메뉴 건너뛰기




Volumn 51, Issue 4 SUPPL. 2, 2008, Pages

Standardization of Serum Creatinine and Estimated GFR in the Kidney Early Evaluation Program (KEEP)

Author keywords

Calibration; creatinine; glomerular filtration rate (GFR) estimates

Indexed keywords

ARTICLE; ASSAY; CALIBRATION; CHRONIC KIDNEY DISEASE; CREATININE BLOOD LEVEL; GLOMERULUS FILTRATION RATE; HEALTH PROGRAM; LABORATORY TEST; STANDARDIZATION;

EID: 40949135353     PISSN: 02726386     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.ajkd.2008.01.001     Document Type: Article
Times cited : (37)

References (14)
  • 1
    • 0033574249 scopus 로고    scopus 로고
    • A more accurate method to estimate glomerular filtration rate from serum creatinine: A new prediction equation
    • Levey A.S., Bosch J.P., Lewis J.B., Greene T., Rogers N., and Roth D. A more accurate method to estimate glomerular filtration rate from serum creatinine: A new prediction equation. Ann Intern Med 130 (1999) 461-470
    • (1999) Ann Intern Med , vol.130 , pp. 461-470
    • Levey, A.S.1    Bosch, J.P.2    Lewis, J.B.3    Greene, T.4    Rogers, N.5    Roth, D.6
  • 2
    • 29744467894 scopus 로고    scopus 로고
    • Expressing the MDRD Study equation for estimating GFR with IDMS traceable (gold standard) serum creatinine values
    • (abstr)
    • Levey A.S., Coresh J., Greene T., et al. Expressing the MDRD Study equation for estimating GFR with IDMS traceable (gold standard) serum creatinine values. J Am Soc Nephrol 16 (2005) 69A (abstr)
    • (2005) J Am Soc Nephrol , vol.16
    • Levey, A.S.1    Coresh, J.2    Greene, T.3
  • 3
    • 0016916438 scopus 로고
    • Prediction of creatinine clearance from serum creatinine
    • Cockcroft D., and Gault M. Prediction of creatinine clearance from serum creatinine. Nephron 16 (1976) 31-41
    • (1976) Nephron , vol.16 , pp. 31-41
    • Cockcroft, D.1    Gault, M.2
  • 4
    • 28444470591 scopus 로고    scopus 로고
    • Variation in serum creatinine assay calibration: A practical application to glomerular filtration rate estimation
    • Murthy K., Stevens L.A., Stark P.C., and Levey A.S. Variation in serum creatinine assay calibration: A practical application to glomerular filtration rate estimation. Kidney Int 68 (2005) 1884-1887
    • (2005) Kidney Int , vol.68 , pp. 1884-1887
    • Murthy, K.1    Stevens, L.A.2    Stark, P.C.3    Levey, A.S.4
  • 5
    • 0036234755 scopus 로고    scopus 로고
    • Calibration and random variation of the serum creatinine assay as critical elements of using equations to estimate the glomerular filtration rate
    • Coresh J., Astor B., McQuillan G., et al. Calibration and random variation of the serum creatinine assay as critical elements of using equations to estimate the glomerular filtration rate. Am J Kidney Dis 39 (2002) 920-929
    • (2002) Am J Kidney Dis , vol.39 , pp. 920-929
    • Coresh, J.1    Astor, B.2    McQuillan, G.3
  • 6
    • 34147205677 scopus 로고    scopus 로고
    • Expressing the MDRD Study equation for estimating GFR with standardized serum creatinine values
    • Levey A., Coresh J., Greene T., et al. Expressing the MDRD Study equation for estimating GFR with standardized serum creatinine values. Clin Chem 53 (2007) 766-772
    • (2007) Clin Chem , vol.53 , pp. 766-772
    • Levey, A.1    Coresh, J.2    Greene, T.3
  • 7
    • 33747120659 scopus 로고    scopus 로고
    • Using standardized serum creatinine values in the Modification of Diet in Renal Disease Study equation for estimating glomerular filtration rate
    • Levey A.S., Coresh J., Greene T., et al. Using standardized serum creatinine values in the Modification of Diet in Renal Disease Study equation for estimating glomerular filtration rate. Ann Intern Med 145 (2006) 247-254
    • (2006) Ann Intern Med , vol.145 , pp. 247-254
    • Levey, A.S.1    Coresh, J.2    Greene, T.3
  • 8
    • 0033967320 scopus 로고    scopus 로고
    • General Deming regression for estimating systematic bias and its confidence interval in method-comparison studies
    • Martin R.F. General Deming regression for estimating systematic bias and its confidence interval in method-comparison studies. Clin Chem 46 (2000) 100-104
    • (2000) Clin Chem , vol.46 , pp. 100-104
    • Martin, R.F.1
  • 9
    • 0027414009 scopus 로고
    • Evaluation of regression procedures for methods comparison studies
    • Linnet K. Evaluation of regression procedures for methods comparison studies. Clin Chem 39 (1993) 424-432
    • (1993) Clin Chem , vol.39 , pp. 424-432
    • Linnet, K.1
  • 10
    • 14844325792 scopus 로고    scopus 로고
    • Creatinine measurement: State of the art in accuracy and interlaboratory harmonization
    • Miller W., Myers G., Ashwood E., et al. Creatinine measurement: State of the art in accuracy and interlaboratory harmonization. Arch Pathol Lab Med 129 (2005) 297-304
    • (2005) Arch Pathol Lab Med , vol.129 , pp. 297-304
    • Miller, W.1    Myers, G.2    Ashwood, E.3
  • 11
    • 34250783071 scopus 로고    scopus 로고
    • Impact of creatinine calibration on performance of GFR estimating equations in a pooled individual patient database
    • Stevens L.A., Manzi J., Levey A.S., et al. Impact of creatinine calibration on performance of GFR estimating equations in a pooled individual patient database. Am J Kidney Dis 50 (2007) 21-35
    • (2007) Am J Kidney Dis , vol.50 , pp. 21-35
    • Stevens, L.A.1    Manzi, J.2    Levey, A.S.3
  • 12
    • 0041610979 scopus 로고    scopus 로고
    • Reply from the authors: Estimating the prevalence of low glomerular filtration rate requires attention to the creatinine calibration assay
    • Clase C., Garg A.X., and Kiberd B. Reply from the authors: Estimating the prevalence of low glomerular filtration rate requires attention to the creatinine calibration assay. J Am Soc Nephrol 13 (2002) 2812-2816
    • (2002) J Am Soc Nephrol , vol.13 , pp. 2812-2816
    • Clase, C.1    Garg, A.X.2    Kiberd, B.3
  • 13
    • 0036235019 scopus 로고    scopus 로고
    • Prevalence of low glomerular filtration rate in nondiabetic Americans: Third National Health and Nutrition Examination Survey (NHANES III)
    • Clase C.M., Garg A.X., and Kiberd B.A. Prevalence of low glomerular filtration rate in nondiabetic Americans: Third National Health and Nutrition Examination Survey (NHANES III). J Am Soc Nephrol 13 (2002) 1338-1349
    • (2002) J Am Soc Nephrol , vol.13 , pp. 1338-1349
    • Clase, C.M.1    Garg, A.X.2    Kiberd, B.A.3
  • 14
    • 0036838741 scopus 로고    scopus 로고
    • Estimating the prevalence of low glomerular filtration rate requires attention to the creatinine assay calibration
    • discussion, 2812-2816
    • Coresh J., Eknoyan G., and Levey A.S. Estimating the prevalence of low glomerular filtration rate requires attention to the creatinine assay calibration. J Am Soc Nephrol 13 (2002) 2811-2812 discussion, 2812-2816
    • (2002) J Am Soc Nephrol , vol.13 , pp. 2811-2812
    • Coresh, J.1    Eknoyan, G.2    Levey, A.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.