-
2
-
-
0016068330
-
The fourier reconstruction of a head section
-
Shepp L., and Logan B. The fourier reconstruction of a head section. IEEE Trans Nucl Sci 21 (1974) 21-43
-
(1974)
IEEE Trans Nucl Sci
, vol.21
, pp. 21-43
-
-
Shepp, L.1
Logan, B.2
-
3
-
-
0012032351
-
Correction for beam hardening artefacts in computerised tomography
-
Hammersberg P., and Mangard M. Correction for beam hardening artefacts in computerised tomography. J X-ray Sci Technol 8 1 (1998) 75-93
-
(1998)
J X-ray Sci Technol
, vol.8
, Issue.1
, pp. 75-93
-
-
Hammersberg, P.1
Mangard, M.2
-
4
-
-
0018386456
-
Correction for beam hardening in computed tomography
-
Herman G.T. Correction for beam hardening in computed tomography. Phys Med Biol 24 1 (1979) 81-106
-
(1979)
Phys Med Biol
, vol.24
, Issue.1
, pp. 81-106
-
-
Herman, G.T.1
-
5
-
-
0030867231
-
A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine
-
Joseph P.M., and Ruth C. A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine. Med Phys 24 10 (1997) 1629-1634
-
(1997)
Med Phys
, vol.24
, Issue.10
, pp. 1629-1634
-
-
Joseph, P.M.1
Ruth, C.2
-
6
-
-
0019606465
-
CT reprojection polychromaticity correction for three attenuators
-
Olson E.A., Han K.S., and Pisano D.J. CT reprojection polychromaticity correction for three attenuators. IEEE Trans Nucl Sci 39 1 (1981) 3628-3640
-
(1981)
IEEE Trans Nucl Sci
, vol.39
, Issue.1
, pp. 3628-3640
-
-
Olson, E.A.1
Han, K.S.2
Pisano, D.J.3
-
7
-
-
2542464481
-
A model-based correction method for beam hardening artefacts in X-ray microtomography
-
Van de Casteele E., Van Dyck D., Sijbers J., and Raman E. A model-based correction method for beam hardening artefacts in X-ray microtomography. J X-ray Sci Technol 12 1 (2004) 43-57
-
(2004)
J X-ray Sci Technol
, vol.12
, Issue.1
, pp. 43-57
-
-
Van de Casteele, E.1
Van Dyck, D.2
Sijbers, J.3
Raman, E.4
-
8
-
-
40849085067
-
-
Kasperl S. Qualitätsverbesserungen durch referenzfreie Artefaktreduzierung und Oberflächennormierung in der industriellen 3D-Computertomographie. Dissertation, Friedrich-Alexander Universität Erlangen-Nürnberg; 2005.
-
Kasperl S. Qualitätsverbesserungen durch referenzfreie Artefaktreduzierung und Oberflächennormierung in der industriellen 3D-Computertomographie. Dissertation, Friedrich-Alexander Universität Erlangen-Nürnberg; 2005.
-
-
-
-
9
-
-
33646460131
-
Empirical cupping correction: a first-order raw data precorrection for cone-beam computed tomography
-
Kachelrieß M., Sourbelle K., and Kalender W.A. Empirical cupping correction: a first-order raw data precorrection for cone-beam computed tomography. Med Phys 33 5 (2006) 1269-1274
-
(2006)
Med Phys
, vol.33
, Issue.5
, pp. 1269-1274
-
-
Kachelrieß, M.1
Sourbelle, K.2
Kalender, W.A.3
-
10
-
-
0017108614
-
Energy selective reconstructions in X-ray computerized tomography
-
Alvarez R.E., and Macovski A. Energy selective reconstructions in X-ray computerized tomography. Phys Med Biol 21 (1976) 733-744
-
(1976)
Phys Med Biol
, vol.21
, pp. 733-744
-
-
Alvarez, R.E.1
Macovski, A.2
-
11
-
-
0019389495
-
Generalized image combinations in dual KVP digital radiography
-
Lehmann L.A., Alvarez R.E., Macovski A., Brody W.R., Pelc N.J., Rieder S.J., et al. Generalized image combinations in dual KVP digital radiography. Med Phys 8 5 (1981) 659-667
-
(1981)
Med Phys
, vol.8
, Issue.5
, pp. 659-667
-
-
Lehmann, L.A.1
Alvarez, R.E.2
Macovski, A.3
Brody, W.R.4
Pelc, N.J.5
Rieder, S.J.6
-
12
-
-
40849119657
-
-
Fuchs TOJ. Strahlaufhärtungskorrekturen in der Computer-Tomographie. Inaugural-Dissertation, Friedrich-Alexander Universität Erlangen-Nürnberg; 1998.
-
Fuchs TOJ. Strahlaufhärtungskorrekturen in der Computer-Tomographie. Inaugural-Dissertation, Friedrich-Alexander Universität Erlangen-Nürnberg; 1998.
-
-
-
-
13
-
-
0018404829
-
Post-reconstruction method for beam hardening in computerized tomography
-
Nalcioglu O., and Lou R.Y. Post-reconstruction method for beam hardening in computerized tomography. Phys Med Biol 24 2 (1979) 330-340
-
(1979)
Phys Med Biol
, vol.24
, Issue.2
, pp. 330-340
-
-
Nalcioglu, O.1
Lou, R.Y.2
-
14
-
-
0031060810
-
Surface interpolation with radial basis functions for medical imaging
-
Carr J.C., and Fright W.R. Surface interpolation with radial basis functions for medical imaging. IEEE Trans Med Imag 16 1 (1997) 96-107
-
(1997)
IEEE Trans Med Imag
, vol.16
, Issue.1
, pp. 96-107
-
-
Carr, J.C.1
Fright, W.R.2
-
16
-
-
40849139122
-
-
Wenig P. Untersuchung von Störeinflüssen auf das dimensionelle Messen mittels Röntgencomputertomographie. Diplomarbeit, Friedrich-Alexander Universität Erlangen-Nürnberg; 1998.
-
Wenig P. Untersuchung von Störeinflüssen auf das dimensionelle Messen mittels Röntgencomputertomographie. Diplomarbeit, Friedrich-Alexander Universität Erlangen-Nürnberg; 1998.
-
-
-
|