메뉴 건너뛰기




Volumn 59, Issue 3, 2008, Pages 598-606

Gaussian process modeling for image distortion correction in echo planar imaging

Author keywords

EPI; Modeling; PSF; Undistortion

Indexed keywords

GAUSSIAN DISTRIBUTION; GAUSSIAN NOISE (ELECTRONIC); INFERENCE ENGINES; MODELS; OPTICAL TRANSFER FUNCTION; PROCESS ENGINEERING; SIGNAL TO NOISE RATIO;

EID: 40449132101     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21497     Document Type: Article
Times cited : (8)

References (22)
  • 1
    • 36149042452 scopus 로고
    • Multi‐planar image formation using NMR spin echoes
    • 1 Mansfield P. Multi‐planar image formation using NMR spin echoes. J Phys 1977 ; C10: L55–L58.
    • (1977) J Phys , vol.C10 , pp. L55-L58
    • Mansfield, P1
  • 2
    • 0025298010 scopus 로고
    • Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging
    • 2 Farzaneh F, Riederer S, Pelc NJ. Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging. Magn Reson Med 1990 ; 14: 123–139.
    • (1990) Magn Reson Med , vol.14 , pp. 123-139
    • Farzaneh, F1    Riederer, S2    Pelc, NJ3
  • 3
    • 0029034190 scopus 로고
    • Correction for geometric distortion in echo planar images from field variations
    • 3 Jezzard P, Balaban RS. Correction for geometric distortion in echo planar images from field variations. Magn Reson Med 1995 ; 34: 65–73.
    • (1995) Magn Reson Med , vol.34 , pp. 65-73
    • Jezzard, P1    Balaban, RS2
  • 4
    • 0031910857 scopus 로고    scopus 로고
    • Correction of off resonance related distortion in echo‐planar imaging using EPI‐based field maps
    • 4 Reber PJ, Wong EC, Buxton RB, Frank LR. Correction of off resonance related distortion in echo‐planar imaging using EPI‐based field maps. Magn Reson Med 1998 ; 39: 328–330.
    • (1998) Magn Reson Med , vol.39 , pp. 328-330
    • Reber, PJ1    Wong, EC2    Buxton, RB3    Frank, LR4
  • 5
    • 0032994289 scopus 로고    scopus 로고
    • Correction for EPI distortion using multi‐echo gradient echo imaging
    • 5 Chen N, Wyrwicz AM. Correction for EPI distortion using multi‐echo gradient echo imaging. Magn Reson Med 1999 ; 41: 1206–1213.
    • (1999) Magn Reson Med , vol.41 , pp. 1206-1213
    • Chen, N1    Wyrwicz, AM2
  • 6
    • 0030912558 scopus 로고    scopus 로고
    • Reduction of geometric and intensity distortions in echo‐planar imaging using a multi‐reference scan
    • 6 Xin W, Gullberg GT, Parker DL, Zeng GL. Reduction of geometric and intensity distortions in echo‐planar imaging using a multi‐reference scan. Magn Reson Med 1997 ; 37: 1206–1213.
    • (1997) Magn Reson Med , vol.37 , pp. 1206-1213
    • Xin, W1    Gullberg, GT2    Parker, DL3    Zeng, GL4
  • 7
    • 0030726765 scopus 로고    scopus 로고
    • Measurement of the point spread function in MRI using constant time imaging
    • 7 Robson MD, Gore JC, Constable RT. Measurement of the point spread function in MRI using constant time imaging. Magn Reson Med 1997 ; 38: 733–740.
    • (1997) Magn Reson Med , vol.38 , pp. 733-740
    • Robson, MD1    Gore, JC2    Constable, RT3
  • 8
    • 0036296026 scopus 로고    scopus 로고
    • Image distortion correction in EPI: comparison of field mapping with point spread function mapping
    • 8 Zeng H, Constable RT. Image distortion correction in EPI: comparison of field mapping with point spread function mapping. Magn Reson Med 2002 ; 48: 137–146.
    • (2002) Magn Reson Med , vol.48 , pp. 137-146
    • Zeng, H1    Constable, RT2
  • 9
    • 7544248836 scopus 로고    scopus 로고
    • Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo‐planar imaging distortion correction
    • 9 Zaitsev M, Hennig J, Speck O. Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo‐planar imaging distortion correction. Magn Reson Med 2004 ; 52: 1156–1166.
    • (2004) Magn Reson Med , vol.52 , pp. 1156-1166
    • Zaitsev, M1    Hennig, J2    Speck, O3
  • 10
    • 0003424741 scopus 로고    scopus 로고
    • Bayesian Gaussian processes for regression and classification, in: Doctoral dissertation
    • 10 Gibbs MN. Bayesian Gaussian processes for regression and classification. Doctoral dissertation, University of Cambridge, UK ; 1997.
    • (1997)
    • Gibbs, MN1
  • 11
    • 85120588482 scopus 로고    scopus 로고
    • Measurement of the point spread function in the MRI experiment using Fourier velocity encoding
    • 11 Robson MD, Gore JC, Constable RT. Measurement of the point spread function in the MRI experiment using Fourier velocity encoding. In: Proc ISMRM, 1996: 1287.
    • (1996) , pp. 1287
    • Robson, MD1    Gore, JC2    Constable, RT3
  • 12
    • 0033781037 scopus 로고    scopus 로고
    • Spatial resolution in echo planar imaging: shifting the acquisition window in k‐space
    • 12 Windischberger C, Moser E. Spatial resolution in echo planar imaging: shifting the acquisition window in k‐space. Magn Reson Imaging 2000 ; 18: 825–834.
    • (2000) Magn Reson Imaging , vol.18 , pp. 825-834
    • Windischberger, C1    Moser, E2
  • 13
    • 0037567878 scopus 로고    scopus 로고
    • Efficient implementation of Gaussian processes. Technical Report
    • 13 Gibbs MN, MacKay DJC. Efficient implementation of Gaussian processes. Technical Report. Cambridge, UK: Cavendish Laboratory ; 1997.
    • (1997)
    • Gibbs, MN1    MacKay, DJC2
  • 14
    • 0004272772 scopus 로고    scopus 로고
    • Information theory, inference, and learning algorithms
    • 14 MacKay DJC. Information theory, inference, and learning algorithms. Cambridge, UK: Cambridge University Press ; 2003.
    • (2003)
    • MacKay, DJC1
  • 15
    • 36849023175 scopus 로고    scopus 로고
    • Bayesian methods for machine learning
    • 15 Neal RM. Bayesian methods for machine learning. NIPS Tutorial, 13 December, 2004.
    • (2004)
    • Neal, RM1
  • 16
    • 33845323186 scopus 로고    scopus 로고
    • On the numeric stability of Gaussian processes regression for relational reinforcement learning
    • 16 Ramon J, Driessens K. On the numeric stability of Gaussian processes regression for relational reinforcement learning. In: ICML Workshop on Relational Reinforcement Learning, Banff, Canada, 2004. p 10–14.
    • (2004) , pp. 10-14
    • Ramon, J1    Driessens, K2
  • 17
    • 10044293254 scopus 로고    scopus 로고
    • New approach for correcting distortions in echo planar imaging
    • 17 Zeng H, Gatenby JC, Zhao Y, Gore JC. New approach for correcting distortions in echo planar imaging. Magn Reson Med 2004 ; 52: 1373–1378.
    • (2004) Magn Reson Med , vol.52 , pp. 1373-1378
    • Zeng, H1    Gatenby, JC2    Zhao, Y3    Gore, JC4
  • 19
    • 0032883422 scopus 로고    scopus 로고
    • Sources of distortion in functional MRI data
    • 19 Jezzard P, Clare S. Sources of distortion in functional MRI data. Hum Brain Mapp 1999 ; 8: 80–85.
    • (1999) Hum Brain Mapp , vol.8 , pp. 80-85
    • Jezzard, P1    Clare, S2
  • 20
    • 0033623981 scopus 로고    scopus 로고
    • Parametric estimate of intensity inhomogeneities applied to MRI
    • 20 Styner M, Brechbühler C, Székely G, Gerig G. Parametric estimate of intensity inhomogeneities applied to MRI. IEEE Trans Med Imaging 2000 ; 19: 153–165.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 153-165
    • Styner, M1    Brechbühler, C2    Székely, G3    Gerig, G4
  • 21
    • 0034752901 scopus 로고    scopus 로고
    • Magnetic susceptibility quantification for arbitrarily shaped objects in inhomogeneous fields
    • 21 Li L. Magnetic susceptibility quantification for arbitrarily shaped objects in inhomogeneous fields. Magn Reson Med 2001 ; 46: 907–916.
    • (2001) Magn Reson Med , vol.46 , pp. 907-916
    • Li, L1
  • 22
    • 0010902083 scopus 로고
    • Matrix methods for scientists and engineers
    • 22 Barnett S. Matrix methods for scientists and engineers. New York: McGraw‐Hill ; 1979.
    • (1979)
    • Barnett, S1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.