메뉴 건너뛰기




Volumn 113, Issue 1, 2008, Pages 3-15

CT-guided percutaneous transthoracic biopsy in the diagnosis of mediastinal masses: Evaluation of 73 procedures;Biopsia percutanea transtoracica TC guidata nella diagnosi degli espansi del mediastino: Valutazione di 73 procedure

Author keywords

Biopsy; Complications; Computed tomography (CT); Diagnostic accuracy; Guidance; Mediastinum

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BLEEDING; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; FOLLOW UP; GRANULOMA; HODGKIN DISEASE; HUMAN; HUMAN TISSUE; LYMPHOEPITHELIOMA; MAJOR CLINICAL STUDY; MALE; MEDIASTINUM MASS; METASTASIS; NEEDLE BIOPSY; NONHODGKIN LYMPHOMA; OUTCOME ASSESSMENT; PERCUTANEOUS BIOPSY; PNEUMOTHORAX; SCHOOL CHILD; SENSITIVITY AND SPECIFICITY; TERATOMA; THYMOMA; TRANSTHORACIC BIOPSY;

EID: 40749136327     PISSN: 00338362     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11547-008-0233-1     Document Type: Article
Times cited : (57)

References (20)
  • 1
    • 33646231771 scopus 로고    scopus 로고
    • The anterior mediastinum: Diseases (Il mediastino anteriore: Patologie)
    • Priola AM, Priola SM, Cardinale L et al (2006) The anterior mediastinum: diseases (Il mediastino anteriore: patologie). Radiol med 11:312-342
    • (2006) Radiol Med , vol.11 , pp. 312-342
    • Priola, A.M.1    Priola, S.M.2    Cardinale, L.3
  • 2
    • 33646248910 scopus 로고    scopus 로고
    • The anterior mediastinum: Anatomy and imaging procedures (Il mediastino anteriore: Anatomia e tecniche di studio)
    • Priola SM, Priola AM, Cardinale L et al (2006) The anterior mediastinum: anatomy and imaging procedures (Il mediastino anteriore: anatomia e tecniche di studio). Radiol med 11:295-311
    • (2006) Radiol Med , vol.11 , pp. 295-311
    • Priola, S.M.1    Priola, A.M.2    Cardinale, L.3
  • 3
    • 0020639084 scopus 로고
    • Fine-needle aspiration biopsy of mediastinal masses: Evaluation of 136 experiences
    • Adler OB, Rosenberg A, Peleg H (1983) Fine-needle aspiration biopsy of mediastinal masses: evaluation of 136 experiences. AJR Am J Roentgenol 140:893-896
    • (1983) AJR Am J Roentgenol , vol.140 , pp. 893-896
    • Adler, O.B.1    Rosenberg, A.2    Peleg, H.3
  • 4
    • 0021273414 scopus 로고
    • Percutaneous fine-needle aspiration biopsy of mediastinal lesions
    • Weisbrod GL, Lyons DJ, Tao LC et al (1984) Percutaneous fine-needle aspiration biopsy of mediastinal lesions. AJR Am J Roentgenol 143:525-529
    • (1984) AJR Am J Roentgenol , vol.143 , pp. 525-529
    • Weisbrod, G.L.1    Lyons, D.J.2    Tao, L.C.3
  • 5
    • 0025783370 scopus 로고
    • Anterior mediastinal masses: Utility of transthoracic needle biopsy
    • Herman SJ, Holub RV, Weisbrod GL et al (1991) Anterior mediastinal masses: utility of transthoracic needle biopsy. Radiology 180:167-170
    • (1991) Radiology , vol.180 , pp. 167-170
    • Herman, S.J.1    Holub, R.V.2    Weisbrod, G.L.3
  • 6
  • 7
    • 20444466557 scopus 로고    scopus 로고
    • Imaging-guided percutaneous biopsy of mediastinal lesions: Different approaches and anatomic considerations
    • Gupta S, Seaberg K, Wallace MJ et al (2005) Imaging-guided percutaneous biopsy of mediastinal lesions: different approaches and anatomic considerations. Radiographics 25:786-788
    • (2005) Radiographics , vol.25 , pp. 786-788
    • Gupta, S.1    Seaberg, K.2    Wallace, M.J.3
  • 8
    • 0028204968 scopus 로고
    • Impact of positive findings at image-guided biopsy of lymphoma on patient care: Evaluation of clinical history, needle size, and pathologic findings on biopsy performance
    • Silverman SG, Lee BY, Mueller PR et al (1994) Impact of positive findings at image-guided biopsy of lymphoma on patient care: evaluation of clinical history, needle size, and pathologic findings on biopsy performance. Radiology 190:759-764
    • (1994) Radiology , vol.190 , pp. 759-764
    • Silverman, S.G.1    Lee, B.Y.2    Mueller, P.R.3
  • 9
    • 0029737607 scopus 로고    scopus 로고
    • Image-guided core-needle biopsy in malignant lymphoma: Experience with 100 patients that suggests the technique is reliable
    • Ben-Yehuda D, Polliack A, Okon E et al (1996) Image-guided core-needle biopsy in malignant lymphoma: experience with 100 patients that suggests the technique is reliable. J Clin Oncol 14:2431-2434
    • (1996) J Clin Oncol , vol.14 , pp. 2431-2434
    • Ben-Yehuda, D.1    Polliack, A.2    Okon, E.3
  • 10
    • 0030051348 scopus 로고    scopus 로고
    • Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients
    • Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiolog 198:715-720
    • (1996) Radiolog , vol.198 , pp. 715-720
    • Klein, J.S.1    Salomon, G.2    Stewart, E.A.3
  • 11
    • 0000289384 scopus 로고
    • A new technique for transthoracic biopsy of lung changes
    • Nordenström B (1965) A new technique for transthoracic biopsy of lung changes. Br J Radiol 38:550-553
    • (1965) Br J Radiol , vol.38 , pp. 550-553
    • Nordenström, B.1
  • 12
    • 0004683312 scopus 로고
    • Paraxiphoid approach to the mediastinum for mediastinography and mediastinal needle biopsy
    • Nordenström B (1967) Paraxiphoid approach to the mediastinum for mediastinography and mediastinal needle biopsy. Invest Radiol 2:141-146
    • (1967) Invest Radiol , vol.2 , pp. 141-146
    • Nordenström, B.1
  • 13
    • 0015344424 scopus 로고
    • Paravertebral approach to the posterior mediastinum for mediastinography and needle biopsy
    • Nordenström B (1972) Paravertebral approach to the posterior mediastinum for mediastinography and needle biopsy. Acta Radiol [Diagn] (Stockh) 13:298-304
    • (1972) Acta Radiol [Diagn] (Stockh) , vol.13 , pp. 298-304
    • Nordenström, B.1
  • 14
    • 0017643341 scopus 로고
    • Transthoracic needle biopsy of mediastinal and hilar lesions
    • Jereb M, Us-Kräsovec M (1977) Transthoracic needle biopsy of mediastinal and hilar lesions. Cancer 40:1354-1357
    • (1977) Cancer , vol.40 , pp. 1354-1357
    • Jereb, M.1    Us-Kräsovec, M.2
  • 15
    • 0027324363 scopus 로고
    • Percutaneous needle biopsy of the mediastinum: Review of 94 procedures
    • Morrisey B, Adams H, Gibbs AR et al (1993) Percutaneous needle biopsy of the mediastinum: review of 94 procedures. Thorax 48:632-637
    • (1993) Thorax , vol.48 , pp. 632-637
    • Morrisey, B.1    Adams, H.2    Gibbs, A.R.3
  • 16
    • 0032867412 scopus 로고    scopus 로고
    • Percutaneous core needle biopsy in the diagnosis of mediastinal tumors
    • Greif J, Staroselsky AN, Gernjac M et al (1999) Percutaneous core needle biopsy in the diagnosis of mediastinal tumors. Lung Cancer 25:169-173
    • (1999) Lung Cancer , vol.25 , pp. 169-173
    • Greif, J.1    Staroselsky, A.N.2    Gernjac, M.3
  • 18
    • 33750548656 scopus 로고    scopus 로고
    • Nodular sclerosing Hodgkin disease presenting as a sternal mass
    • Priola SM, Priola AM, Cataldi A et al (2006) Nodular sclerosing Hodgkin disease presenting as a sternal mass. Brit J Haematol 135:594
    • (2006) Brit J Haematol , vol.135 , pp. 594
    • Priola, S.M.1    Priola, A.M.2    Cataldi, A.3
  • 19
    • 0023011878 scopus 로고
    • Fine-needle aspiration biopsy of the mediastinum
    • Linder J, Olsen GA, Johnston WW (1986) Fine-needle aspiration biopsy of the mediastinum. Am J Med 81:1005-1008
    • (1986) Am J Med , vol.81 , pp. 1005-1008
    • Linder, J.1    Olsen, G.A.2    Johnston, W.W.3
  • 20
    • 0023235886 scopus 로고
    • Percutaneous fine-needle aspiration biopsy of the mediastinum
    • Weisbrod GL (1987) Percutaneous fine-needle aspiration biopsy of the mediastinum. Clin Chest Med 8:27-41
    • (1987) Clin Chest Med , vol.8 , pp. 27-41
    • Weisbrod, G.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.