메뉴 건너뛰기




Volumn 15, Issue 5, 2004, Pages 285-289

Intracoronary brachytherapy with β-radiation for the treatment of long diffuse in-stent restenosis

Author keywords

In stent restenosis; Intervention length; Intracoronary brachytherapy; Long lesions

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; STRONTIUM 90; YTTRIUM 90;

EID: 4043135930     PISSN: 09546928     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.mca.0000135403.46579.ef     Document Type: Article
Times cited : (2)

References (29)
  • 1
    • 0020702170 scopus 로고
    • Does length or eccentricity of coronary stenoses influence the outcome of transluminal dilatation?
    • Meier B, Gruentzig AR, Hollman J, Ischinger T, Bradford J. Does length or eccentricity of coronary stenoses influence the outcome of transluminal dilatation? Circulation 1983; 67:497-499.
    • (1983) Circulation , vol.67 , pp. 497-499
    • Meier, B.1    Gruentzig, A.R.2    Hollman, J.3    Ischinger, T.4    Bradford, J.5
  • 2
    • 0026563949 scopus 로고
    • Restenosis after placement of Palmaz-Schatz stents in native coronary arteries. Initial results of a multicenter experience
    • Ellis SG, Savage M, Fischman D, Baim DS, Leon M, Goldberg S, et al. Restenosis after placement of Palmaz-Schatz stents in native coronary arteries. Initial results of a multicenter experience. Circulation 1992; 86:1836-1844.
    • (1992) Circulation , vol.86 , pp. 1836-1844
    • Ellis, S.G.1    Savage, M.2    Fischman, D.3    Baim, D.S.4    Leon, M.5    Goldberg, S.6
  • 3
    • 0028200199 scopus 로고
    • Predictors of thrombotic complications after placement of the flexible coil stent
    • Agrawal SK, Ho DS, Liu MW, Iyer S, Hearn JA, Cannon AD, et al. Predictors of thrombotic complications after placement of the flexible coil stent. Am J Cardiol 1994; 73:1216-1219.
    • (1994) Am J Cardiol , vol.73 , pp. 1216-1219
    • Agrawal, S.K.1    Ho, D.S.2    Liu, M.W.3    Iyer, S.4    Hearn, J.A.5    Cannon, A.D.6
  • 4
    • 0032535286 scopus 로고    scopus 로고
    • Clinical and angiographic results of stenting for long coronary arterial atherosclerotic lesions
    • Le Breton H, Bedossa M, Commeau P, Boschat J, Huret B, Gilard M, et al. Clinical and angiographic results of stenting for long coronary arterial atherosclerotic lesions. Am J Cardiol 1998; 82:1539-1543.
    • (1998) Am J Cardiol , vol.82 , pp. 1539-1543
    • Le Breton, H.1    Bedossa, M.2    Commeau, P.3    Boschat, J.4    Huret, B.5    Gilard, M.6
  • 6
    • 0037028645 scopus 로고    scopus 로고
    • A randomized comparison of the value of additional stenting after optimal balloon angioplasty for long coronary lesions: Final results of the additional value of NIR stents for treatment of long coronary lesions (ADVANCE) study
    • Serruys PW, Foley DP, Suttorp MJ, Rensing BJ, Suryapranata H, Materne P, et al. A randomized comparison of the value of additional stenting after optimal balloon angioplasty for long coronary lesions: final results of the additional value of NIR stents for treatment of long coronary lesions (ADVANCE) study. J Am Coll Cardiol 2002; 39:393-399.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 393-399
    • Serruys, P.W.1    Foley, D.P.2    Suttorp, M.J.3    Rensing, B.J.4    Suryapranata, H.5    Materne, P.6
  • 9
    • 17944369465 scopus 로고    scopus 로고
    • The influence of stent length on clinical and angiographic outcome in patients undergoing elective stenting for native coronary artery lesions; final results of the Magic 5L Study
    • Foley DP, Pieper M, Wijns W, Suryapranata H, Grollier G, Legrand V, et al. The influence of stent length on clinical and angiographic outcome in patients undergoing elective stenting for native coronary artery lesions; final results of the Magic 5L Study. Eur Heart J 2001; 22:1585-1593.
    • (2001) Eur Heart J , vol.22 , pp. 1585-1593
    • Foley, D.P.1    Pieper, M.2    Wijns, W.3    Suryapranata, H.4    Grollier, G.5    Legrand, V.6
  • 10
    • 0034625080 scopus 로고    scopus 로고
    • Intracoronary gamma-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis (WRIST)
    • Waksman R, White RL, Chan RC, Bass BG, Geirlach L, Mintz GS, et al. Intracoronary gamma-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis (WRIST). Circulation 2000; 101:2165-2171.
    • (2000) Circulation , vol.101 , pp. 2165-2171
    • Waksman, R.1    White, R.L.2    Chan, R.C.3    Bass, B.G.4    Geirlach, L.5    Mintz, G.S.6
  • 11
    • 0035945667 scopus 로고    scopus 로고
    • Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting
    • Leon MB, Teirstein PS, Moses JW, Tripuraneni P, Lansky AJ, Jani S, et al. Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting. N Engl J Med 2001; 344:250-256.
    • (2001) N Engl J Med , vol.344 , pp. 250-256
    • Leon, M.B.1    Teirstein, P.S.2    Moses, J.W.3    Tripuraneni, P.4    Lansky, A.J.5    Jani, S.6
  • 12
    • 17544400054 scopus 로고    scopus 로고
    • Intracoronary beta-radiation therapy inhibits recurrence of in-stent restenosis (Beta-WRIST)
    • Waksman R, Bhargava B, White L, Chan RC, Mehran R, Lansky AJ, et al. Intracoronary beta-radiation therapy inhibits recurrence of in-stent restenosis (Beta-WRIST). Circulation 2000; 101:1895-1898.
    • (2000) Circulation , vol.101 , pp. 1895-1898
    • Waksman, R.1    Bhargava, B.2    White, L.3    Chan, R.C.4    Mehran, R.5    Lansky, A.J.6
  • 13
    • 0037183375 scopus 로고    scopus 로고
    • Randomized trial of 90Sr/90Y beta-radiation versus placebo control for treatment of in-stent restenosis (START)
    • Popma JJ, Suntharalingam M, Lansky AJ, Heuser RR, Speiser B, Teirstein PS, et al. Randomized trial of 90Sr/90Y beta-radiation versus placebo control for treatment of in-stent restenosis (START). Circulation 2002; 106:1090-1096.
    • (2002) Circulation , vol.106 , pp. 1090-1096
    • Popma, J.J.1    Suntharalingam, M.2    Lansky, A.J.3    Heuser, R.R.4    Speiser, B.5    Teirstein, P.S.6
  • 14
    • 0037116881 scopus 로고    scopus 로고
    • Use of localised intracoronary beta radiation in treatment of in-stent restenosis: The INHIBIT randomised controlled trial
    • Waksman R, Raizner AE, Yeung AC, Lansky AJ, Vandertie L. Use of localised intracoronary beta radiation in treatment of in-stent restenosis: the INHIBIT randomised controlled trial. Lancet 2002; 359:551-557.
    • (2002) Lancet , vol.359 , pp. 551-557
    • Waksman, R.1    Raizner, A.E.2    Yeung, A.C.3    Lansky, A.J.4    Vandertie, L.5
  • 15
    • 0037426377 scopus 로고    scopus 로고
    • Intracoronary radiation therapy improves the clinical and angiographic outcomes of diffuse in-stent restenotic lesions: Results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions (Long WRIST) Studies
    • Waksman R, Cheneau E, Ajani AE, White RL, Pinnow E, Torguson R, et al. Intracoronary radiation therapy improves the clinical and angiographic outcomes of diffuse in-stent restenotic lesions: results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions (Long WRIST) Studies. Circulation 2003; 107:1744-1749.
    • (2003) Circulation , vol.107 , pp. 1744-1749
    • Waksman, R.1    Cheneau, E.2    Ajani, A.E.3    White, R.L.4    Pinnow, E.5    Torguson, R.6
  • 16
    • 0037805073 scopus 로고    scopus 로고
    • Intracoronary beta-radiation for the treatment of patients at very high risk for recurrence of in-stent restenosis: A single center experience
    • Parenti DZ, Marsico F, Tosi G, Catalano G, Maiello L, Milone F, et al. Intracoronary beta-radiation for the treatment of patients at very high risk for recurrence of in-stent restenosis: a single center experience. Ital Heart J 2003; 4:199-204.
    • (2003) Ital Heart J , vol.4 , pp. 199-204
    • Parenti, D.Z.1    Marsico, F.2    Tosi, G.3    Catalano, G.4    Maiello, L.5    Milone, F.6
  • 17
    • 0035651456 scopus 로고    scopus 로고
    • Treatment of long, diffuse, in-stent restenotic lesions with beta radiation using strontium 90 and sequential positioning "pullback" technique: Procedural details and clinical outcomes
    • Crocker I, Joyal M, Fox T, Arsenault A, Bonan R. Treatment of long, diffuse, in-stent restenotic lesions with beta radiation using strontium 90 and sequential positioning "pullback" technique: procedural details and clinical outcomes. J Invasive Cardiol 2001; 13:782-787.
    • (2001) J Invasive Cardiol , vol.13 , pp. 782-787
    • Crocker, I.1    Joyal, M.2    Fox, T.3    Arsenault, A.4    Bonan, R.5
  • 18
    • 0036843246 scopus 로고    scopus 로고
    • Combined cutting balloon angioplasty and intracoronary beta radiation for treatment of in-stent restenosis: Clinical outcomes and effect of pullback radiation for long lesions
    • Moustapha A, Salloum J, Saikia S, Awadallah H, Ghani M, Sdringola, et al. Combined cutting balloon angioplasty and intracoronary beta radiation for treatment of in-stent restenosis: clinical outcomes and effect of pullback radiation for long lesions. Catheter Cardiovasc Interv 2002; 57:325-329.
    • (2002) Catheter Cardiovasc Interv , vol.57 , pp. 325-329
    • Moustapha, A.1    Salloum, J.2    Saikia, S.3    Awadallah, H.4    Ghani, M.5    Sdringola6
  • 19
    • 0036988966 scopus 로고    scopus 로고
    • Serial intravascular ultrasound analysis after intracoronary beta-radiation in long in-stent restenotic lesions
    • Schiele TM, Zimmermann A, Rieber J, Konig A, Krotz F, Sohn HY, et al. Serial intravascular ultrasound analysis after intracoronary beta-radiation in long in-stent restenotic lesions. Z Kardiol 2002; 91 (suppl 3):17-22.
    • (2002) Z Kardiol , vol.91 , Issue.3 SUPPL. , pp. 17-22
    • Schiele, T.M.1    Zimmermann, A.2    Rieber, J.3    Konig, A.4    Krotz, F.5    Sohn, H.Y.6
  • 20
    • 0036903893 scopus 로고    scopus 로고
    • Pathophysiology of coronary artery restenosis
    • Schwartz RS, Henry TD. Pathophysiology of coronary artery restenosis. Rev Cardiovasc Med 2002; 3 (suppl 5):4-9.
    • (2002) Rev Cardiovasc Med , vol.3 , Issue.5 SUPPL. , pp. 4-9
    • Schwartz, R.S.1    Henry, T.D.2
  • 21
    • 0033517846 scopus 로고    scopus 로고
    • Angiographic patterns of in-stent restenosis: Classification and implications for long-term outcome
    • Mehran R, Dangas G, Abizaid AS, Mintz GS, Lansky AJ, Satler LF, et al. Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome. Circulation 1999; 100:1872-1878.
    • (1999) Circulation , vol.100 , pp. 1872-1878
    • Mehran, R.1    Dangas, G.2    Abizaid, A.S.3    Mintz, G.S.4    Lansky, A.J.5    Satler, L.F.6
  • 22
    • 0037009976 scopus 로고    scopus 로고
    • Geographical miss during intracoronary irradiation: Impact on restenosis and determination of required safety margin length
    • Syeda B, Siostrzonek P, Schmid R, Wexberg P, Kirisits C, Denk S, et al. Geographical miss during intracoronary irradiation: impact on restenosis and determination of required safety margin length. J Am Coll Cardiol 2002; 40:1225-1231.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 1225-1231
    • Syeda, B.1    Siostrzonek, P.2    Schmid, R.3    Wexberg, P.4    Kirisits, C.5    Denk, S.6
  • 23
    • 0034883748 scopus 로고    scopus 로고
    • Geographical miss during catheter-based intracoronary beta-radiation: Incidence and implications in the BRIE study. Beta-Radiation in Europe
    • Sianos G, Kay IP, Costa MA, Regar E, Kozuma K, de Feyter PJ et al. Geographical miss during catheter-based intracoronary beta-radiation: incidence and implications in the BRIE study. Beta-Radiation In Europe. J Am Coll Cardiol 2001; 38:415-420.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 415-420
    • Sianos, G.1    Kay, I.P.2    Costa, M.A.3    Regar, E.4    Kozuma, K.5    De Feyter, P.J.6
  • 24
    • 0035869310 scopus 로고    scopus 로고
    • Edge stenosis and geographical miss following intracoronary gamma radiation therapy for in-stent restenosis
    • Kim HS, Waksman R, Cottin Y, Kollum M, Bhargava B, Mehran R, et al. Edge stenosis and geographical miss following intracoronary gamma radiation therapy for in-stent restenosis. J Am Coll Cardiol 2001; 37:1026-1030.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1026-1030
    • Kim, H.S.1    Waksman, R.2    Cottin, Y.3    Kollum, M.4    Bhargava, B.5    Mehran, R.6
  • 25
    • 0037022205 scopus 로고    scopus 로고
    • Rotational atherectomy does not reduce recurrent in-stent restenosis: Results of the angioplasty versus rotational atherectomy for treatment of diffuse in-stent restenosis trial (ARTIST)
    • vom Dahl J, Dietz U, Haager PK, Silber S, Niccoli L, Buettner HJ, et al. Rotational atherectomy does not reduce recurrent in-stent restenosis: results of the angioplasty versus rotational atherectomy for treatment of diffuse in-stent restenosis trial (ARTIST). Circulation 2002; 105:583-588.
    • (2002) Circulation , vol.105 , pp. 583-588
    • Vom Dahl, J.1    Dietz, U.2    Haager, P.K.3    Silber, S.4    Niccoli, L.5    Buettner, H.J.6
  • 26
    • 0035895327 scopus 로고    scopus 로고
    • Serial intravascular ultrasound analysis of the impact of lesion length on the efficacy of intracoronary gamma-irradiation for preventing recurrent in-stent restenosis
    • Ahmed JM, Mintz GS, Waksman R, Weissman NJ, Leiboff B, Pichard AD, et al. Serial intravascular ultrasound analysis of the impact of lesion length on the efficacy of intracoronary gamma-irradiation for preventing recurrent in-stent restenosis. Circulation 2001; 103:188-191.
    • (2001) Circulation , vol.103 , pp. 188-191
    • Ahmed, J.M.1    Mintz, G.S.2    Waksman, R.3    Weissman, N.J.4    Leiboff, B.5    Pichard, A.D.6
  • 27
    • 0035928754 scopus 로고    scopus 로고
    • Serial intravascular ultrasound assessment of the efficacy of intracoronary gamma-radiation therapy for preventing recurrence in very long, diffuse, in-stent restenosis lesions
    • Ahmed JM, Mintz GS, Waksman R, Mehran R, Leiboff B, Pichard AD, et al. Serial intravascular ultrasound assessment of the efficacy of intracoronary gamma-radiation therapy for preventing recurrence in very long, diffuse, in-stent restenosis lesions. Circulation 2001; 104:856-859.
    • (2001) Circulation , vol.104 , pp. 856-859
    • Ahmed, J.M.1    Mintz, G.S.2    Waksman, R.3    Mehran, R.4    Leiboff, B.5    Pichard, A.D.6
  • 28
    • 18744372115 scopus 로고    scopus 로고
    • Safety and efficacy of manual stepping and overlapping of beta-emitter for diffuse in-stent restenosis lesions
    • Kim HS, Waksman R, Chan RC, Pappas CK, Bhargava B, Ajani AE, et al. Safety and efficacy of manual stepping and overlapping of beta-emitter for diffuse in-stent restenosis lesions. Cardiovasc Radiat Med 2002; 3:56-59.
    • (2002) Cardiovasc Radiat Med , vol.3 , pp. 56-59
    • Kim, H.S.1    Waksman, R.2    Chan, R.C.3    Pappas, C.K.4    Bhargava, B.5    Ajani, A.E.6
  • 29
    • 0037454017 scopus 로고    scopus 로고
    • The outcome of percutaneous coronary intervention in patients with in-stent restenosis who failed intracoronary radiation therapy
    • Ajani AE, Waksman R, Cheneau E, Cha DH, McGlynn S, Castagna M, et al. The outcome of percutaneous coronary intervention in patients with in-stent restenosis who failed intracoronary radiation therapy. J Am Coll Cardiol 2003; 41:551-556.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 551-556
    • Ajani, A.E.1    Waksman, R.2    Cheneau, E.3    Cha, D.H.4    McGlynn, S.5    Castagna, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.