메뉴 건너뛰기




Volumn 81, Issue 963, 2008, Pages 214-218

Trends in compressed breast thickness and radiation dose in breast screening mammography

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BREAST EXAMINATION; DOSIMETRY; FEMALE; HEALTH SURVEY; HUMAN; MAJOR CLINICAL STUDY; MAMMOGRAPHY; OBESITY; RADIATION DOSE; SCREENING TEST; STATISTICAL SIGNIFICANCE; THICKNESS; BODY MASS; BODY SIZE; BREAST; CLINICAL TRIAL; HISTOLOGY; LIGATION; MIDDLE AGED; MULTICENTER STUDY; RADIOGRAPHY; UNITED KINGDOM;

EID: 40749133395     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/90916004     Document Type: Article
Times cited : (16)

References (12)
  • 1
    • 14644404889 scopus 로고    scopus 로고
    • The commissioning and routine testing of mammographic X-ray systems
    • No. 89. York: Institute of Physics and Engineering in Medicine
    • The commissioning and routine testing of mammographic X-ray systems. IPEM Report No. 89. York: Institute of Physics and Engineering in Medicine, 2005.
    • (2005) IPEM Report
  • 2
    • 0033778108 scopus 로고    scopus 로고
    • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol
    • Dance DR, Skinner CL, Young KC, Beckett JR, Kotre CJ. Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol. Phys Med Biol 2000;45:3225-40.
    • (2000) Phys Med Biol , vol.45 , pp. 3225-3240
    • Dance, D.R.1    Skinner, C.L.2    Young, K.C.3    Beckett, J.R.4    Kotre, C.J.5
  • 3
    • 16344377517 scopus 로고    scopus 로고
    • Radiation doses received in the UK Breast Screening Programme in 2001 and 2002
    • Young KC, Burch A, Oduko JM. Radiation doses received in the UK Breast Screening Programme in 2001 and 2002. Br J Radiol 2005;78:207-18.
    • (2005) Br J Radiol , vol.78 , pp. 207-218
    • Young, K.C.1    Burch, A.2    Oduko, J.M.3
  • 4
    • 0029051017 scopus 로고
    • Assessment of mean glandular dose in mammography
    • Faulkner K, Law J, Robson KJ. Assessment of mean glandular dose in mammography. Br J Radiol 1995;68:877-81.
    • (1995) Br J Radiol , vol.68 , pp. 877-881
    • Faulkner, K.1    Law, J.2    Robson, K.J.3
  • 5
    • 0031748636 scopus 로고    scopus 로고
    • A pilot study of radiation doses received in the United Kingdom Breast Screening Programme
    • Burch A, Goodman DA. A pilot study of radiation doses received in the United Kingdom Breast Screening Programme. Br J Radiol 1998;71:517-27.
    • (1998) Br J Radiol , vol.71 , pp. 517-527
    • Burch, A.1    Goodman, D.A.2
  • 6
    • 42249114637 scopus 로고    scopus 로고
    • Social trends 35. London: Office for National Statistics, 2005.
    • Social trends 35. London: Office for National Statistics, 2005.
  • 7
    • 42249103761 scopus 로고    scopus 로고
    • Social trends 30. London: Office for National Statistics, 1997.
    • Social trends 30. London: Office for National Statistics, 1997.
  • 9
    • 0024986312 scopus 로고
    • Carlo calculation of conversion factors for the estimation of mean glandular breast dose
    • Dance DR. Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose. Phys Med Biol 1990;35:1211-19.
    • (1990) Phys Med Biol , vol.35 , pp. 1211-1219
    • Monte, D.D.R.1
  • 10
    • 42249100980 scopus 로고    scopus 로고
    • Commissioning and routine testing of full field digital mammography systems. NHSBSP Equipment Report 0604. Sheffield: NHS Cancer Screening Programmes, 2006.
    • Commissioning and routine testing of full field digital mammography systems. NHSBSP Equipment Report 0604. Sheffield: NHS Cancer Screening Programmes, 2006.
  • 11
    • 42249086762 scopus 로고    scopus 로고
    • Guidance on the establishment and use of diagnostic reference levels for medical X-ray examinations. IPEM Report No. 88. York: Institute of Physics and Engineering in Medicine, 2004
    • Guidance on the establishment and use of diagnostic reference levels for medical X-ray examinations. IPEM Report No. 88. York: Institute of Physics and Engineering in Medicine, 2004.
  • 12
    • 0034021339 scopus 로고    scopus 로고
    • Dosimetric implications of age related glandular changes in screening mammography
    • Beckett JR, Kotre CJ. Dosimetric implications of age related glandular changes in screening mammography. Phys Med Biol 2000;45:801-13.
    • (2000) Phys Med Biol , vol.45 , pp. 801-813
    • Beckett, J.R.1    Kotre, C.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.