메뉴 건너뛰기




Volumn 20, Issue 3, 2008, Pages 130-133

Damage to polymer of undelivered sirolimus-eluting stents

Author keywords

Angioplasty; Coronary artery disease; Drug eluting stents

Indexed keywords

POLYMER; RAPAMYCIN;

EID: 40449094745     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (15)

References (11)
  • 1
    • 34547608772 scopus 로고    scopus 로고
    • Drug-eluting stent update 2007: Part I. A survey of current and future generation drug-eluting stents: Meaningful advances or more of the same?
    • Daemen J, Serruys PW. Drug-eluting stent update 2007: Part I. A survey of current and future generation drug-eluting stents: Meaningful advances or more of the same? Circulation 2007;116:316-328.
    • (2007) Circulation , vol.116 , pp. 316-328
    • Daemen, J.1    Serruys, P.W.2
  • 2
    • 0037030658 scopus 로고    scopus 로고
    • A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • Morice MC, Serruys PW, Sousa JE, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346:1773-1780.
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3
  • 3
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-1323.
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 4
    • 34948830243 scopus 로고    scopus 로고
    • Impact of drug-eluting stents on clinical and angiographic outcomes in dialysis patients
    • Ishio N, Kobayashi Y, Takebayashi H, et al. Impact of drug-eluting stents on clinical and angiographic outcomes in dialysis patients. Circ J 2007;71:1525-1529.
    • (2007) Circ J , vol.71 , pp. 1525-1529
    • Ishio, N.1    Kobayashi, Y.2    Takebayashi, H.3
  • 5
    • 12144286893 scopus 로고    scopus 로고
    • Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis
    • Fujii K, Mintz GS, Kobayashi Y, et al. Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis. Circulation 2004;109:1085-1088.
    • (2004) Circulation , vol.109 , pp. 1085-1088
    • Fujii, K.1    Mintz, G.S.2    Kobayashi, Y.3
  • 6
    • 34547669112 scopus 로고    scopus 로고
    • Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation
    • Lee SH, Park JS, Shin DG, et al. Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol 2007;100:627-630.
    • (2007) Am J Cardiol , vol.100 , pp. 627-630
    • Lee, S.H.1    Park, J.S.2    Shin, D.G.3
  • 7
    • 20844451557 scopus 로고    scopus 로고
    • Nonuniform strut distribution correlates with more neointimal hyperplasia after sirolimus-eluting stent implantation
    • Takebayashi H, Mintz GS, Carlier SG, et al. Nonuniform strut distribution correlates with more neointimal hyperplasia after sirolimus-eluting stent implantation. Circulation 2004;110:3430-3434.
    • (2004) Circulation , vol.110 , pp. 3430-3434
    • Takebayashi, H.1    Mintz, G.S.2    Carlier, S.G.3
  • 8
    • 0038034503 scopus 로고    scopus 로고
    • Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation
    • Colombo A, Orlic D, Stankovic G, et al. Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation. Circulation 2003;107:2178-2180.
    • (2003) Circulation , vol.107 , pp. 2178-2180
    • Colombo, A.1    Orlic, D.2    Stankovic, G.3
  • 9
    • 33751005294 scopus 로고    scopus 로고
    • Damage to polymer of a sirolimus-eluting stent
    • Kuriyama N, Kobayashi Y, Nakayama T, et al. Damage to polymer of a sirolimus-eluting stent. Circulation 2006;114:e586-e587.
    • (2006) Circulation , vol.114
    • Kuriyama, N.1    Kobayashi, Y.2    Nakayama, T.3
  • 10
    • 33646231229 scopus 로고    scopus 로고
    • When one won't do it, use two-double "buddy" wiring to facilitate stent advancement across a highly calcified artery
    • Jafary FH. When one won't do it, use two-double "buddy" wiring to facilitate stent advancement across a highly calcified artery. Catheter Cardiovasc Interv 2006;67:721-723.
    • (2006) Catheter Cardiovasc Interv , vol.67 , pp. 721-723
    • Jafary, F.H.1
  • 11
    • 33846804298 scopus 로고    scopus 로고
    • Facilitated stent delivery using applied topical lubrication
    • Singh A, Awar M, Ahmed A, et al. Facilitated stent delivery using applied topical lubrication. Catheter Cardiovasc Interv 2007;69:218-222.
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 218-222
    • Singh, A.1    Awar, M.2    Ahmed, A.3