Optimization of low-contrast detectability in thin-collimated modern multidetector CT using an interactive sliding-thin-slab averaging algorithm

Author keywords

Contrast; Imaging phantom; Spiral CT

Indexed keywords

ALGORITHM; ARTICLE; COLLIMATOR; CONTRAST ENHANCEMENT; IMAGE QUALITY; IMAGE RECONSTRUCTION; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 40949127029     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/RLI.0b013e3181614f2d     Document Type: Article
Times cited : (15)

References (24)
  • 1
    • 0037367904 scopus 로고    scopus 로고
    • 3-D imaging with MDCT
    • Rubin GD. 3-D imaging with MDCT. Eur J Radiol. 2003;45:S37-S41.
    • (2003) Eur J Radiol , vol.45
    • Rubin, G.D.1
  • 2
    • 28144451372 scopus 로고    scopus 로고
    • Informatics in radiology (infoRAD): Introduction to the language of three-dimensional imaging with multidetector CT
    • Dalrymple NC, Prasad SR, Freckleton MW, et al. Informatics in radiology (infoRAD): introduction to the language of three-dimensional imaging with multidetector CT. Radiographics. 2005;25:1409-1428.
    • (2005) Radiographics , vol.25 , pp. 1409-1428
    • Dalrymple, N.C.1    Prasad, S.R.2    Freckleton, M.W.3
  • 3
    • 33846037194 scopus 로고    scopus 로고
    • Routine isotropic computed tomography scanning of chest: Value of coronal and sagittal reformations
    • Rydberg J, Sandrasegaran K, Tarver RD, et al. Routine isotropic computed tomography scanning of chest: value of coronal and sagittal reformations. Invest Radiol. 2007;42:23-28.
    • (2007) Invest Radiol , vol.42 , pp. 23-28
    • Rydberg, J.1    Sandrasegaran, K.2    Tarver, R.D.3
  • 4
    • 34147179045 scopus 로고    scopus 로고
    • Automated volumetry of solid pulmonary nodules in a phantom: Accuracy across different CT scanner technologies
    • Das M, Muhlenbruch G, Katoh M, et al. Automated volumetry of solid pulmonary nodules in a phantom: accuracy across different CT scanner technologies. Invest Radiol. 2007;42:297-302.
    • (2007) Invest Radiol , vol.42 , pp. 297-302
    • Das, M.1    Muhlenbruch, G.2    Katoh, M.3
  • 5
    • 24044466768 scopus 로고    scopus 로고
    • Detection of liver metastases under 2 cm: Comparison of different acquisition protocols in four row multidetector-CT (MDCT)
    • Abdelmoumene A, Chevallier P, Chalaron M, et al. Detection of liver metastases under 2 cm: comparison of different acquisition protocols in four row multidetector-CT (MDCT). Eur Radiol. 2005;15:1881-1887.
    • (2005) Eur Radiol , vol.15 , pp. 1881-1887
    • Abdelmoumene, A.1    Chevallier, P.2    Chalaron, M.3
  • 6
    • 0036787351 scopus 로고    scopus 로고
    • Multi-detector row helical CT in preoperative assessment of small (< or = 1.5 cm) liver metastases: Is thinner collimation better?
    • Haider MA, Amitai MM, Rappaport DC, et al. Multi-detector row helical CT in preoperative assessment of small (< or = 1.5 cm) liver metastases: is thinner collimation better? Radiology. 2002;225:137-142.
    • (2002) Radiology , vol.225 , pp. 137-142
    • Haider, M.A.1    Amitai, M.M.2    Rappaport, D.C.3
  • 7
    • 0036283207 scopus 로고    scopus 로고
    • Multidetector CT: Diagnostic impact of slice thickness on detection of hypervascular hepatocellular carcinoma
    • Kawata S, Murakami T, Kim T, et al. Multidetector CT: diagnostic impact of slice thickness on detection of hypervascular hepatocellular carcinoma. AJR Am J Roentgenol. 2002;179:61-66.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 61-66
    • Kawata, S.1    Murakami, T.2    Kim, T.3
  • 8
    • 33744816514 scopus 로고    scopus 로고
    • Technologies for image distribution in hospitals
    • Kotter E, Baumann T, Jaeger D, et al. Technologies for image distribution in hospitals. Eur Radiol. 2006;16:1270-1279.
    • (2006) Eur Radiol , vol.16 , pp. 1270-1279
    • Kotter, E.1    Baumann, T.2    Jaeger, D.3
  • 9
    • 33750906756 scopus 로고    scopus 로고
    • Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets
    • Meenan C, Daly B, Toland C, et al. Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets. J Digit Imaging. 2006;19(Suppl 1):84-88.
    • (2006) J Digit Imaging , vol.19 , Issue.SUPPL. 1 , pp. 84-88
    • Meenan, C.1    Daly, B.2    Toland, C.3
  • 10
    • 0842323879 scopus 로고    scopus 로고
    • Multislice CT: Technical principles and future trends
    • Prokop M. Multislice CT: technical principles and future trends. European Radiology. 2004;13:M3-M13.
    • (2004) European Radiology , vol.13
    • Prokop, M.1
  • 11
    • 40949130082 scopus 로고    scopus 로고
    • International Electrotechnical Commission (IEC). Medical electrical equipment - 60601. Part 2-44: Particular requirements for the safety of X-ray equipment for computed tomography; 1999.
    • International Electrotechnical Commission (IEC). Medical electrical equipment - 60601. Part 2-44: Particular requirements for the safety of X-ray equipment for computed tomography; 1999.
  • 13
    • 6944256790 scopus 로고    scopus 로고
    • Engineering and algorithm design for an image processing API: A technical report on ITK - the insight toolkit
    • ed, Amsterdam: IOS Press;
    • Yoo TS, Ackerman MJ, Lorensen WE, et al. Engineering and algorithm design for an image processing API: a technical report on ITK - the insight toolkit. In: Westwood J, ed. Proceedings of Medicine Meets Virtual Reality. Amsterdam: IOS Press; 2002:586-592.
    • (2002) Proceedings of Medicine Meets Virtual Reality , pp. 586-592
    • Yoo, T.S.1    Ackerman, M.J.2    Lorensen, W.E.3
  • 14
    • 0842345477 scopus 로고    scopus 로고
    • Low-contrast detectability in volume rendering: A phantom study on multidetector-row spiral CT data
    • Shin HO, Falck CV, Galanski M. Low-contrast detectability in volume rendering: a phantom study on multidetector-row spiral CT data. Eur Radiol. 2004;14:341-349.
    • (2004) Eur Radiol , vol.14 , pp. 341-349
    • Shin, H.O.1    Falck, C.V.2    Galanski, M.3
  • 15
    • 0842335784 scopus 로고    scopus 로고
    • A statistical method of defining low contrast detectability
    • Chao EH, Toth TL, Bromberg NB, et al. A statistical method of defining low contrast detectability. Radiology. 2000;217(Suppl S):162.
    • (2000) Radiology , vol.217 , Issue.SUPPL. S , pp. 162
    • Chao, E.H.1    Toth, T.L.2    Bromberg, N.B.3
  • 16
    • 40949147832 scopus 로고    scopus 로고
    • ASTM Standard Test Method for Measurement of Computed Tomography (CT) Performance. ASTM
    • ASTM
    • ASTM. ASTM Standard Test Method for Measurement of Computed Tomography (CT) Performance. ASTM; 2001:E1695-95.
    • (2001)
  • 17
    • 15044352366 scopus 로고    scopus 로고
    • OsiriX: An open-source software for navigating in multidimensional DICOM images
    • Rosset A, Spadola L, Ratib O. OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging. 2004;17:205-216.
    • (2004) J Digit Imaging , vol.17 , pp. 205-216
    • Rosset, A.1    Spadola, L.2    Ratib, O.3
  • 18
    • 0035413321 scopus 로고    scopus 로고
    • New techniques for efficient sliding thinslab volume visualization
    • Turlington JZ, Higgins WE. New techniques for efficient sliding thinslab volume visualization. IEEE Trans Med Imaging. 2001;20:823-835.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 823-835
    • Turlington, J.Z.1    Higgins, W.E.2
  • 19
    • 33747827820 scopus 로고    scopus 로고
    • Computed tomography diagnosis of acute appendicitis. Advantages of reviewing thin-section datasets using sliding slab average intensity projection technique
    • Lee KH, Young HK, Hahn S, et al. Computed tomography diagnosis of acute appendicitis. Advantages of reviewing thin-section datasets using sliding slab average intensity projection technique. Invest Radiol. 2006;41:579-585.
    • (2006) Invest Radiol , vol.41 , pp. 579-585
    • Lee, K.H.1    Young, H.K.2    Hahn, S.3
  • 20
    • 0027323218 scopus 로고
    • STS-MIP: A new reconstruction technique for CT of the chest
    • Napel S, Rubin GD, Jeffrey RB. STS-MIP: a new reconstruction technique for CT of the chest. J Comput Assist Tomogr. 1993;17:832-838.
    • (1993) J Comput Assist Tomogr , vol.17 , pp. 832-838
    • Napel, S.1    Rubin, G.D.2    Jeffrey, R.B.3
  • 21
    • 0029787204 scopus 로고    scopus 로고
    • Sliding thin slab, minimum intensity projection technique in the diagnosis of emphysema: Histopathologic-CT correlation
    • Remy-Jardin M, Remy J, Artaud D, et al. Sliding thin slab, minimum intensity projection technique in the diagnosis of emphysema: histopathologic-CT correlation. Radiology. 1996;200:665-671.
    • (1996) Radiology , vol.200 , pp. 665-671
    • Remy-Jardin, M.1    Remy, J.2    Artaud, D.3
  • 22
    • 33644849602 scopus 로고    scopus 로고
    • Relative value of sliding-thin-slab multiplanar reformations and sliding-thin-slab maximum intensity projections as reformatting techniques in multisection CT angiography of the cervicocranial vessels
    • Ertl-Wagner BB, Bruening R, Blume J, et al. Relative value of sliding-thin-slab multiplanar reformations and sliding-thin-slab maximum intensity projections as reformatting techniques in multisection CT angiography of the cervicocranial vessels. Am J Neuroradiol. 2006;27:107-113.
    • (2006) Am J Neuroradiol , vol.27 , pp. 107-113
    • Ertl-Wagner, B.B.1    Bruening, R.2    Blume, J.3
  • 23
    • 8444252622 scopus 로고    scopus 로고
    • Image quality of thin- and thick-slice MSCT reconstructions in low-contrast objects (liver lesions) with equal doses
    • Wedegartner U, Lorenzen M, Nagel HD, et al. Image quality of thin- and thick-slice MSCT reconstructions in low-contrast objects (liver lesions) with equal doses. RoFo. 2004;176:1676-1682.
    • (2004) RoFo , vol.176 , pp. 1676-1682
    • Wedegartner, U.1    Lorenzen, M.2    Nagel, H.D.3
  • 24
    • 33750460658 scopus 로고    scopus 로고
    • Detection and characterization of benign focal liver lesions with multislice CT
    • Winterer JT, Kotter E, Ghanem N, et al. Detection and characterization of benign focal liver lesions with multislice CT. Eur Radiol. 2006;16:2427-2443.
    • (2006) Eur Radiol , vol.16 , pp. 2427-2443
    • Winterer, J.T.1    Kotter, E.2    Ghanem, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.