메뉴 건너뛰기




Volumn 130, Issue 1, 2008, Pages 187-192

Copper(II)-selective electrodes based on a novel charged carrier and preliminary application of field-effect transistor type checker

Author keywords

Calboxylated thiacrown ether; Charged copper(II) carrier; Copper(II) selective potentiometric sensors; FET checker application; Ion selective electrodes (ISEs); Ion selective field effect transistors (ISFETs); Potentiometric titration application; Single drop analysis

Indexed keywords

ELECTRODES; FIELD EFFECT TRANSISTORS; POLYVINYL CHLORIDES;

EID: 40749118954     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2007.07.120     Document Type: Article
Times cited : (28)

References (33)
  • 1
    • 27844436729 scopus 로고    scopus 로고
    • Ion-selective electrodes
    • Tani Y., and Umezawa Y. Ion-selective electrodes. Sens. Lett. 3 (2005) 99-107
    • (2005) Sens. Lett. , vol.3 , pp. 99-107
    • Tani, Y.1    Umezawa, Y.2
  • 2
    • 2342578719 scopus 로고    scopus 로고
    • Response time of ion-selective electrodes
    • Macca C. Response time of ion-selective electrodes. Anal. Chim. Acta 512 (2004) 183-190
    • (2004) Anal. Chim. Acta , vol.512 , pp. 183-190
    • Macca, C.1
  • 3
    • 1842734652 scopus 로고    scopus 로고
    • The phase-boundary potential model
    • Bakker E., Bühlmann P., and Pretsch E. The phase-boundary potential model. Talanta 63 (2004) 3-20
    • (2004) Talanta , vol.63 , pp. 3-20
    • Bakker, E.1    Bühlmann, P.2    Pretsch, E.3
  • 4
    • 40749121967 scopus 로고    scopus 로고
    • Ion-selective electrodes
    • Katsu T. Ion-selective electrodes. Bunseki (2004) 319-323
    • (2004) Bunseki , pp. 319-323
    • Katsu, T.1
  • 5
    • 0842303115 scopus 로고    scopus 로고
    • Ionophore-based ion-selective potentiometric and optical sensors
    • Johnson R.D., and Bachas L.G. Ionophore-based ion-selective potentiometric and optical sensors. Anal. Bioanal. Chem. 376 (2003) 328-341
    • (2003) Anal. Bioanal. Chem. , vol.376 , pp. 328-341
    • Johnson, R.D.1    Bachas, L.G.2
  • 6
    • 1542737884 scopus 로고    scopus 로고
    • Recent trend in ion-sensing research
    • Yajima S., and Kimura K. Recent trend in ion-sensing research. Bunseki Kagaku 49 (2000) 279-296
    • (2000) Bunseki Kagaku , vol.49 , pp. 279-296
    • Yajima, S.1    Kimura, K.2
  • 7
    • 0001325218 scopus 로고    scopus 로고
    • Polymer membrane ion-selective electrodes-What are the limits
    • Bakker E., Bühlmann P., and Pretsch E. Polymer membrane ion-selective electrodes-What are the limits. Electroanalysis 11 (1999) 915-933
    • (1999) Electroanalysis , vol.11 , pp. 915-933
    • Bakker, E.1    Bühlmann, P.2    Pretsch, E.3
  • 8
    • 0032099044 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    • Bühlmann P., Pretsch E., and Bakker E. Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors. Chem. Rev. 98 (1998) 1593-1687
    • (1998) Chem. Rev. , vol.98 , pp. 1593-1687
    • Bühlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 10
    • 0347207469 scopus 로고    scopus 로고
    • Ion sensor
    • Wakida S. Ion sensor. Bunseki (1997) 921-927
    • (1997) Bunseki , pp. 921-927
    • Wakida, S.1
  • 11
    • 40749125567 scopus 로고
    • Ion sensor
    • Wakida S. Ion sensor. Bunseki (1991) 977-982
    • (1991) Bunseki , pp. 977-982
    • Wakida, S.1
  • 12
    • 0342369367 scopus 로고    scopus 로고
    • Cationic or anionic sites? Selectivity optimization of ion-selective electrodes based on charged ionophores
    • Amemiya S., Bühlmann P., Pretsch E., Rusterholz B., and Umezawa Y. Cationic or anionic sites? Selectivity optimization of ion-selective electrodes based on charged ionophores. Anal. Chem. 72 (2000) 1618-1631
    • (2000) Anal. Chem. , vol.72 , pp. 1618-1631
    • Amemiya, S.1    Bühlmann, P.2    Pretsch, E.3    Rusterholz, B.4    Umezawa, Y.5
  • 13
    • 0027179859 scopus 로고
    • Potentiometric ion sensors based on natural carboxylic polyether ionophores and their derivatives
    • Suzuki K., and Tohda K. Potentiometric ion sensors based on natural carboxylic polyether ionophores and their derivatives. Trac-Trend Anal. Chem. 12 (1993) 287-296
    • (1993) Trac-Trend Anal. Chem. , vol.12 , pp. 287-296
    • Suzuki, K.1    Tohda, K.2
  • 14
    • 0034724819 scopus 로고    scopus 로고
    • Liquid-liquid extraction of platinum(II) with cyclic tetrathioethers
    • Saito K., Taninaka I., Yamamoto Y., Murakami S., and Muromatsu A. Liquid-liquid extraction of platinum(II) with cyclic tetrathioethers. Talanta 51 (2000) 913-919
    • (2000) Talanta , vol.51 , pp. 913-919
    • Saito, K.1    Taninaka, I.2    Yamamoto, Y.3    Murakami, S.4    Muromatsu, A.5
  • 15
    • 0032145848 scopus 로고    scopus 로고
    • Extraction behaviour of copper(II) and silver(I) with a thiacrown ether carboxylic acid, 2-(3,6,10,13-tetrathiacyclotetradec-1-oxy)hexanoic acid
    • Saito K., Taninaka I., Murakami S., and Muromatsu A. Extraction behaviour of copper(II) and silver(I) with a thiacrown ether carboxylic acid, 2-(3,6,10,13-tetrathiacyclotetradec-1-oxy)hexanoic acid. Talanta 46 (1998) 1187-1194
    • (1998) Talanta , vol.46 , pp. 1187-1194
    • Saito, K.1    Taninaka, I.2    Murakami, S.3    Muromatsu, A.4
  • 16
    • 0028555903 scopus 로고
    • Synthesis of thiacrown ether carboxylic-acids and their characteristics as extractants for metal-ions
    • Saito K., Taninaka I., Murakami S., and Muromatsu A. Synthesis of thiacrown ether carboxylic-acids and their characteristics as extractants for metal-ions. Anal. Chim. Acta 299 (1994) 137-144
    • (1994) Anal. Chim. Acta , vol.299 , pp. 137-144
    • Saito, K.1    Taninaka, I.2    Murakami, S.3    Muromatsu, A.4
  • 17
    • 0027936446 scopus 로고
    • Liquid-liquid-extraction of copper(II) with cyclic tetrathioethers
    • Saito K., Murakami S., Muromatsu A., and Sekido E. Liquid-liquid-extraction of copper(II) with cyclic tetrathioethers. Anal. Chim. Acta 294 (1994) 329-335
    • (1994) Anal. Chim. Acta , vol.294 , pp. 329-335
    • Saito, K.1    Murakami, S.2    Muromatsu, A.3    Sekido, E.4
  • 18
    • 0021183812 scopus 로고
    • The selective extraction and spectrophotometric determination of copper and silver by the use of a thiacrown compound, 1,4,8,11-terathiacyclotetradecane
    • Saito K., Masuda Y., and Sekido E. The selective extraction and spectrophotometric determination of copper and silver by the use of a thiacrown compound, 1,4,8,11-terathiacyclotetradecane. Bull. Chem. Soc. Jpn. 57 (1984) 189-193
    • (1984) Bull. Chem. Soc. Jpn. , vol.57 , pp. 189-193
    • Saito, K.1    Masuda, Y.2    Sekido, E.3
  • 19
    • 0000766525 scopus 로고
    • Liquid liquid extraction of metal-ions by the thiacrown compound 1,4,8,11-terathiacyclotetradecane
    • Saito K., Masuda Y., and Sekido E. Liquid liquid extraction of metal-ions by the thiacrown compound 1,4,8,11-terathiacyclotetradecane. Anal. Chim. Acta 151 (1983) 447-455
    • (1983) Anal. Chim. Acta , vol.151 , pp. 447-455
    • Saito, K.1    Masuda, Y.2    Sekido, E.3
  • 20
    • 0002996483 scopus 로고
    • A PVC matrix membrane copper ion-selective electrode based on a macrocyclic polytiaether
    • Kamata S., Higo M., Kamibeppu T., and Tanaka I. A PVC matrix membrane copper ion-selective electrode based on a macrocyclic polytiaether. Chem. Lett. (1982) 287-288
    • (1982) Chem. Lett. , pp. 287-288
    • Kamata, S.1    Higo, M.2    Kamibeppu, T.3    Tanaka, I.4
  • 21
    • 0023737682 scopus 로고
    • Copper(II)-selective electrodes based on macrocyclic polythiaethers
    • Kamata S., Yamasaki K., Higo M., Bhale A., and Fukunaga Y. Copper(II)-selective electrodes based on macrocyclic polythiaethers. Analyst 113 (1988) 45-47
    • (1988) Analyst , vol.113 , pp. 45-47
    • Kamata, S.1    Yamasaki, K.2    Higo, M.3    Bhale, A.4    Fukunaga, Y.5
  • 22
    • 0024106504 scopus 로고
    • Copper(II)-selective electrode using thiuram disulfide neutral carriers
    • Kamata S., Bhale A., Fukunaga Y., and Murata H. Copper(II)-selective electrode using thiuram disulfide neutral carriers. Anal. Chem. 60 (1988) 2464-2467
    • (1988) Anal. Chem. , vol.60 , pp. 2464-2467
    • Kamata, S.1    Bhale, A.2    Fukunaga, Y.3    Murata, H.4
  • 23
    • 0037144295 scopus 로고    scopus 로고
    • Highly selective Cu(II) PVC membrane electrode based on 3,6,9,14-tetrathiabicyclo[9.2.1]tetradeca-11,13-diene as a suitable neutral ionophore
    • Mashhadizadeh M.H., Mostafavi A., Razavi R., and Shamsipur M. Highly selective Cu(II) PVC membrane electrode based on 3,6,9,14-tetrathiabicyclo[9.2.1]tetradeca-11,13-diene as a suitable neutral ionophore. Sens. Actuator B: Chem. 86 (2002) 222-228
    • (2002) Sens. Actuator B: Chem. , vol.86 , pp. 222-228
    • Mashhadizadeh, M.H.1    Mostafavi, A.2    Razavi, R.3    Shamsipur, M.4
  • 24
    • 0036670287 scopus 로고    scopus 로고
    • A 9,10-anthraquinone derivative having two propenyl arms as a neutral ionophore for highly selective and sensitive membrane sensors for copper(II) ion
    • Shamsipur M., Avanes A., Javanbakht M., Ganjali M.R., and Sharghi H. A 9,10-anthraquinone derivative having two propenyl arms as a neutral ionophore for highly selective and sensitive membrane sensors for copper(II) ion. Anal. Sci. 18 (2002) 875-880
    • (2002) Anal. Sci. , vol.18 , pp. 875-880
    • Shamsipur, M.1    Avanes, A.2    Javanbakht, M.3    Ganjali, M.R.4    Sharghi, H.5
  • 25
    • 0035944967 scopus 로고    scopus 로고
    • Copper(II)-selective membrane electrodes based on some recently synthesized mixed aza-thioether crowns containing a 1,10-phenanthroline sub-unit
    • Shamsipur M., Javanbakht M., Mousavi M.F., Ganjali M.R., Lippolis V., Garau A., and Tei L. Copper(II)-selective membrane electrodes based on some recently synthesized mixed aza-thioether crowns containing a 1,10-phenanthroline sub-unit. Talanta 55 (2001) 1047-1054
    • (2001) Talanta , vol.55 , pp. 1047-1054
    • Shamsipur, M.1    Javanbakht, M.2    Mousavi, M.F.3    Ganjali, M.R.4    Lippolis, V.5    Garau, A.6    Tei, L.7
  • 26
    • 10644291880 scopus 로고    scopus 로고
    • Copper-selective PVC membrane electrodes based on salens as carriers
    • Fakhari A.R., Raji T.A., and Naeimi H.H. Copper-selective PVC membrane electrodes based on salens as carriers. Sens. Actuator B: Chem. 104 (2005) 317-323
    • (2005) Sens. Actuator B: Chem. , vol.104 , pp. 317-323
    • Fakhari, A.R.1    Raji, T.A.2    Naeimi, H.H.3
  • 27
    • 0141761152 scopus 로고    scopus 로고
    • Copper(II)-selective membrane electrode based on hydrotris(3-isopropylpyrazolyl)methane in a poly(vinyl chloride) matrix
    • Yoshimoto S., Mukai H., Kitano T., and Sohrin Y. Copper(II)-selective membrane electrode based on hydrotris(3-isopropylpyrazolyl)methane in a poly(vinyl chloride) matrix. Anal. Chim. Acta 494 (2003) 207-213
    • (2003) Anal. Chim. Acta , vol.494 , pp. 207-213
    • Yoshimoto, S.1    Mukai, H.2    Kitano, T.3    Sohrin, Y.4
  • 29
    • 0029278026 scopus 로고
    • A preliminary application of highly sensitive nitrate ISFETs to acid-rain monitoring
    • Wakida S., Oizaki T., Yamane M., and Higashi K. A preliminary application of highly sensitive nitrate ISFETs to acid-rain monitoring. Sens. Actuator B: Chem. 24-25 (1995) 222-224
    • (1995) Sens. Actuator B: Chem. , vol.24-25 , pp. 222-224
    • Wakida, S.1    Oizaki, T.2    Yamane, M.3    Higashi, K.4
  • 30
    • 26944500693 scopus 로고    scopus 로고
    • Response mechanism of additive salt effects of potassium-selective neutral carrier based electrode using their liquid membrane based ion-sensitive field-effect transistors
    • Wakida S., Masadome T., Imato T., Kurosawa S., and Shibutani Y. Response mechanism of additive salt effects of potassium-selective neutral carrier based electrode using their liquid membrane based ion-sensitive field-effect transistors. Anal. Sci. 17 (2001) i1671-i1674
    • (2001) Anal. Sci. , vol.17
    • Wakida, S.1    Masadome, T.2    Imato, T.3    Kurosawa, S.4    Shibutani, Y.5
  • 31
    • 0000560649 scopus 로고
    • Transition metal ion-selective membrane electrodes based on complexing compounds with heteroatoms. Part II. Complexing compounds containing sulphur atoms
    • Brzózka Z. Transition metal ion-selective membrane electrodes based on complexing compounds with heteroatoms. Part II. Complexing compounds containing sulphur atoms. Analyst 113 (1988) 1803-1805
    • (1988) Analyst , vol.113 , pp. 1803-1805
    • Brzózka, Z.1
  • 32
    • 0001626956 scopus 로고    scopus 로고
    • Copper(II)-selective membrane electrode based on a recently synthesized macrocyclic diamide
    • Shamsipur M., Rouhani S., Ganjali M.R., Eshghi H., and Sharghi H. Copper(II)-selective membrane electrode based on a recently synthesized macrocyclic diamide. Microchem. J. 63 (1999) 202-210
    • (1999) Microchem. J. , vol.63 , pp. 202-210
    • Shamsipur, M.1    Rouhani, S.2    Ganjali, M.R.3    Eshghi, H.4    Sharghi, H.5
  • 33
    • 0000284247 scopus 로고
    • A liquid-state copper(II) ion-selective electrode containing a complex of Cu(II) with salicylaniline
    • Ren K. A liquid-state copper(II) ion-selective electrode containing a complex of Cu(II) with salicylaniline. Talanta 36 (1989) 767-771
    • (1989) Talanta , vol.36 , pp. 767-771
    • Ren, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.