메뉴 건너뛰기




Volumn 23, Issue 3, 2008, Pages 446-450

Less Invasive Stabilization System for the Management of Periprosthetic Femoral Fractures Around Hip Arthroplasty

Author keywords

hip arthroplasty; LISS plate; periprosthetic fracture

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMORBIDITY; CONTROLLED STUDY; FEMUR FRACTURE; FOLLOW UP; FRACTURE HEALING; HIP ARTHROPLASTY; HOSPITAL DISCHARGE; HOSPITALIZATION; HUMAN; INFECTION; PROSTHESIS; TREATMENT OUTCOME;

EID: 40749107825     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2007.01.028     Document Type: Article
Times cited : (23)

References (10)
  • 1
    • 0034049783 scopus 로고    scopus 로고
    • Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem. A biomechanical study of 5techniques
    • Dennis M.G., Simon J.A., Kumer F.J., et al. Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem. A biomechanical study of 5techniques. J Arthroplasty 15 (2000) 523
    • (2000) J Arthroplasty , vol.15 , pp. 523
    • Dennis, M.G.1    Simon, J.A.2    Kumer, F.J.3
  • 2
    • 1642504433 scopus 로고    scopus 로고
    • The management of periprosthetic fractures around the femoral stem
    • Learmonth I.D. The management of periprosthetic fractures around the femoral stem. J Bone Joint Surg Br 86 (2004) 13
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 13
    • Learmonth, I.D.1
  • 3
    • 0036834933 scopus 로고    scopus 로고
    • Extra osseousblood supply of the tibia and the effects of different plating techniques: a human cadaver study
    • Borrelli J., Prickett W., Song E., et al. Extra osseousblood supply of the tibia and the effects of different plating techniques: a human cadaver study. J Orthop Trauma 16 (2002) 691
    • (2002) J Orthop Trauma , vol.16 , pp. 691
    • Borrelli, J.1    Prickett, W.2    Song, E.3
  • 4
    • 0034777725 scopus 로고    scopus 로고
    • Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures
    • Marti A., Fankhauser C., Frenk A., et al. Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures. J Orthop Trauma 15 (2001) 482
    • (2001) J Orthop Trauma , vol.15 , pp. 482
    • Marti, A.1    Fankhauser, C.2    Frenk, A.3
  • 5
    • 0036789284 scopus 로고    scopus 로고
    • Comparison of the LISS and a retrograde-inserted supracondylar intramedullary nail for fixation of a periprosthetic distal femur fracture proximal to a total knee arthroplasty
    • Bon M.R., Egol K.A., Koval K.J., et al. Comparison of the LISS and a retrograde-inserted supracondylar intramedullary nail for fixation of a periprosthetic distal femur fracture proximal to a total knee arthroplasty. J Arthroplasty 17 (2002) 876
    • (2002) J Arthroplasty , vol.17 , pp. 876
    • Bon, M.R.1    Egol, K.A.2    Koval, K.J.3
  • 6
    • 33748430483 scopus 로고    scopus 로고
    • Low complication rate of LISS for femur fractures adjacent to stable hip or knee arthroplasty
    • O'Toole R.V., Gobezie R., Hwang R., et al. Low complication rate of LISS for femur fractures adjacent to stable hip or knee arthroplasty. Clin Orthop Relat Res 450 (2006) 203
    • (2006) Clin Orthop Relat Res , vol.450 , pp. 203
    • O'Toole, R.V.1    Gobezie, R.2    Hwang, R.3
  • 7
    • 0029187931 scopus 로고
    • Fractures of the femur after hip replacement
    • Duncan C.P., and Masri B.A. Fractures of the femur after hip replacement. Instr course Lect 45 (1995) 293
    • (1995) Instr course Lect , vol.45 , pp. 293
    • Duncan, C.P.1    Masri, B.A.2
  • 8
    • 0035756974 scopus 로고    scopus 로고
    • The development of the distal femur Less Invasive Stabilisation System (LISS)
    • Frigg R., Appenzeller A., Christensen R., et al. The development of the distal femur Less Invasive Stabilisation System (LISS). Injury 32 (2001) S-C-24
    • (2001) Injury , vol.32
    • Frigg, R.1    Appenzeller, A.2    Christensen, R.3
  • 9
    • 0036600202 scopus 로고    scopus 로고
    • Peri-prosthetic femoral fractures around well fixed implants: use of cortical onlay allografts with or without a plate
    • Haddad F.S., Duncan C.P., Berry D.J., et al. Peri-prosthetic femoral fractures around well fixed implants: use of cortical onlay allografts with or without a plate. J Bone Joint Surg 84-A (2002) 945
    • (2002) J Bone Joint Surg , vol.84 -A , pp. 945
    • Haddad, F.S.1    Duncan, C.P.2    Berry, D.J.3
  • 10
    • 26044432463 scopus 로고    scopus 로고
    • Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant
    • Ricci W.M., Bolhofner B.R., Loftus T., et al. Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. J Bone Joint Surg Am 87 (2005) 2240
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 2240
    • Ricci, W.M.1    Bolhofner, B.R.2    Loftus, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.