ALGORITHM;
ARTICLE;
COMPUTER AIDED DESIGN;
ELECTRONICS;
ENERGY TRANSFER;
EQUIPMENT;
EQUIPMENT DESIGN;
EVALUATION;
INSTRUMENTATION;
METHODOLOGY;
POWER SUPPLY;
SIGNAL PROCESSING;
TRANSDUCER;
ULTRASOUND THERAPY;
ALGORITHMS;
COMPUTER-AIDED DESIGN;
ELECTRIC POWER SUPPLIES;
ELECTRONICS;
ENERGY TRANSFER;
EQUIPMENT DESIGN;
EQUIPMENT FAILURE ANALYSIS;
SIGNAL PROCESSING, COMPUTER-ASSISTED;
TRANSDUCERS;
ULTRASONIC THERAPY;
Series resonant converter with sandwich-type piezoelectric ceramic transducers
P. Fabijanski R. Lagoda Series resonant converter with sandwich-type piezoelectric ceramic transducers Proc. IEEE Int. Conf. Indus. Technol. 252 256 Proc. IEEE Int. Conf. Indus. Technol. 1996
K. Agbossou J.-L. Dion S. Carignan M. Abdelkrim A. Cheriti Class D amplifier for a power piezoelectric load IEEE Trans. Ultrason., Ferroelect., Freq. Contr. 47 1036 1041 July 2000
Low cost compact 512 channel therapeutic ultrasound system for transcutaneous ultrasound surgery
T. Hall C. Cain Low cost compact 512 channel therapeutic ultrasound system for transcutaneous ultrasound surgery Proc. 5th Int. Symp. Therapeutic Ultrasound 445 449 Proc. 5th Int. Symp. Therapeutic Ultrasound 2006-May
Megasonic transducer drive utilizing MOSFET DC-to-RF inverter with output power of 600 W at 1 MHz
T. Suzuki H. Ikeda H. Yoshida S. Shinohara Megasonic transducer drive utilizing MOSFET DC-to-RF inverter with output power of 600 W at 1 MHz IEEE Trans. Ind. Electron. 46 1159 1173 Dec. 1999
Single-ended compact MOSFET power inverter with automatic frequency control for maximizing RF output power in megasonic transducer at 3 MHz
Y. Mizutani T. Suzuki J. Ishikawa H. Ikeda H. Yoshida S. Shinohara Single-ended compact MOSFET power inverter with automatic frequency control for maximizing RF output power in megasonic transducer at 3 MHz Proc. IEEE Int. Symp. Circuits Syst. 578 581 Proc. IEEE Int. Symp. Circuits Syst. 1998
500-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls
K. Hynynen G. T. Clement N. McDannold N. Vykhodtseva R. King P. J. White S. Vitek F. A. Jolesz 500-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls Magn. Resonance Med. 52 1 100 107 July 2004
High-fidelity PWM inverter for digital audio amplification: Spectral analysis, real-time DSP implementation, and results
C. Pascual S. Zukui P. T. Krein D. V. Sarwate P. Midya W. J. Roeckner High-fidelity PWM inverter for digital audio amplification: Spectral analysis, real-time DSP implementation, and results IEEE Trans. Power Electron. 18 473 485 Jan 2003