메뉴 건너뛰기




Volumn 178, Issue 5, 2008, Pages 591-593

Measuring blood pressure: A call to bare arms?

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; AUSCULTATION; AUTOMATION; BLOOD PRESSURE MEASUREMENT; CLINICAL EXAMINATION; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; HEART ARRHYTHMIA; HUMAN; NOTE; OSCILLOMETRY; PRACTICE GUIDELINE; VALIDATION PROCESS;

EID: 40949107633     PISSN: 08203946     EISSN: 14882329     Source Type: Journal    
DOI: 10.1503/cmaj.071787     Document Type: Note
Times cited : (6)

References (10)
  • 1
    • 0028532654 scopus 로고
    • Survey of automated noninvasive blood pressure monitors
    • Ng KG, Small CF. Survey of automated noninvasive blood pressure monitors. J Clin Eng 1994;19:452-75.
    • (1994) J Clin Eng , vol.19 , pp. 452-475
    • Ng, K.G.1    Small, C.F.2
  • 2
    • 0033543067 scopus 로고    scopus 로고
    • Accurate blood pressure measurement: Why does it matter? [editorial]
    • Campbell NRC, McKay DW. Accurate blood pressure measurement: Why does it matter? [editorial] CMAJ 1999;161:277-9.
    • (1999) CMAJ , vol.161 , pp. 277-279
    • Campbell, N.R.C.1    McKay, D.W.2
  • 3
    • 40949153343 scopus 로고    scopus 로고
    • A comparison of blood pressure measurement over a sleeved arm versus a bare arm
    • Ma G, Sabin N, Dawes M. A comparison of blood pressure measurement over a sleeved arm versus a bare arm. CMAJ 2008;178:585-9.
    • (2008) CMAJ , vol.178 , pp. 585-589
    • Ma, G.1    Sabin, N.2    Dawes, M.3
  • 4
    • 0027316251 scopus 로고
    • The effect of sleeved arms on oscillometric blood pressure measurement
    • Holleman DR Jr, Westman EC, McCrory DC, et al. The effect of sleeved arms on oscillometric blood pressure measurement. J Gen Intern Med 1993;8:325-6.
    • (1993) J Gen Intern Med , vol.8 , pp. 325-326
    • Holleman Jr, D.R.1    Westman, E.C.2    McCrory, D.C.3
  • 5
    • 0346966809 scopus 로고    scopus 로고
    • Comparison of blood pressure measurements on the bare arm, below a rolled-up sleeve, or over a sleeve
    • Kahan E, Yaphe J, Knaani-Levinz H, et al. Comparison of blood pressure measurements on the bare arm, below a rolled-up sleeve, or over a sleeve. Fam Pract 2003;20:730-2.
    • (2003) Fam Pract , vol.20 , pp. 730-732
    • Kahan, E.1    Yaphe, J.2    Knaani-Levinz, H.3
  • 6
    • 9244255780 scopus 로고    scopus 로고
    • The effect of clothes on sphygmomanometric and oscillometric blood pressure measurement
    • Liebl M, Holzgreve H, Schulz M, et al. The effect of clothes on sphygmomanometric and oscillometric blood pressure measurement. Blood Press 2004;13:279-82.
    • (2004) Blood Press , vol.13 , pp. 279-282
    • Liebl, M.1    Holzgreve, H.2    Schulz, M.3
  • 7
    • 0038460302 scopus 로고    scopus 로고
    • Chobanian AV, Bakris GL, Black HR, et al. The seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. The JNC 7 Report. JAMA 2003;289:2560-72.
    • Chobanian AV, Bakris GL, Black HR, et al. The seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. The JNC 7 Report. JAMA 2003;289:2560-72.
  • 8
    • 34250841843 scopus 로고    scopus 로고
    • Canadian Hypertension Education Program. The 2007 Canadian Hypertension Education Program recommendations for the management of hypertension: Part 1 - blood pressure measurement, diagnosis and assessment of risk
    • Padwal RS, Hemmelgarn BR, McAlister FA, et al; Canadian Hypertension Education Program. The 2007 Canadian Hypertension Education Program recommendations for the management of hypertension: part 1 - blood pressure measurement, diagnosis and assessment of risk. Can J Cardiol 2007;23:529-38.
    • (2007) Can J Cardiol , vol.23 , pp. 529-538
    • Padwal, R.S.1    Hemmelgarn, B.R.2    McAlister, F.A.3
  • 9
    • 40949098851 scopus 로고    scopus 로고
    • Digital blood pressure monitor UA-767 [instruction manual, Japan: A&D Company. Available:, accessed 2008 Jan. 21
    • Digital blood pressure monitor UA-767 [instruction manual]. Saitoma, Japan: A&D Company. Available: www.aandd.jp/products/manual/medical/ua-767. pdf (accessed 2008 Jan. 21).
    • Saitoma
  • 10
    • 0036970649 scopus 로고    scopus 로고
    • Limitations of current validation protocols for home blood pressure monitors for individual patients
    • Gerin W, Schwartz AR, Schwartz JE, et al. Limitations of current validation protocols for home blood pressure monitors for individual patients. Blood Press Monit 2002;7:313-8.
    • (2002) Blood Press Monit , vol.7 , pp. 313-318
    • Gerin, W.1    Schwartz, A.R.2    Schwartz, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.