13
    • 40949088895 scopus 로고    scopus 로고
    • Carroll DL. 2001. FORTRAN Genetic algorithm (GA) driver. Version 1.7a. Available online at http://cuaerospace.com/carroll/ga.html
    • Carroll DL. 2001. FORTRAN Genetic algorithm (GA) driver. Version 1.7a. Available online at http://cuaerospace.com/carroll/ga.html, http:// cuaerospace.com/carroll/gatips.html


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.