메뉴 건너뛰기




Volumn 22, Issue 2, 2008, Pages 252-256

The safety and efficacy of vertebroplasty using Cortoss cement in a newly established vertebroplasty service

Author keywords

Complications; Radiology; Trauma; Tumour; Vertebra

Indexed keywords

BISPHENOL A BIS(2 HYDROXYPROPYL) ETHER DIMETHACRYLATE; BONE CEMENT; POLY(METHYL METHACRYLATE); RESIN;

EID: 40949131847     PISSN: 02688697     EISSN: 1360046X     Source Type: Journal    
DOI: 10.1080/02688690701824354     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 7344249044 scopus 로고    scopus 로고
    • Health impact associated with vertebral deformities: Results from the European Vertebral Osteoporosis Study (EVOS)
    • Matthis C, Weber U, O'Neill TW, Raspe H. Health impact associated with vertebral deformities: results from the European Vertebral Osteoporosis Study (EVOS). Osteoporos Int 1998;8:364-72.
    • (1998) Osteoporos Int , vol.8 , pp. 364-372
    • Matthis, C.1    Weber, U.2    O'Neill, T.W.3    Raspe, H.4
  • 2
    • 0033802496 scopus 로고    scopus 로고
    • Risk of mortality following clinical fractures
    • Cauley JA, Thompson DE, Ensrud KC. Risk of mortality following clinical fractures. Osteoporos Int 2000;11(7):556-61.
    • (2000) Osteoporos Int , vol.11 , Issue.7 , pp. 556-561
    • Cauley, J.A.1    Thompson, D.E.2    Ensrud, K.C.3
  • 5
    • 0032783733 scopus 로고    scopus 로고
    • Vertebroplasty: Clinical experience and follow-up results
    • Martin JB, Jean B, Sugiu K, et al. Vertebroplasty: clinical experience and follow-up results. Bone 1999;25(2 Suppl):11S-5S.
    • (1999) Bone , vol.25 , Issue.2 SUPPL.
    • Martin, J.B.1    Jean, B.2    Sugiu, K.3
  • 6
    • 0033771647 scopus 로고    scopus 로고
    • Percutaneous transpedicular vertebroplasty with PMMA: Operative technique and early results. A prospective study for the treatment of osteoporotic compression fractures
    • Heini PF, Wälchli B, Berlemann U. Percutaneous transpedicular vertebroplasty with PMMA: operative technique and early results. A prospective study for the treatment of osteoporotic compression fractures. Eur Spine J 2000;9:445-50.
    • (2000) Eur Spine J , vol.9 , pp. 445-450
    • Heini, P.F.1    Wälchli, B.2    Berlemann, U.3
  • 7
    • 0031545893 scopus 로고    scopus 로고
    • Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects
    • Jensen ME, Evans AJ, Mathis JM, et al. Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. Am J Neuroradiol 1997;18(10):1897-904.
    • (1997) Am J Neuroradiol , vol.18 , Issue.10 , pp. 1897-1904
    • Jensen, M.E.1    Evans, A.J.2    Mathis, J.M.3
  • 8
    • 38949216346 scopus 로고    scopus 로고
    • CT-guided vertebroplasty in osteoprotic vertebral fractures: Incidence of secondary fractures and impact of intradiscal cement leakages during follow-up
    • Epub DOI 10.1007/s00330-007-0694-y
    • Pitton MB, Herber S, Bletz C, et al. CT-guided vertebroplasty in osteoprotic vertebral fractures: incidence of secondary fractures and impact of intradiscal cement leakages during follow-up. Eur Radiol 2007; Epub DOI 10.1007/s00330-007-0694-y.
    • (2007) Eur Radiol
    • Pitton, M.B.1    Herber, S.2    Bletz, C.3
  • 9
    • 0034655411 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for pain relief and spinal stabilization
    • Barr JD, Barr MS, Lemley TJ, McCann RM. Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine 2000;25:923-8.
    • (2000) Spine , vol.25 , pp. 923-928
    • Barr, J.D.1    Barr, M.S.2    Lemley, T.J.3    McCann, R.M.4
  • 10
    • 12544259340 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty immediately relieves pain of osteoporotic vertebral compression fractures and prevents prolonged immobilization of patients
    • Kobayashi K, Shimoyama K, Nakamura K, Murata K. Percutaneous vertebroplasty immediately relieves pain of osteoporotic vertebral compression fractures and prevents prolonged immobilization of patients. Eur Radiol 2005;15:360-7.
    • (2005) Eur Radiol , vol.15 , pp. 360-367
    • Kobayashi, K.1    Shimoyama, K.2    Nakamura, K.3    Murata, K.4
  • 11
    • 0034515155 scopus 로고    scopus 로고
    • Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty
    • Grados F, Depriester C, Cayrolle G, et al. Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty. Rheumatology 2000;39:1410-14.
    • (2000) Rheumatology , vol.39 , pp. 1410-1414
    • Grados, F.1    Depriester, C.2    Cayrolle, G.3
  • 12
    • 32944461283 scopus 로고    scopus 로고
    • Clinical outcomes after acute osteoporotic vertebral fractures: A 2-year non-randomized trial comparing percutaneous vertebroplasty with conservative therapy
    • Diamond TH, Bryant C, Browne L, Clark WA. Clinical outcomes after acute osteoporotic vertebral fractures: a 2-year non-randomized trial comparing percutaneous vertebroplasty with conservative therapy. Med J Aust 2006;184(3):113-17.
    • (2006) Med J Aust , vol.184 , Issue.3 , pp. 113-117
    • Diamond, T.H.1    Bryant, C.2    Browne, L.3    Clark, W.A.4
  • 13
    • 0037294219 scopus 로고    scopus 로고
    • Vertebral compression fractures: Pain reduction and improvement in functional mobility after percutaneous polymethylmethacrylate vertebroplasty retrospective report of 245 cases
    • Evans AJ, Jensen ME, Kip KE, et al. Vertebral compression fractures: pain reduction and improvement in functional mobility after percutaneous polymethylmethacrylate vertebroplasty retrospective report of 245 cases. Radiology 2003;226:366-72.
    • (2003) Radiology , vol.226 , pp. 366-372
    • Evans, A.J.1    Jensen, M.E.2    Kip, K.E.3
  • 14
    • 34247164791 scopus 로고    scopus 로고
    • Pain relief following percutaneous vertebroplasty: Results of a series of 283 consecutive patients treated in a single institution
    • Anselmetti GC, Corrao G, Monica PD, et al. Pain relief following percutaneous vertebroplasty: results of a series of 283 consecutive patients treated in a single institution. Cardiovasc Intervent Radiol 2007;30:441-7.
    • (2007) Cardiovasc Intervent Radiol , vol.30 , pp. 441-447
    • Anselmetti, G.C.1    Corrao, G.2    Monica, P.D.3
  • 15
    • 24344501770 scopus 로고    scopus 로고
    • Prospective analysis of clinical outcomes after percutaneous vertebroplasty for painful osteoporotic vertebral body fractures
    • Do HM, Kim BS, Marcellus ML, Curtis L, Marks MP. Prospective analysis of clinical outcomes after percutaneous vertebroplasty for painful osteoporotic vertebral body fractures. AJNR Am J Neuroradiol 2005;26:1623-8.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 1623-1628
    • Do, H.M.1    Kim, B.S.2    Marcellus, M.L.3    Curtis, L.4    Marks, M.P.5
  • 16
    • 36549080951 scopus 로고    scopus 로고
    • Minimally invasive vertebroplasty managed by a two C-arm fluoroscopic technique
    • Epub DOI:10.1080/13645700701627654
    • Li YY, Hsu RW, Cheng CC, Huang TJ. Minimally invasive vertebroplasty managed by a two C-arm fluoroscopic technique. Minim Invasive Ther Allied Technol 2007: Epub DOI:10.1080/13645700701627654.
    • (2007) Minim Invasive Ther Allied Technol
    • Li, Y.Y.1    Hsu, R.W.2    Cheng, C.C.3    Huang, T.J.4
  • 17
    • 35848970037 scopus 로고    scopus 로고
    • Clinical evaluation of vertebroplasty for multiple-level osteoporotic spinal compression fracture in the elderly
    • Epub DOI:10.1007/s00402-007-0426-4
    • Yu SW, Yang SC, Kao YH, et al. Clinical evaluation of vertebroplasty for multiple-level osteoporotic spinal compression fracture in the elderly. Arch Orthop Trauma Surg 2008;128:97-101. Epub DOI:10.1007/s00402-007-0426-4.
    • (2008) Arch Orthop Trauma Surg , vol.128 , pp. 97-101
    • Yu, S.W.1    Yang, S.C.2    Kao, Y.H.3
  • 18
    • 34547841297 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for osteoporotic fractures
    • Afzal S, Dhar S, Vasavada NB, Akbar S. Percutaneous vertebroplasty for osteoporotic fractures. Pain Physician 2007;10:559-63.
    • (2007) Pain Physician , vol.10 , pp. 559-563
    • Afzal, S.1    Dhar, S.2    Vasavada, N.B.3    Akbar, S.4
  • 19
    • 33644926990 scopus 로고    scopus 로고
    • CT-guided percutaneous vertebroplasty in the therapy of vertebral compression fractures
    • Vogl TJ, Proschek D, Schwarz W, Mack M, Hochmuth K. CT-guided percutaneous vertebroplasty in the therapy of vertebral compression fractures. Eur Radiol 2006;16:797-803.
    • (2006) Eur Radiol , vol.16 , pp. 797-803
    • Vogl, T.J.1    Proschek, D.2    Schwarz, W.3    Mack, M.4    Hochmuth, K.5
  • 20
    • 31844454303 scopus 로고    scopus 로고
    • Prospective measurement of function and pain in patients with non-neoplastic compression fractures treated with vertebroplasty
    • Prather H, Van Dillen L, Metzler JP, Riew KD, Gilula LA. Prospective measurement of function and pain in patients with non-neoplastic compression fractures treated with vertebroplasty. J Bone Joint Surg Am 2006;88:334-41.
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 334-341
    • Prather, H.1    Van Dillen, L.2    Metzler, J.P.3    Riew, K.D.4    Gilula, L.A.5
  • 21
    • 0033750539 scopus 로고    scopus 로고
    • Value of bone scan imaging in predicting pain relief from percutaneous vertebroplasty in osteoporotic vertebral fractures
    • Maynard AS, Jensen ME, Schweickert PA, et al. Value of bone scan imaging in predicting pain relief from percutaneous vertebroplasty in osteoporotic vertebral fractures. Am J Neuroradiol 2000;21:1807-12.
    • (2000) Am J Neuroradiol , vol.21 , pp. 1807-1812
    • Maynard, A.S.1    Jensen, M.E.2    Schweickert, P.A.3
  • 22
    • 33744796591 scopus 로고    scopus 로고
    • Mechanical characterization of three percutaneous vertebroplasty biomaterials
    • Gheduzzi S, Webb JJ, Miles AW. Mechanical characterization of three percutaneous vertebroplasty biomaterials. J Mater Sci Mater Med 2006;17(5):421-6.
    • (2006) J Mater Sci Mater Med , vol.17 , Issue.5 , pp. 421-426
    • Gheduzzi, S.1    Webb, J.J.2    Miles, A.W.3
  • 23
    • 0242573007 scopus 로고    scopus 로고
    • Vertebroplasty for osteoporotic spine fracture: Prevention and treatment
    • Mehbod A, Aunoble S, Le Huec JC. Vertebroplasty for osteoporotic spine fracture: prevention and treatment. Eur Spine J 2003;12(Suppl 2):S155-62.
    • (2003) Eur Spine J , vol.12 , Issue.SUPPL. 2
    • Mehbod, A.1    Aunoble, S.2    Le Huec, J.C.3
  • 24
    • 0034773299 scopus 로고    scopus 로고
    • Comparison of a new bisphenol-a-glycidyl dimethacrylate-based cortical bone void filler with polymethyl methacrylate
    • Erbe EM, Clineff TD, Gualtieri G. Comparison of a new bisphenol-a-glycidyl dimethacrylate-based cortical bone void filler with polymethyl methacrylate. Eur Spine J 2001;10(Suppl 2):S147-52.
    • (2001) Eur Spine J , vol.10 , Issue.SUPPL. 2
    • Erbe, E.M.1    Clineff, T.D.2    Gualtieri, G.3
  • 25
    • 29144511632 scopus 로고    scopus 로고
    • Clinical results of an open prospective study of a bis-GMA composite in percutaneous vertebral augmentation
    • Palussiere J, Berge J, Gangi A, et al. Clinical results of an open prospective study of a bis-GMA composite in percutaneous vertebral augmentation. Eur Spine J 2005;14(10):982-91.
    • (2005) Eur Spine J , vol.14 , Issue.10 , pp. 982-991
    • Palussiere, J.1    Berge, J.2    Gangi, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.